To begin searching the abstracts, use the search features on the right.

Electronic Power Pitch Poster
Weekend and Oral

Traditional Posters (no CME credit)

Electronic Posters (no CME credit)

Electronic Power Pitch Poster

Poster: Interventional/Safety/Engineering

Exhibition Hall Monday 9:15 - 10:15

1
Plasma 1
Overcoming Limitations of Virtual Observation Points in pTx using IMPULSE
Mihir Pendse1 and Brian K Rutt1

1Stanford University, Stanford, CA, United States

We analyze the performance of the IMPULSE pTx optimization algorithm, which allows SAR-aware pulse design without virtual observation points (VOP) compression. We compare performance of IMPULSE with conventional optimization methods using VOPs and compare different values of the overestimation parameter. We show that IMPULSE results in elimination of the time-intensive compression step without significantly increasing the time for real-time optimization. Additionally by eliminating the overestimation error from the VOP compression, IMPULSE is able to achieve better mitigation of local SAR hotspots after optimization than VOP-based methods.

2
Plasma 2
Optical-based probe for real time assessment of RF electrical field during MRI exam
Isabelle Saniour1, Gwenaël Gaborit2,3, Lionel Duvillaret3, Anne-Laure Perrier2, and Olivier Beuf1

1Univ. Lyon, CREATIS ; CNRS UMR 5220 ; INSERM U1206 ; INSA-Lyon ; UJM-Saint-Etienne ; Université Lyon1, Villeurbanne, France, 2Univ. Savoie-Mont-Blanc, IMEP-LAHC, Le Bourget-du-Lac, France, 3Kapteos, Sainte-Hélène-du-Lac, France

During MRI exam, Specific Absorption Rate (SAR) is essential to be controlled and can be evaluated by measuring either indirectly for instance the rise in temperature or directly the radiofrequency induced electrical E-field. In the current study, we proposed an optical probe based on the Pockels effect for subcentimeter resolution measurements of the E-field without altering the surrounding media. Measurements were performed at 4.7 T and 3.0 T. Results show that the probe has an excellent linear response and allow a real time estimate of the three components of the E-field produced during MRI examination.  

3
Plasma 3
Modeling of Peripheral Nervous Stimulation Thresholds in Realistic Body Models
Mathias Davids1,2, Bastien Guérin2,3, Lothar R Schad1, and Lawrence L Wald2,3,4

1Computer Assisted Clinical Medicine, Heidelberg University, Mannheim, Germany, 2Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, United States, 3Harvard Medical School, Boston, MA, United States, 4Harvard-MIT Division of Health Sciences Technology, Cambridge, United States

Peripheral Nervous Stimulation (PNS) has become an important limitation in MRI with the latest generation of high-performance gradient systems. We present – to our knowledge for the first time – a model to predict PNS thresholds for arbitrary coil geometries. Our model consists of an accurate body model for EM simulations, a detailed nerve atlas of the human body, and a numerical model to predict nerve responses to induced electrical fields. With this model, we were able to reproduce PNS threshold curves of two leg/arm solenoid coils that were previously evaluated experimentally. We intent to use this PNS model to design high-performance gradient coils with significantly lowered PNS capabilities.

4
Plasma 4
Cardiac Synchronization at Ultra-High Field Using a 3-Lead ECG Trigger Device
Daniel Stäb1, Juergen Roessler2, Kieran O'Brien3, Je Yen Su1, Christian Hamilton-Craig4, and Markus Barth1

1The Centre for Advanced Imaging, The University of Queensland, Brisbane, Australia, 2Siemens Healthcare GmbH, Erlangen, Germany, 3Siemens Healthcare Pty Ltd, Brisbane, Australia, 4Richard Slaughter Centre of Excellence in CVMRI, The Prince Charles Hospital, Brisbane, Australia

Accurate cardiac synchronization is essential in CMR. At ultra-high field, ECG triggering can be significantly impacted by the magneto-hydrodynamic (MHD) effect. Here, we investigate the performance of a conventional 3-lead ECG trigger device and a state-of-the-art trigger algorithm for cardiac ECG synchronization at 7 T. We show that by appropriate subject preparation and by including a learning phase for the R-wave detection outside of the magnetic field, reliable ECG triggering at ultra-high field is feasible despite severe distortions of the ECG signal. A quantitative analysis in 10 healthy subjects revealed a trigger sensitivity and specificity of 97.6% and 98.4%, respectively.

5
Plasma 5
A Combined 7 Tesla MRI/NMR Probe Head for Photochemical Applications.
Jens Groebner1, Gernot Heitmann1, Marcel Dommaschk1, Lukas M. Huber2, Eduard Stadler3, Reiner Umathum4, Frank D. Sönnichsen1, and Rainer Herges1

1Otto Diels Institute for Organic Chemistry, Kiel University, Kiel, Germany, 2Molecular Imaging North Competence Center, University Medical Center Schleswig-Holstein, Kiel, Germany, 3Institute of Physical and Theoretical Chemistry, Graz University of Technology, Graz, Austria, 4Medical Physics in Radiology, German Cancer Research Center, Heidelberg, Germany

The development of new photoswitchable contrast agents requires analysis with both NMR and MRI. In this work a combined probe head for in situ light exposure is presented which can be used on NMR and MRI systems with both 7 Tesla. A probe head with four slanted quartz rods was fabricated. A dual tuned (1H and 2H) Helmholtz coil was integrated into the probe head. NMR and MRI experiments were performed on photoswitchable solutions (e.g. contrast agents). Results show that photoswitchable solutions can be successfully switched in situ and simultaneously analyzed with NMR or imaged with MRI. 

6
Plasma 6
Evaluation of cardiac magnetic resonance thermometry in patients
Valery Ozenne1, Solenn Toupin1,2, Pierre Bour1, Baudouin Denis de Senneville3, Alexis Vaussy2, Matthieu Lepetit-Coiffé2, Pierre Jaïs4, Hubert Cochet4, and Bruno Quesson1

1Electrophysiology and Heart Modeling Institute, Bordeaux, France, 2Siemens Healthcare, Paris, France, 3Mathematical Institute of Bordeaux, Bordeaux, France, 4Department of Cardiac Electrophysiology, Hôpital Cardiologique de Haut-Lévêque, Bordeaux, France

Recent studies have proposed to monitor radiofrequency ablation on the heart using real-time MR-thermometry. Methods rely on ECG triggering which can fail in presence of arrhythmia. This study evaluates the precision of MR-thermometry on patients (N=15) even in presence of cardiac arrhythmia.  Phase images were acquired using a single-shot multi-slice echo planar imaging and temperature maps were calculated and displayed on the fly. ECG was recorded simultaneously for further analysis of cardiac rhythm and post-processing of temperature images. Stability of temperature mapping without RF-heating was evaluated in each pixel and correlated to the prevalence of arrhythmia.

7
Plasma 7
MRI-monitored Anterior Cervical Discectomy and Fusion (ACDF) surgery: Observation of intra-procedural nerve decompression during surgery
Ehud J Schmidt1, Daniel F Kacher1, Wei Wang1, Mitchel B Harris2, Thomas C Lee1, Ravi Seethamraju3, Clare M Tempany1, and Jay Zampini2

1Radiology, Brigham and Womens Hospital, Boston, MA, United States, 2Orthopedic Surgery, Brigham and Womens Hospital, Boston, MA, United States, 3MRI, Siemens Healthcare, Boston, MA, United States

ACDF is a surgical procedure performed when herniated disks produce severe pain, or arm/hand weakness. Severe complications occur in ~9% of cases, mainly due to tissue resection adjoining the spinal canal. MRI imaging, performed at several procedure stages, can visualize the extent of resection, and the degree of nerve decompression. We performed ACDF surgery on the MRI table, using an MRI-compatible tool-set. Imaging at 3T was performed at four procedure phases. Imaging disclosed significant spine decompression immediately after disk resection, with smaller changes after osteophyte and posterior longitudinal ligament removal. MRI-monitored ACDF can revise procedure phases, leading to improved outcomes.  

8
Plasma 8
Water diffusivity changes in the brain following exposure to low levels of focused ultrasound energy
Sijia Guo1, Jiachen Zhuo1, Xin Lu1, Su Xu1, and Rao Gullapalli1

1Department of Diagnostic Radiology & Nuclear Medicine, University of Maryland School of Medicine, Baltimore, MD, United States

MR-guided Focused ultrasound (MRgFUS) for neuro-interventions is gaining popularity. However, the biological effects of low level exposure on the brain tissue are less understood.  In this study, we used in-vivo MR diffusion kurtosis imaging (DKI) to measure water diffusion changes in vivo in rats at varying FUS exposure levels in the whole brain. Acoustic simulation and experimental data demonstrate more wide spread tissue diffusion changes and not just local changes with just a single exposure albeit for varied duration. Our results suggest that diffusion changes are mainly due to shearing forces exerted on the brain.

9
Plasma 9
Low Rank plus Sparse Compressed Sensing Reconstruction for PRF Temperature Imaging
Zhipeng Cao1,2, Sumeeth V. Jonathan2,3, and William A. Grissom1,2

1Biomedical Engineernig, Vanderbilt University, Nashville, TN, United States, 2Institute of Imaging Science, Vanderbilt University, Nashville, TN, United States, 3Radiology, Vanderbilt University, Nashville, TN, United States

A novel compressed sensing reconstruction method based on L+S separation on complex difference image domain data is demonstrated to perform better than existing methods on major applications in RF heating monitoring and MR guided focused ultrasound intervention.

10
Plasma 10
2D Multi-Spectral Thermometry for Monitoring Focused-Ultrasound Sonications Near Metallic Hardware
Hans Weber1, Pejman Ghanouni1, Aurea Pascal-Tenorio2, Kim Butts Pauly1, and Brian A. Hargreaves1

1Radiology, Stanford University, Stanford, CA, United States, 2Comparative Medicine, Stanford University, Stanford, CA, United States

The lack of a technique for MR thermometry near metallic hardware excludes a growing patient population from MR-guided focused ultrasound treatments. In this work, we explore the temperature-induced signal change in fast two-dimensional multi-spectral imaging for monitoring sonications near metallic hardware. We demonstrate initial feasibility in phantom and ex vivo experiments as well as a patient treatment.

11
Plasma 11
Toward individualized specific absorption rates: Building a surface-based human head model
Mikhail Kozlov1, Benjamin Kalloch1,2, Pierre-Louis Bazin1, Mario Hlawitschka2, Nikolaus Weiskopf1, and Harald E Möller1

1Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany, 2Leipzig University of Applied Science, Leipzig, Germany

We built a prototype of a high resolution surface-based human head model that can be simulated in a reasonable time and evaluated the influence of cerebrospinal fluid (CSF) on field propagation estimates of traveling wave excitation at 297.2 and 400 MHz. Combining neighboring triangular faces located in the same plane into a single one is an approach that achieves simulations of high-resolution human models previously not accessible to tetrahedral-mesh-based solvers. If electrical contact between anatomically connected parts of CSF is correctly considered, CSF was found to partially shield brain tissues from the incident RF field.

12
Plasma 12
Patient specific modeling of deep brain stimulation patients for MRI safety studies
Bastien Guerin1,2, Peter Serano3,4, Maria I Iacono3, Todd Herrington2,5, Alik Widge2,6, Darin Dougherty2,6, Giorgio Bonmassar1,2, Leonardo M Angelone3, and Lawrence Wald1,2

1Radiology, Massachusetts General Hospital, Charlestown, MA, United States, 2Harvard Medical School, Boston, MA, United States, 3Division of Biomedical Physics, OSEL, CDRH, US Food and Drug Administration, Silver Spring, MD, United States, 4Mechanical Engineering, University of Maryland, College Park, MD, United States, 5Neurology, Massachusetts General Hospital, MA, United States, 6Psychiatry, Massachusetts General Hospital, MA, United States

We propose a semi-automatic processing pipeline for the generation of realistic radiofrequency models of deep brain stimulation (DBS) patients. The whole process takes ~72 hours for model generation and field computation and models the exact DBS path, without intersections, the internal structure of the implant and the patient’s anatomical structures (e.g., brain, bones, muscles, lungs). We show that simplification of the DBS implant model results in high (up to 75%) differences in the estimation of energy absorption. The proposed framework allows for fast and precise modeling, which may be needed, pending experimental validation, to evaluate MRI RF-induced heating.

13
Plasma 13
Interventional Magnetic Resonance Imaging Guided Carotid Embolectomy using a Novel MRI-Conditional Resonant Catheter: Demonstration of Preclinical Feasibility
Jeffrey K. Yang1, Andre Cote1, Caroline D. Jordan1, Aaron Losey1, David McCoy1, Andrew Chu2, Jay F. Yu1, Teri Moore1, Carol Stillson1, Fabio Settecase1, Matthew D. Alexander1, Andrew Nicholson1, Mariam Aboian1, Daniel L. Cooke1, Maythem Saeed1, Dave Barry2, Alastair J. Martin1, Mark W. Wilson1, and Steven W. Hetts1

1Department of Radiology and Biomedical Imaging, UCSF, San Francisco, CA, United States, 2Penumbra Inc, Alameda, CA, United States

MR-guided endovascular interventions can provide real-time imaging biomarkers for procedures such as stroke embolectomy. The purpose of this study is to determine preclinical feasibility and efficacy of imaging wireless resonant circuits embedded in a MR compatible catheter system for in vivo MR-guided carotid embolectomy in porcine stroke models. The resonant catheter system performed effectively under real-time MRI with recanalization rates (TICI 2b/3) similar to reported clinical rates in stroke embolectomy. Qualitative physiologic measures of flow under MRI were comparable to those measured under X-ray, demonstrating feasibility of resonant catheter system for in vivo carotid occlusion and embolectomy under real-time MRI.

14
Plasma 14
Acousto-optic Based Active MRI Marker for Interventional MRI Devices
Yusuf Samet Yaras1, Sarp Satir1, Cagla Ozsoy2, Rajiv Ramasawmy3, Adrienne E Campbell-Washburn3, Anthony Faranesh3, Robert Lederman3, Ozgur Kocaturk2, and Levent Degertekin1

1G.W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, United States, 2Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey, 3Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, United States

Conspicuous and safe MR markers are essential for tracking interventional MRI devices. The RF induced heating on long conductors used in current active MR markers presents a safety risk. In this work, a novel acousto-optic active MR marker with optical fiber connection is proposed to eliminate RF induced heating. The proposed marker consists of a miniature coil coupled to a piezoelectric transducer which in turn modulates the reflected light in the optical fiber. The linearity of the acousto-optic active marker with flip angle is characterized and initial in vitro imaging experiments are performed demonstrating marker visibility under MRI.

15
Plasma 15
MRI based RF safety characterization of implants using the implant response matrix: a simulation study.
Janot P. Tokaya1, Alexander J.E. Raaijmakers2,3, Peter R. Luijten2, and Cornelis A.T. van den Berg1

1Radiotherapy, UMC Utrecht, Utrecht, Netherlands, 2Radiology, UMC Utrecht, Utrecht, Netherlands, 3Biomedical Image Analysis, Eindhoven University of Technology, Netherlands

We introduce a general description of the RF response of an implant, defined as the implant response matrix (IRM). An analytical expression for the IRM is derived through basis functions that depend on a limited number of parameters. This analytical model is validated with a simulation study (Pearson correlation coefficients with simulations R: 0.9979-0.9996). This description allows a significant reduction in unknowns enabling IRM assessment by MRI measurements without hardware modifications to scanner or implant. The feasibility of MRI based IRM/TF measurement is shown in silico. With the simulated complex B1+ fields the IRM is accurately reconstructed (R: 0.974). 


Electronic Power Pitch Poster

Poster: 7T Neuroimaging

Exhibition Hall Monday 9:15 - 10:15

16
Plasma 16
The effects of B1+ correction of MP2RAGE on estimating cortical thickness and T1 at 7T
Roy Haast1, Dimo Ivanov1, Elia Formisano1, and Kâmil Uludağ1

1Department of Cognitive Neuroscience, Maastricht University, Maastricht, Netherlands

B1+ inhomogeneities can significantly affect the quantitative T1 values derived from MP2RAGE data and also automatic tissue classification, in particular in the inferior temporal and frontal lobes. Here, we investigated the effects of post-hoc correction at 7T on the T1 and apparent cortical thickness using a B1+ map for the residual transmit inhomogeneities in MP2RAGE data. We found that B1+ correction reduces these inhomogeneities leading to (1) a lower inter-subject variability, (2) enhanced localization of the GM-CSF border and (3) more accurate cortical thickness measurements.

17
Plasma 17
The relationship between cortical myeloarchitecture and functional connectivity in the human brain
Olivier E. Mougin1, Benjamin A.E. Hunt1, Prejaas K. Tewarie1, Nicolas Geades1, Peter G. Morris1, Matthew J. Brookes1, and Penny A. Gowland1

1Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, United Kingdom

The human brain relies upon the dynamic formation and dissolution of functional networks to support ongoing cognition. The goal of this study is to establish a relationship between functional and structural networks. Using ultra-high field MRI, structural network defined by grey matter myelination is measured via quantitative Magnetization Transfer. Magnetoencephalography (MEG) was used to elucidate functional networks representing the major electrophysiological pathways of communication in the brain. Our study sheds new light on the way in which cortical microstructure supports functional networks. 

18
Plasma 18
Towards in vivo spinal cord cyto- and myelo-architecture deciphering using multi-modal MRI parcellation at 7T
Manuel Taso1,2,3, Aurélien Massire1,2,3, Pierre Besson1,2, Arnaud Le Troter1,2, Maxime Guye1,2, Jean-Philippe Ranjeva1,2,3, and Virginie Callot1,2,3

1CRMBM, Aix-Marseille Univ, CNRS, Marseille, France, 2Pôle d'imagerie médicale, Hôpital de la Timone, CEMEREM, AP-HM, Marseille, France, 3iLab-Spine international associate laboratory, Marseille/Montréal, France

Ultra-high-field MRI offers exciting perspectives for the in vivo structural characterization of central nervous system tissues. Based on high-resolution multi-parametric imaging at 7T, this preliminary work focuses on the generation of new spinal cord (SC) templates, hence proposing a high-resolution T2*-w MR average with exquisite anatomical details. Parcellation of the SC substructures into individual WM tracts and motoneurone clusters was also investigated using classification methods and multimodal data (T1/T2*/DTI). Preliminary promising results revealed some insights in the underlying SC cyto- and myelo-architecture. Future developments will extend to the whole cervical cord, holding tremendous promises for studying more specific pathophysiological impairments.

19
Plasma 19
7T Quantitative Magnetization Transfer (qMT) of Cortical Gray Matter in Multiple Sclerosis Correlates with Cognitive Disability
Lydia McKeithan1,2, Bailey D. Lyttle2,3, Bailey A. Box2,3, Kristin P. O'Grady2,3, Richard D. Dortch1,2,3, Benjamin N. Conrad2, and Seth A. Smith1,2,3,4

1Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, United States, 2Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, 3Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, 4Department of Opthamology, Vanderbilt University Medical Center, Nashville, TN

Cognitive impairment (CI) is a major manifestation of multiple sclerosis (MS) and is responsible for extensively hindering patient quality of life.1 Cortical gray matter damage is critical to CI, but is poorly characterized by conventional MRI. We employed advanced methods by evaluating SIR-qMT-derived indices for differences between MS patients and healthy volunteers at 7T and derived associations with neuropsychological measures of cognitive impairment. We found significant reduction in kmf in cGM of MS patients, unique association with EDSS score, and strong correlation with cognitive performance indicating that kmf may be a significant biomarker of GM damage in MS.

20
Plasma 20
Changes in structural network connectivity in early-stage multiple sclerosis are associated with cortical demyelination
Atef Badji1,2, Gabriel Mangeat1,3, Russell Ouellette3,4, Constantina Andrada Treaba3,4, Tobias Granberg3,4,5, Elena Herranz3,4, Celine Louapre3,4, Nikola Stikov1,6, Jacob Sloane4,7, Pierre Bellec 2, Caterina Mainero3,4, and Julien Cohen-Adad1,2

1NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montreal, Montreal, QC, Canada, 2Functional Neuroimaging Unit, CRIUGM, Université de Montréal, Montreal, QC, Canada, 3Athinoula A. Martinos Center for Biomedical Imaging, MGH, 4Harvard Medical School, 5Department of Clinical Science, Intervention and Technology, Karolinska Institutet, 6Montreal Health Institute, 7Beth Israel Deaconess Medical Center

Cortical disruption and changes in brain connectomics in multiple sclerosis have been recently investigated; however, the relationship between both processes in early disease remains uncertain. We propose an integrative framework that combines diffusion-based graph theory with high-resolution quantitative T1 and T2* at 7 Tesla to investigate the topological alterations of both structural connectomics and cortical demyelination. We found that both cortical myelin loss and increase in brain connectivity were present in early MS, and that the two processes were spatially anti-correlated.  This suggests that the increase in brain connectivity in early MS could represent an adaptative role against initial, mild cortical demyelination, though this would be lost with more severe cortical disease.

21
Plasma 21
3D magnetic resonance spectroscopic imaging at 7 Tesla of patients with medically refractory focal epilepsy with non-lesional or inconclusive clinical MRIs: First Results
Rebecca Emily Feldman1, Madeline Cara Fields2, Bradley Neil Delman3, Lara Vanessa Marcuse4, and Priti Balchandani1

1Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, United States, 2Department of Neurology, Mount Sinai Hospital, New York, NY, United States, 3Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, United States, 4Department of Neurology, Mount Sinai Hospital

SASSI is a B1-insensitive, low-SAR 7T MRSI technique with reduced chemical shift localization errors. We used 3D SASSI to image the hippocampi of patients with medically refractory focal epilepsy who had non-lesional or inconclusive  clinical MRIs. Using SASSI at 7T, we detected decreases in the hippocampal NAA/Cr ratios in suspected temporal lobe epilepsy patients, on the same side as the seizure onset zones and/or 7T structural findings. 

22
Plasma 22
The value of 7T in the clinical evaluation of epileptic patients with focal cortical dysplasia
Kaibao Sun1,2, Xueyuan Wang3, Zhongwei Chen1,2, Chang Liu3, Jianfei Cui4, Zhentao Zuo1, Rong Xue1,2, Yan Zhuo1, Lin Chen1,2, Shuli Liang4, Tao Yu3, and Bo Wang1

1State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, People's Republic of China, 2University of Chinese Academy of Sciences, Beijing, People's Republic of China, 3Xunanwu Hospital Capital Medical University, Beijing, People's Republic of China, 4Chinese PLA general hospital, Beijing, People's Republic of China

Focal cortical dysplasia (FCD) is defined as topical malformations of cortical development and often results in intractable epilepsy. However, many epileptic patients with FCD have not been diagnosed because of the lack of high-quality magnetic resonance imaging. 7T MRI, in comparison with 3T, is assessed in this study to allow better characterization of lesion details and detect previously unrevealed FCD abnormalities. The results of comparison were classified for an accurate and appropriate appraisal.

23
Plasma 23
Individualized Tractography-Based Parcellation of the Globus Pallidus Pars Interna using 7T MRI in patients with Parkinson’s Disease Prior to DBS Surgery
Rémi Patriat1, Yuval Duchin1, Christophe Lenglet1, Joshua Aman2, Scott Cooper2, Jerrold Vitek2, and Noam Harel1

1CMRR / Radiology, University of Minnesota, Minneapolis, MN, United States, 2Neurology, University of Minnesota, Minneapolis, MN, United States

The success of deep brain stimulation (DBS) surgeries for Parkinson’s disease relies on the accurate placement of an electrode within the motor portion of subcortical brain targets. We use 7T MR-tractography to visualize the functional territories of the Globus Pallidus pars Interna. We found that the motor territory is located immediately posteromedially to the associative and limbic territories, akin to the subthalamic nucleus organization. This pattern was reproducible across two DBS patients. These findings shed new light on the functional organization of DBS targets, showing potential for providing valuable information to clinicians for targeting decisions and ultimately enhancing patient’s outcomes.

24
Plasma 24
Assessment of cerebral vascular abnormalities in Huntington’s Disease at 7Tesla
Richard J Dury1, Sarah L Mason2, Francesca Cicchetti3, Janelle Drouin-Ouellet2, Roger A Barker2, Penny A Gowland1, and Susan T Francis1

1Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham, United Kingdom, 2John van Geest Centre for Brain Repair, University of Cambridge, Cambridge, United Kingdom, 3Département de Psychiatrie & Neurosciences, Université Laval, QC, Canada

Huntington’s Disease (HD) is associated with vascular abnormalities and breakdown in the blood-brain barrier (BBB). Here, we use high spatial resolution time-of-flight magnetic resonance angiography (TOF-MRA) and arterial spin labelling (ASL) to assess vascular abnormalities in HD patients. We develop a pipeline to estimate vessel radii and distribution from TOF-MRA data. A significant decrease in the fractional vessel volume and a higher frequency of narrow vessels (0.15-0.45mm radius) was evident in HD patients compared to healthy volunteers across a number of cortical areas. No significant difference was found in cortical perfusion between the HD patients and healthy volunteers.

25
Plasma 25
7T TOF-MRA Shows Different Patterns of Perforating Artery in Patients with Intracranial Atherosclerosis Disease (ICAD) and Cerebral Autosomal-Dominant Arteriopathy with Subcortical Infarcts and Leukoencephalopathy (CADASIL)
Qingle Kong1,2, Qi Yang3,4, Zhaoyang Fan3, Xianchang Zhang1,2, Yun Yuan5, Xiaojing Fang5, Jing An6, Yan Zhuo1, and Zihao Zhang1

1State Key Laboratory of Brain and Cognitive Science, Beijing MR Center for Brain Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, People's Republic of China, 2University of Chinese Academy of Sciences, Beijing, People's Republic of China, 3Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States, 4Xuanwu Hospital, Beijing, People's Republic of China, 5Department of Neurology, Peking University First Hospital, Beijing, People's Republic of China, 6Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, People's Republic of China

7T high-resolution TOF-MRA has the ability to image perforating arteries of middle cerebral artery (MCA). The distribution patterns of orifices in CADASIL (cerebral autosomal-dominant arteriopathy with subcortical infarcts and leukoencephalopathy) and ICAD (intracranial atherosclerosis disease) patients are still unclear. In this study, for the first time, we investigated the orientation distribution of perforating artery orifices on MCA trunks using 7T TOF-MRA. Specific features are found in the distribution patterns of orifices in patients with CADASIL, ICAD and healthy volunteers. This technique is promising in the pathological studies of intracranial vascular diseases.

26
Plasma 26
Intracranial vessel wall imaging in suspected cerebral vasculitis: evaluation of diagnostic value and treatment effects using 3T and 7T MRI
Nikki Dieleman1, Anja G. van der Kolk1, Catharina J.M. Frijns2, Anita A. Harteveld1, Jaco J.M. Zwanenburg1, Hugo J. Kuijf3, Arjen Lindenholz1, L. Jaap Kappelle2, Peter R. Luijten1, and Jeroen Hendrikse1

1Radiology, University Medical Center Utrecht, Utrecht, Netherlands, 2Neurology, University Medical Center Utrecht, Utrecht, Netherlands, 3Images Science Institute, University Medical Center Utrecht, Utrecht, Netherlands

Cerebral vasculitis is a rare, but devastating disease that can lead to severe disability or death. Diagnosis is rather challenging, but for treatment purposes, an accurate diagnosis is crucial since different, more aggressive therapy is needed compared with non-inflammatory diseases. In the current study, we investigated the diagnostic value of intracranial vessel wall MRI at 3T and 7T in patients who were suspected of cerebral vasculitis. Our results show that intracranial vessel wall imaging at 3T and 7T MRI should be considered a promising non-invasive diagnostic tool to identify wall enhancement in patients with a suspicion of cerebral vasculitis.

27
Plasma 27
Detection of intracranial vessel wall lesions using 7T MRI: patients with posterior circulation ischemia versus healthy controls
Anita A. Harteveld1, Anja G. van der Kolk1, H. Bart van der Worp2, Nikki Dieleman1, Peter R. Luijten1, Jaco J.M. Zwanenburg1, and Jeroen Hendrikse1

1Radiology, University Medical Center Utrecht, Utrecht, Netherlands, 2Neurology and Neurosurgery, University Medical Center Utrecht, Utrecht, Netherlands

In this study presence and distribution of vessel wall lesions within the intracranial arteries of patients with recent posterior circulation ischemia and matched asymptomatic volunteers were assessed, using intracranial vessel wall MRI at 7T. Overall, vessel wall lesion presence and distribution were comparable between both groups. On arterial segment level, patients showed significantly higher lesion burden in the posterior cerebral artery, suggesting an association between posterior circulation lesion burden and ischemic events. Furthermore, a large amount of lesions showed contrast-enhancement, while the percentage of enhancing lesions was highest in the posterior circulation of the patient group.

28
Plasma 28
Metabolic differences between asymptomatic C9orf72 carriers and non-carriers assessed by brain 7T MRSI.
Henk-Jan Westeneng1, Carrie Wismans1, Abram D. Nitert1, Renée Walhout1, Peter R. Luijten2, Jannie P. Wijnen2, and Leonard H. van den Berg1

1Department of Neurology, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, Netherlands, 2Department of Radiology, University Medical Center Utrecht, Utrecht, Netherlands

Amyotrophic lateral sclerosis (ALS) is an incurable and fatal neurodegenerative disease, which is caused by a C9orf72 repeat expansion in 9% of the cases. This mutation may cause changes of brain metabolism in patients but whether it affects brain metabolism in pre-symptomatic mutation carriers was not studied before. We used 7 Tesla magnetic resonance spectroscopic imaging (MRSI) to study brain metabolism in asymptomatic carriers of the C9orf72 repeat expansion and found lower concentrations of glutamate and N-acetylaspartate+N-acetylaspartylglutamate in the left putamen compared to non-carriers. This might indicate asymptomatic neuronal loss, a developmental defect or possibly a protective mechanism against ALS.

29
Plasma 29
GABA and glutamate in children with Tourette Syndrome: a 7T 1H-MRS study
Nicolaas AJ Puts1,2, Richard AE Edden1,2, Matthew Ryan3, E Mark Mahone3,4, and Harvey S Singer5

1Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University, Baltimore, MD, United States, 2FM Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, United States, 3Department of Neuropsychology, Kennedy Krieger Institute, Baltimore, MD, United States, 4Department of Psychiatry and Behavioral Sciences, The Johns Hopkins University, Baltimore, MD, United States, 5Department of Neurology, The Johns Hopkins University, Baltimore, MD, United States

Studies have suggested that altered inhibition and excitation contribute to the pathology of Tourette syndrome, especially in cortical-striatal-thalamo-cortical (CSTC) pathways. GABA and glutamate were measured at 7T in large cohorts of healthy children and children with TS in regions of the CSTC network. GABA and glutamate were increased in the striatum. Glutamate was increased in the premotor region and correlated with reduced motor inhibition. These data support involvement of habitual behavioral pathways in TS. Historically the dopaminergic system has been considered to have a dominant role in TS; however, accumulating evidence strongly suggests involvement of GABA and glutamate neurotransmitter systems. 

30
Plasma 30
Multi-Parametric MRI at 7 T Enables Differentiation of MS and Age-Related White Matter Lesions
Zahra Hosseini1,2, David A. Rudko3, Jacob A. Matusinec4, Marcelo kremenchutzky 5, Ravi Menon2,6, and Maria Drangova1,6,7

1Biomedical Engineering Graduate Program, University of Western Ontario, London, ON, Canada, 2Imaging Research Laboratories, Robarts Research Institute, London, ON, Canada, 3Montreal Neurological Hospital and Institute, McGill University, Montreal, QC, Canada, 4Medicine, Schulich School of Medicine & Dentistry, University of Western Ontario, London, ON, Canada, 5Department of Clinical Neurological Sciences, Schulich School of Medicine & Dentistry, University of Western Ontario, London, ON, Canada, 6Department of Medical Biophysics, University of Western Ontario, London, ON, Canada, 7Imaging Research Laboratories, Robarts Research Institute

MRI enables visualization of white matter lesions associated with demyelination in multiple sclerosis (MS). However, subtle white matter hyperintensities are also a sign of normal aging. This study used information collected from multiple 7T MRI contrasts at baseline and four-month follow-up time points to compare signal changes in lesions of five MS patients to those of age-related lesions (ARLs) in five healthy controls.


Electronic Power Pitch Poster

Poster: Body MRI Quantitative

Exhibition Hall Monday 14:45 - 15:45

112
Plasma 1
Accelerated Segmented Diffusion-Weighted Prostate Imaging for Higher Resolution, Higher Geometric Fidelity, and Multi-b Perfusion Quantification
Pelin Aksit Ciris1, Jr-yuan George Chiou2, Daniel Glazer2, Shelley Hualei Zhang2, Tzu-Cheng Chao3, Bruno Madore2, and Stephan Ernst Maier2,4

1Department of Biomedical Engineering, Akdeniz University, Antalya, Turkey, 2Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, United States, 3Department of Computer Science, National Cheng Kung University, Tainan City, Taiwan, 4University of Gothenburg, Gothenburg, Sweden

An accelerated multi-shot diffusion imaging scheme was developed for prostate imaging. Its robustness to regularization was evaluated. Two-fold improvement in spatial resolution and over three-fold improvement in geometric fidelity were obtained as compared to single-shot EPI, in twenty-five prostate cancer patients. In contrast to the standard protocol, which involves separate scans with high (b=1400 and 0 s/mm2) and intermediate (b=500 and 0 s/mm2) diffusion weighting, the proposed accelerated protocol extended b-factor coverage to yield an additional 8 b-factors and enabled multi-b perfusion quantification in half the scan time (5 min 43 s vs. 11 min 48 s). 

113
Plasma 2
Towards validation and non-invasive interrogation of the hypoxia-driven insulin resistance hypothesis
Scott Charles Beeman1, Gordon Smith2, Joel Richard Garbow1, and Joseph JH Ackerman1,3

1Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, MO, United States, 2Department of Medicine, Washington University in St. Louis, St. Louis, MO, United States, 3Department of Chemistry, Washington University in St. Louis

Insulin resistance is a defining feature of type 2 diabetes – a disease associated with severe morbidities and mortality. Recent studies have suggested that adipose tissue hypoxia is a major common pathway to systemic insulin resistance. The goals of this work are to: (i) directly observe evidence of the hypoxia-driven insulin resistance hypothesis in human subjects via gold-standard invasive pO2 measures and (ii) establish an R1-based pO2 metric for future non-invasive studies of adipose pO2 in metabolic disease. Herein, we report initial progress towards these goals.

114
Plasma 3
Measuring temperature in brown adipose tissue using the proton chemical shift
Clemens Diwoky1, Renate Schreiber1, and Rudolf Zechner1

1Institute of Molecular Biosciences, University of Graz, Graz, Austria

Within this work an approach based on the temperature dependence of the proton resonance frequency (PRF) of water and methylene bound protons is followed to monitor in-vivo thermogenesis in the interscapular brown adipose tissue (iBAT) of mice. Measuring the change in chemical shift difference of water and fat rather than water alone, known problems of PRF-based temperature measurements such as magnetic field drift and the temperature dependence of magnetic susceptibility are circumvented. The study determines the temperature coefficient in ex-vivo iBAT tissue extracts and presents the application of the technique in measuring norepinephrine stimulated in-vivo iBAT thermogenesis.

115
Plasma 4
Development of a Noninvasive Beta Cell Functional Assay Using a Novel Zinc-Sensitive MRI Contrast Agent in Non-Human Primates
Catherine D. G. Hines1, Veronica Clavijo-Jordan2,3, Liza T Gantert1, Stacey Conarello4, Christian Preihs2,5, Sarah Chirayil2, Rachel Ortiga4, Shu-An Lin1, Michael Klimas6, A. Dean Sherry2,3,5,7, and Jeff Evelhoch6

1Translational Imaging Biomarkers, Merck Research Laboratories, West Point, PA, United States, 2Advanced Imaging Research Center, The University of Texas Southwestern Medical Center, Dallas, TX, United States, 3Radiology, The University of Texas Southwestern Medical Center, Dallas, TX, United States, 4Pharmacology, Merck Research Laboratories, West Point, PA, United States, 5VitalQuan, LLC, Dallas, TX, United States, 6Translational Biomarkers, Merck Research Laboratories, West Point, PA, United States, 7Chemistry, The University of Texas at Dallas, Richardson, United States

Pancreatic beta cells secrete insulin to maintain normal blood glucose levels, and the integrity and function of pancreatic beta cells have been found to be compromised in Type-1 and Type-2 diabetes. Therefore, non-invasive beta cell function measurements may provide valuable information for improving diabetes diagnostics and disease management. Currently available diabetes assays lack functional information and spatial identification of properly functioning beta cells. In this work, we introduce a new assay to assess the function and identify functional beta cells in vivo in the non-human primate pancreas non-invasively with MRI using a Gd-based zinc sensor as contrast agent.   

116
Plasma 5
Feasibility of Estimating Placental Oxygen Metabolism in Pregnant Women $$$in$$$ $$$vivo$$$: Initial Experience
Ana E Rodríguez-Soto1, Michael C Langham1, Nadav Schwartz2, and Felix W Wehrli1

1Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States, 2Department of Obstetrics and Gynecology, Division of Maternal-Fetal Medicine, University of Pennsylvania, Philadelphia, PA, United States

The development of methods to assess placental oxygen metabolism would allow to clinically evaluate its function. Here, we evaluated the feasibility of estimating oxygen extraction and blood flow in some abdominal and fetal draining veins. Ovarian veins appear to play an important role in draining blood from the uterus in the supine position, where flow increased from the 2nd to 3rd trimester (16.4±8.1 versus 34.3±4.1mL/min/100g). Additionally, elevation of oxygen saturation (61.6±6.6% versus 68.3±5.0%) at the umbilical vein occurred from the 2nd to 3rd trimester, potentially reflecting increased fetal oxygen demand as pregnancy progresses.  

117
Plasma 6
Free-breathing R2* Characterization of the Placenta During Normal Early Gestation Using a Multiecho 3D Stack-of-Radial Technique
Tess Armstrong1,2, Dapeng Liu1, Thomas Martin1,2, Alto Stemmer3, Yutaka Natsuaki4, Sherin U. Devaskar5, Carla Janzen6, Teresa Chanlaw5, Rinat Masamed1, Daniel Margolis7, Kyunghyun Sung1,2, and Holden H. Wu1,2

1Radiological Sciences, University of California Los Angeles, Los Angeles, CA, United States, 2Physics and Biology in Medicine, University of California Los Angeles, Los Angeles, CA, United States, 3Siemens Healthcare GmbH, Erlangen, Germany, 4Siemens Healthcare, Los Angeles, CA, United States, 5Pediatrics, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States, 6Obstetrics and Gynecology, David Geffen School of Medicine at UCLA, Los Angeles, CA, United States, 7Radiology, Weill Cornell Medical College, New York, NY, United States

Abnormal placental vascular development leads to ischemic-hypoxia thereby causing fetal growth restriction, preterm labor, and spontaneous abortion. Multiecho Cartesian MRI can characterize placental hypoxia by quantifying R2*, but is susceptible to motion artifacts. We have developed a new free-breathing (FB) multiecho R2* quantification technique using 3D stack-of-radial imaging (Radial). In n=16 subjects as part of an IRB-approved study, we observed an R2* range of 5 – 30s-1 at 3 T using the new FB Radial technique in the placenta during early normal gestation. Our new technique and the measured normative range of R2* may improve management of pregnancies with placental ischemic-hypoxia.

118
Plasma 7
Respiratory $$$\alpha$$$-mapping of cystic fibrosis at 1.5T
Orso Pusterla1,2, Grzegorz Bauman1,2, Sylvia Nyilas3, Philipp Madörin1, Bernd Jung4, Michael Ith4, Enno Stranzinger4, Urs Frey5, Philipp Latzin3, and Oliver Bieri1,2

1Department of Radiology, Division of Radiological Physics, University of Basel Hospital, Basel, Switzerland, 2Department of Biomedical Engineering, University of Basel, Basel, Switzerland, 3Division of Respiratory Medicine, Department of Pediatrics, University Children's Hospital of Bern, Bern, Switzerland, 4University Institute for Diagnostic, Interventional and Pediatric Radiology, Bern University Hospital, Bern, Switzerland, 5Department of Pediatric Pneumology, University Children's Hospital Basel, Basel, Switzerland

Respiratory $$$\alpha$$$-mapping is based on native 1H multi-volumetric ultra-fast balanced steady-state free precession (ufSSFP) breath-hold imaging of the lung and provides whole lung isotropic pulmonary ventilation-related information. In this work, respiratory $$$\alpha$$$-mapping is evaluated in pediatric patients with cystic fibrosis (CF) and compared to functional lung parameters from nitrogen multiple-breath washout (N2-MBW). The percentage of respiratory $$$\alpha$$$-impairments measured with $$$\alpha$$$-mapping is strongly correlated with the lung clearance index (LCI), a parameter for global ventilation inhomogeneity.

119
Plasma 8
5D MRI for late enhancement dynamics in lung fibrosis
Maria Teodora Antuaneta Buzan1,2, Julien Dinkel3, Christopher Rank4, Claus Peter Heussel2, Marc Kachelrieß 4, Robert Grimm5, and Andreas Wetscherek4,6

1Department of Radiology, Papworth Hospital NHS Foundation Trust, Cambridge, United Kingdom, 2Department of Diagnostic and Interventional Radiology with Nuclear Medicine, Thoraxklinik at Heidelberg University Hospital, Heidelberg, Germany, 3Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, Munich, Germany, 4Medical Physics in Radiology, German Cancer Research Center, Heidelberg, Germany, 5Siemens Healthcare, Erlangen, Germany, 6Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom

We analyzed the contrast agent late dynamics in fibrotic lung lesions of different severity, assessed with perfusion MRI, using a 5D reconstruction (respiratory 4D at different time points) of a 3D radial stack-of-stars spoiled gradient echo sequence with golden-angle spacing acquired in free-breathing. Idiopathic pulmonary fibrosis (IPF) shows late peak enhancement regardless of severity level and possibly no wash-out within the scan interval, while non-IPF lesions have faster time to peak and slower accumulation rate with increasing severity. The method might prove useful for a more thorough characterization of lung fibrosis burden in the context of new anti-fibrotic treatments available.

120
Plasma 9
Quantification of short-T2* Signal Components in the Liver using Radial 3D UTE Chemical Shift-Encoded MRI
Ante Zhu1,2, Diego Hernando2,3, Kevin M. Johnson2,3, and Scott B. Reeder1,2,3,4,5

1Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, United States, 2Radiology, University of Wisconsin-Madison, Madison, WI, United States, 3Medical Physics, University of Wisconsin-Madison, Madison, WI, United States, 4Medicine, University of Wisconsin-Madison, Madison, WI, United States, 5Emergency Medicine, University of Wisconsin-Madison, Madison, WI, United States

Recent studies have suggested the presence of a short-T2* signal component in the liver. The origin and MR properties of this signal have not been determined but have been shown to confound the liver fat quantification when using short echo times. In this work, we developed a UTE chemical shift-encoded MRI technique and a multi-component reconstruction to characterize short-T2* liver signals. A short-T2* signal fraction of 11.6±2.4% with an R2* of 2222±281s-1 was measured in seven healthy volunteers. This study demonstrated the presence of the short-T2* signal component in healthy livers and provided an initial estimate to guide future studies.

121
Plasma 10
REnal Flow and Microstructure AnisotroPy (REFMAP) MRI in Normal and Peritumoral Renal Tissue
Andrea Liu1, Artem Mikheev2, Henry Rusinek2,3, William Huang4, Hersh Chandarana2,3, and Eric Edward Sigmund2,3

1NYU School of Medicine, NYU Langone Medical Center, New York, NY, United States, 2Radiology, NYU Langone Medical Center, New York, NY, United States, 3Center for Advanced Imaging and Innovation (CAIIR), New York, NY, United States, 4Urology, NYU Langone Medical Center, New York, NY, United States

Using a recently developed joint intravoxel incoherent motion (IVIM)- diffusion tensor imaging (DTI) protocol for kidney evaluation, we present reproducibility analysis of its metrics in normal volunteers, as well as pilot assessments in several patients with renal masses prior to surgery.  Reproducibility analysis indicates a subset of robust parameters, including structural and microcirculation markers in both cortex and medulla, for clinical application.  Preliminary results in renal mass patients suggest multifactorial differences from controls, supporting the need for advanced diffusion characterization in assessing renal functional reserve.

122
Plasma 11
Addressing Metabolic Heterogeneity in Clear Cell Renal Cell Carcinoma with Quantitative Magnetic Resonance Imaging
Yue Zhang1, Durga Udayakumar1, Ling Cai2, Zeping Hu2, Payal Kapur3, Eun-Young Kho2, Andrea Pavía-Jiménez4, Michael Fulkerson1, Alberto DiazdeLeon1, Qing Yuan1, Ivan E Dimitrov5, Takeshi Yokoo1, Jin Ye6, Matthew Mitsche6, Hyeonwoo Kim6, Jeffrey McDonald6, Yin Xi1, Ananth J Madhuranthakam1, Robert E Lenkinski1, Jeffrey A Cadeddu7, Vitaly Margulis7, James Brugarolas8, Ralph J Deberardinis2, and Ivan Pedrosa1

1Radiology, UT Southwestern Medical Center, Dallas, TX, United States, 2Children's Medical Center Research Institute, UT Southwestern Medical Center, Dallas, TX, United States, 3Pathology, UT Southwestern Medical Center, Dallas, TX, United States, 4Internal Medicine, UT Southwestern Medical Center, Dallas, TX, United States, 5Philips Medical Systems, Cleveland, OH, United States, 6Molecular Genetics, UT Southwestern Medical Center, Dallas, TX, United States, 7Urology, UT Southwestern Medical Center, Dallas, TX, United States, 8Internal Medicine & Kidney Cancer Program, UT Southwestern Medical Center, Dallas, TX, United States

MRI fat fraction (FF, Dixon) and % enhancement (DCE) measurements in vivo in clear cell renal cell carcinoma (ccRCC) were correlated with intracellular fat (Oil Red O), lipidomic profile (mass spectrometry), and cellular metabolomics of tissue samples isolated from anatomically co-registered locations in the same tumor. In vivo FF correlated positively with histologic fat content, spectrometric cholesterol and triglycerides; and negatively with spectrometric free fatty acids and phospholipids. ISUP grade 2 and 3 tumors exhibited marked intra-tumoral heterogeneity in FF whereas grade 4 tumors had reduced lipid accumulation. MRI-derived FF and % enhancement correlated with altered metabolic features of ccRCC.

123
Plasma 12
Liver Fat Reduction Following Bariatric Weight Loss Surgery is Greater in the Right Lobe of the Liver
Soudabeh Fazeli Dehkordy1, Tanya Wolfson2, Cheng William Hong1, Alexandra Schlein1, Yesenia Covarrubias1, Jennifer Cui1, Ethan Z Sy1, Adrija Mamidipalli1, Gavin Hamilton1, Scott B Reeder3, and Claude B Sirlin1

1Liver Imaging Group, Department of Radiology, University of California San Diego, San Diego, CA, United States, 2Computational and Applied Statistics Laboratory, University of California San Diego, San Diego, CA, United States, 3Department of Radiology, Medical Physics, Biomedical Engineering, Medicine, and Emergency Medicine, University of Wisconsin Madison, Madison, WI, United States

As liver fat is heterogeneously distributed, longitudinal changes in liver fat may vary between liver segments. We used confounder-corrected chemical-shift-encoded MRI to examine longitudinal changes in proton density fat fraction (PDFF) of individual liver segments in obese adults following a weight-loss program comprising a very low calorie diet (VLCD) followed by bariatric weight loss surgery (WLS). We observed that changes in PDFF in the 5-month postoperative period vary across segments, with right-lobe segments having more rapid reduction in liver fat.

124
Plasma 13
In Vivo Biochemical and Histological Validation of Proton Density Fat Fraction as a Quantitative Biomarker of Hepatic Steatosis
Scott B Reeder1,2,3,4,5, Curtis N Wiens1, Nathan Artz1,6, Jeffrey B Schwimmer7, Rashmi Agni8, Rao Watson8, Tanya Wolfson9, Anthony Gamst10, Guilherme Campos11,12, Santiago Horgan13, Luke Funk12, Garth Jacobsen13, Jacob Greenberg12, Alexandra Schlein14, Yesenia Covarrubias14, Jonathan C Hooker14, Michael S Middleton14, Gavin Hamilton14, Benjamin Ratliff1,3, Alan B McMillan1, Diego Hernando1,2, and Claude B Sirlin14

1Radiology, University of Wisconsin, Madison, WI, United States, 2Medical Physics, University of Wisconsin, Madison, WI, 3Biomedical Engineering, University of Wisconsin, Madison, WI, United States, 4Medicine, University of Wisconsin, Madison, WI, United States, 5Emergency Medicine, University of Wisconsin, Madison, WI, United States, 6Diagnostic Imaging, St. Jude Children’s Research Hospital, 7Pediatrics, University of California, San Diego, 8Pathology, University of Wisconsin, 9San Diego Super Computer Center, University of California, San Diego, 10Mathematics, University of California, San Diego, 11Surgery, Virginia Commonwealth University, Richmond, VA, United States, 12Surgery, University of Wisconsin, Madison, WI, 13Surgery, University of California, San Diego, San Diego, CA, United States, 14Radiology, University of California, San Diego

The purpose of this study was to validate complex- and magnitude-based quantitative chemical-shift encoded MRI (CSE-MRI) to quantify PDFF as an accurate biomarker of hepatic steatosis. A biopsy-MRI correlation study was performed in 95 obese subjects undergoing bariatric weight loss surgery. The results of biochemical triglyceride, conventional histological, digital histological, and MR spectroscopy analyses were used as reference standards. Strong correlations were found between MRI-PDFF measured using both complex- and magnitude-based CSE-MRI methods vs. each reference standard. This is the first cross-sectional in-vivo study validating PDFF as a biomarker of hepatic steatosis using biochemical triglyceride concentration as the reference. 

125
Plasma 14
Hepatic MRI-PDFF is positively correlated with R2* across a range of fat spectral models
Cheng William Hong1, Adrija Mamidipalli1, Jonathan C Hooker1, Gavin Hamilton1, Tanya Wolfson2, Soudabeh Fazeli Dehkordy1, Michael S Middleton1, Scott B Reeder3, Rohit Loomba4, and Claude B Sirlin1

1Liver Imaging Group, Department of Radiology, University of California, San Diego, San Diego, CA, United States, 2Computational and Applied Statistics Laboratory, University of California, San Diego, San Diego, CA, United States, 3Departments of Radiology, Medical Physics, Biomedical Engineering, Medicine, and Emergency Medicine, University of Wisconsin, Madison, Madison, WI, United States, 4NAFLD Research Center, Division of Gastroenterology, Department of Medicine, University of California, San Diego, San Diego, CA, United States

Confounder-corrected estimation of proton-density fat fraction (PDFF) concurrently estimates R2* (1/T2*), a parameter modeled to account for R2* signal decay. Although they are derived from the same mathematical model, PDFF and R2* are generally considered independent parameters. Emerging evidence, however, suggests that PDFF and R2* are positively correlated. This study confirms that PDFF and R2* are positively correlated, and this association is not a spurious result of the applied fat multipeak spectral model.

126
Plasma 15
Anatomical and functional deficits of the placenta identified by MRI in a rat model of preeclampsia
Emily Alexandria Waters1, Pamela Monahan2, Chad R Haney1, Michael Kevin Fritsch3, Thomas J Meade4, and Kelly E Mayo2

1Center for Advanced Molecular Imaging, Northwestern University, Evanston, IL, United States, 2Molecular Biosciences, Northwestern University, Evanston, IL, United States, 3Pathology, Northwestern University Feinberg School of Medicine, Chicago, IL, United States, 4Chemistry, Molecular Biosciences, and Neurobiology, Northwestern University, Evanston, IL, United States

Though a large percentage of poor pregnancy outcomes such as stillbirth and preterm birth are related to placental dysfunction, the gold-standard of diagnosing placental pathology remains  examination of the placenta by a pathologist after delivery.  We demonstrate that anatomical and functional MRI can detect features of placental pathology correlating with ex vivo measures in a rat model of pre-eclampsia.


Electronic Power Pitch Poster

Poster: Highlights of Multiparametric Acquisition & Reconstruction

Exhibition Hall Monday 14:45 - 15:45

127
Plasma 16
Relaxation in Polar Coordinates: Analysis and Optimization of MR-Fingerprinting
Jakob Assländer1,2, Daniel K Sodickson1,2, Riccardo Lattanzi1,2, and Martijn A Cloos1,2

1Dept. of Radiology - Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, New York, NY, United States, 2Dept. of Radiology - Center for Advanced Imaging Innovation and Research, New York University School of Medicine, New York, NY, United States

This work analyses relaxation in balanced non-steady-state free precession sequences. Transforming the Bloch equation to polar coordinates gives insights in the spin dynamics and provides the basis for robust numerical optimization of the excitation pattern. The employed optimal control algorithm results in spin trajectories that allow for parameter mapping with considerably reduced noise, as shown in in vivo MR-fingerprinting experiments. The simple shapes of the optimized spin trajectories provide a basis for further analysis of the encoding process of relaxation times for parameter mapping.

128
Plasma 17
Quantification of Flow by Magnetic Resonance Fingerprinting
Sebastian Flassbeck1, Simon Schmidt1, Mathies Breithaupt1,2, Peter Bachert1, Mark E. Ladd1, and Sebastian Schmitter1,3

1Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany, 2Institute for Forensic Medicine and Traffic Medicine, Germany, 3Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany

The goal of this work is to investigate and demonstrate 'flow MRF', a technique that quantifies T1 and T2 within static tissue regions around a vessel (e.g. vessel wall) with high spatial resolution while simultaneously quantifying the 3D blood velocity vector within the vessel with high precision and high spatiotemporal resolution. The results show that simultaneous mapping of pulsatile flow and T1/T2 quantification of static tissue is feasible with MRF. The quantification of flow as an additional parameter will further increase the efficiency of MRF and may provide new diagnostic value in cardiovascular diseases.

129
Plasma 18
Applications of Low Rank Modeling to Fast 3D Magnetic Resonance Fingerprinting (MRF)
Dan Ma1, Eric Y. Pierre2, Debra McGivney1, Bhairav Mehta1, Yong Chen1, Yun Jiang1, and Mark Griswold1

1Radiology, Case Western Reserve University, Cleveland, OH, United States, 2The Florey Institute of Neuroscience and Mental Health, Melbourne, Australia

The goal of this study is to accelerate the acquisition time of 3D magnetic resonance fingerprinting (MRF) using a low-rank model-based method kt-SVD-MRF. With a total factor of 144 acceleration rate, 3D T1, T2 and proton density (M0) maps can be acquired from a whole brain scan with a resolution of 1.17x1.17x3 mm3 in 2.7 minutes.

130
Plasma 19
Magnetic Resonance Fingerprint Compression with Multiple Channel Transmission
Riccardo Lattanzi1,2, Bei Zhang1, Florian Knoll1, Jakob Assländer1, and Martijn Cloos1

1Radiology, Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, New York, NY, United States, 2Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, NY, United States

Singular value decomposition (SVD) and view-sharing compression can decrease the size of the dictionary without compromising accuracy in magnetic resonance fingerprinting (MRF). While the latter accounts for the B1+ of multiple transmit channels in the dictionary, the SVD compression scheme was designed for single-channel transmission. In this work we extended SVD-based fingerprint compression to the case of two or more independent RF sources and evaluated its performance in simulation. We showed that accurate parametric maps can be achieved using only six SVD components, both in fully-sampled and highly under-sampled MRF experiments. Future work will include optimization of k-space under-sampling.

131
Plasma 20
Intra-Voxel Spatial Resolution Using Magnetic Resonance Fingerprinting
Thomas Amthor1, Karsten Sommer1, Peter Koken1, Jakob Meineke1, and Mariya Doneva1

1Philips Research, Hamburg, Germany

We demonstrate the use of Magnetic Resonance Fingerprinting to retrospectively increase spatial resolution in slice-encoding direction, making use of the non-uniform nature of the excitation slice profile.  Assigning individual fingerprints to substances present at different spatial positions within the excited voxel, a multi-compartment analysis recovers the spatial distribution of the components.


132
Plasma 21
Dictionary approach to partial volume estimation with MR Fingerprinting: Validation and application to brain tumor segmentation
Anagha Deshmane1, Debra McGivney2, Chaitra Badve3, Vikas Gulani2,3, and Mark Griswold2

1Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States, 2Radiology, Case Western Reserve University, Cleveland, OH, United States, 3Radiology, University Hospitals, Cleveland, OH, United States

MR Fingerprinting signal evolutions can be used to estimate partial volumes of tissues in addition to tissue relaxation times. Two approaches to tissue fraction estimation, a pseudoinverse calculation and dictionary-based or constrained solution, are quantitatively compared in the presence of four potential error sources.  The constrained approach is found to more accurately estimate tissue fractions, and also to improve segmentation of pathology.

133
Plasma 22
Mitigation of Spiral Undersampling Artifacts in Magnetic Resonance Fingerprinting (MRF) by Adapted Interleave Reordering
Josef Pfeuffer1, Argyrios Kechagias1, Craig H. Meyer2, Gregor Körzdörfer1, and Mathias Nittka1

1Application Development, Siemens Healthcare, Erlangen, Germany, 2Biomedical Engineering, University of Virginia, Charlottesville, VA, United States

In MRF fast spiral scanning is done with variable FA/TR using a highly – up to 48-fold – undersampled trajectory. Spatial undersampling artifacts are mitigated by the MRF dictionary-matching process for the resulting quantitative T1/T2 maps. In this study, we demonstrate how undersampling artifacts can bias MRF results and present strategies to minimize them by spiral-interleave reordering adapted to the specific MRF encoding scheme. An experimental procedure is developed to test for a potential spatial bias in a specific spiral and MRF encoding scheme. The sources of spatial variances are mitigated with appropriate distribution of undersampling artifacts over the temporal MRF encoding.

134
Plasma 23
Fat Signal Fraction Determination Using MR Fingerprinting
Jason Ostenson1,2 and E. Brian Welch1,3,4

1Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN, United States, 2Program in Chemical and Physical Biology, Vanderbilt University, Nashville, TN, United States, 3Department of Radiology and Radiological Sciences, Vanderbilt University, 4Department of Biomedical Engineering, Vanderbilt University

Magnetic resonance fingerprinting employing multiple echo times is used to quantify fat signal fraction both in phantoms and in vivo on a human 3 Tesla scanner. Reasonable agreement is seen in fat signal fraction maps and intra-class correlation between standard and MRF methods.

135
Plasma 24
Accelerated Magnetic Resonance Fingerprinting using Soft-weighted key-Hole (MRF-SOHO)
Gastao Cruz1, Andreia S. Gaspar1, Tom Bruijnen2, René Botnar1, and Claudia Prieto1

1Division of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom, 2Center for image sciences, University Medical Center Utrecht, Utrecht, Netherlands

Magnetic Resonance Fingerprinting estimates multi-parametric maps from a series of highly undersampled time-point images. However, MRF scan times are still long due to the large amount of time-point images (~1000) required to produce accurate multi-parametric maps. Here we propose to exploit redundant information in time-point images with similar contrast to accelerate the MRF scan by further undersampling each time-point image and/or significantly reducing the number of required images in the series. The proposed approach achieved an acceleration factor of 5.7× compared to conventional undersampled MRF while maintaining parametric map quality.

136
Plasma 25
Magnetic Resonance Fingerprinting - Evaluation of Brain Gliomas in Comparison to a Conventional Advanced Tumor Protocol - Preliminary Study
Siegfried Trattnig1,2, Wolfgang Bogner1, Bernhard Strasser1, Peter Bär1, Simone Kitzer1, Pavol Szomolanyi1, Matthias Nittka3, Wolfgang Marik4, Martin Zalaudek1, Markus Schreiner1, and Elisabeth Springer1

1Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, High Field MR Center, Vienna, Austria, 2Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria, 3Siemens Healthineers, Erlangen, Germany, 4Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria

Synopsis: MR Fingerprinting (MRF) was compared to an advanced brain tumor protocol in 10 patients with surgically proven gliomas. The T1 and T2 relaxation times provided by MRF in one scan showed a high correlation with conventionally measured T1 and T2 values. MRF obtained T1 and T2 values allowed a statistically significant differentiation between low and high grade gliomas. MRF with quantitative data and the possibility to generate synthetic MR contrast images may replace conventional MR sequences in the future.  

137
Plasma 26
Joint estimation of arterial input function and tracer kinetic parameters from under-sampled DCE-MRI
Yi Guo1, Sajan Goud Lingala1, R Marc Lebel2, and Krishna S Nayak1

1Electrical Engineering, University of Southern California, Los Angeles, CA, United States, 2GE Healthcare, Calgary, AB, Canada

Direct reconstruction of tracer kinetic (TK) parameter maps from under-sampled DCE-MRI has recently been demonstrated. However, this method assumes the arterial input function (AIF) is known or pre-determined. Any mismatches between the assumed AIF and the underlying patient-specific AIF can cause large inaccuracies in the final TK parameters. We propose a novel approach to extract patient-specific AIFs from under-sampled data, while jointly estimating the TK parameter maps. Reconstruction is performed by cycling through the  problems of AIF extraction, TK parameter estimation and, data consistency. We demonstrate this approach on brain tumor DCE data sets, where high fidelity AIFs are extracted up to an under-sampling rate of 100x.

138
Plasma 27
Highly accelerated DCE imaging with integrated T1 mapping
R Marc Lebel1,2,3, Yi Guo4, Sajan Goud Lingala4, RIchard Frayne2,3, and Krishna S Nayak4

1GE Healthcare, Calgary, AB, Canada, 2Radiology, University of Calgary, Calgary, AB, Canada, 3Seaman Family Centre, Calgary, AB, Canada, 4Electrical Engineering, University of Southern California, Los Angeles, CA, United States

Dynamic contrast enhanced (DCE) MRI requires accurate and precise baseline T1 and M0 maps for pharmacokinetic modeling. Advances in dynamic acquisitions and reconstructions have enabled high resolution DCE imaging with full anatomical coverage. Rapidly obtaining high SNR T1/M0 maps with the same spatial resolution has become a limiting factor for advanced DCE methods. We present a single highly accelerated acquisition that first performs the T1/M0 mapping then dynamic imaging. A model-based reconstruction is used to estimate the T1/M0 maps. This method makes effective use of scan time and generates maps that are superior to separately acquired ones.

139
Plasma 28
Calibrationless Parallel Imaging in Multi Echo/Contrast Data
Berkin Bilgic1, Bo Zhao1, Itthi Chatnuntawech2, Lawrence L Wald1, and Kawin Setsompop1

1Martinos Center for Biomedical Imaging, Charlestown, MA, United States, 2National Nanotechnology Center, Pathum Thani, Thailand

Parallel imaging relies on fully-sampled calibration data to estimate k-space kernels or sensitivities used to reconstruct subsampled acquisitions. Emerging techniques use low-rank modeling, or joint estimation of sensitivities and image content via nonlinear optimization, to reduce the dependency on calibration data. In a typical study, images at multiple echoes/contrasts are acquired using the same coil sensitivities. Here, we exploit this joint information to dramatically improve conditioning of calibrationless nonlinear inversion and employ joint sparsity to improve reconstruction. To achieve better performance, we also propose complementary k-space undersampling between images to form a composite image with reduced aliasing to initialize the optimization.

140
Plasma 29
Accelerated Cardiac Diffusion Tensor Imaging Using a Joint Low-Rank and Sparsity Constraint
Sen Ma1,2, Christopher Nguyen1, Anthony Christodoulou1,3, Daniel Luthringer4, Jon Kobashigawa3, and Debiao Li1,2

1Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States, 2Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, United States, 3Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States, 4Department of Pathology, Cedars-Sinai Medical Center, Los Angeles, CA, United States

We present an image reconstruction technique to accelerate cardiac diffusion tensor imaging by jointly applying a low-rank and spatial sparsity constraint. We evaluated four acquisition schemes at different undersampling levels on 9 ex vivo diseased human heart, evaluating the reconstruction quality based on the resulting helix angle (HA) maps and helix angle transmurality (HAT) values. A Wilcoxon signed rank test was performed to statistically evaluate changes in HAT to determine the highest achievable acceleration factor for each acquisition scheme. Our framework shows promise in greatly reducing scan time while preserving the fiber architecture features of heart failure. 

141
Plasma 30
An open-source hardware and software system for video-gated MRI
Nicolai Spicher1, Stephan Orzada2, Stefan Maderwald2, Markus Kukuk1, and Mark E Ladd2,3

1University of Applied Sciences and Arts Dortmund, Dortmund, Germany, 2Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany, 3Division of Medical Physics in Radiology, German Cancer Research Center, Heidelberg, Germany

The limitations of contact-based hardware (e.g. electrocardiography, pulse oximetry) for cardiac activity measurement pose an obstacle in many ultra-high-field MRI examinations. In this work, we present a freely available hardware and software system for acquisition and processing of video signals from human skin that we developed with the aim to make this contact-free method available to other researchers.


Electronic Power Pitch Poster

Poster: Cutting Edge fMRI

Exhibition Hall Monday 17:15 - 18:15

237
Plasma 1
Cortical depth-dependent fMRI: heterogeneity across tasks, across participants, across days and along the cortical ribbon
Laurentius Huber 1, Daniel A Handwerker1, Andrew Hall1, David C Jangraw2, Javier Gonzalez-Castillo1, Maria Guidi3, Dimo Ivanov4, Benedikt A Poser4, and Peter A Bandettini1

1SFIM, NIMH, Bethesda, MD, United States, 2NIMH, United States, 3Max Planck Institute for human cognitive and Brain science, Leipzig, Germany, 4MBIC, Maastricht University, Netherlands

Measurements of depth-dependent cortical activity provide insights on directional activity between brain areas. While previous studies demonstrated the feasibility of human depth-dependent fMRI, the stability and reliability of depth-dependent results are less studied. In this work, we investigate sources of inconsistencies in depth-dependent activity profiles. We find that depth-dependent activity profiles are highly reproducible across different scanning sessions. They are, however, quite variable within cortical areas across different cross sections along the cortical ribbon. Only when depth-dependent profiles are considered with respect to their location along the cortical ribbon, task-driven modulations of input-output activity become consistent across participants.

238
Plasma 2
Simultaneous GCaMP6 based fiber photometry and fMRI in rats
Zhifeng Liang1,2, Yuncong Ma2, and Nanyin Zhang2

1Institute of Neuroscience, Chinese Academy of Sciences, Shanghai, People's Republic of China, 2Department of Biomedical Engineering, Pennsylvania State University, PA, United States

Measuring neural activities simultaneously with fMRI using electrophysiology approaches has been valuable in elucidating neural basis of BOLD signals, but is also technically challenging due to interferences from MRI scanners. Optical recording of neural activities such as calcium signals has minimal interferences from MRI, and thus has opened new avenues of simultaneous acquisition of neural and BOLD signals. The current study first demonstrated the feasibility of using protein based calcium indicator (GCaMP6) to simultaneously and repeatedly acquire calcium and BOLD signals in the MRI scanner, with significant increases of both signals in response to visual stimulation.    

239
Plasma 3
Optogenetic resting-state fMRI reveals thalamic modulation of long-range sensory networks
Alex T. L. Leong1,2, Xunda Wang1,2, Russell W. Chan1,2, Leon C. Ho1,2, Yongrong Qiu1,2, Celia M. Dong1,2, and Ed X. Wu1,2

1Laboratory of Biomedical Imaging and Signal Processing, The University of Hong Kong, Hong Kong, Hong Kong, 2Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong, Hong Kong

One grand challenge in contemporary neuroscience is to achieve an integrated understanding of large-scale brain-wide networks. Resting-state functional MRI (rsfMRI) has helped reveal such brain-wide networks, yet, the neural bases underlying them remain unclear. Utilizing optogenetic excitation and pharmacological inactivation to manipulate the neural activity of somatosensory thalamocortical neurons, the present study demonstrated that rsfMRI connectivity is enhanced and decreased respectively. Furthermore, our findings suggest that optogenetically-evoked propagating low frequency activity (~1Hz) within the thalamo-cortico-thalamic network facilitate the enhancement of rsfMRI connectivity. Our work offers an exciting avenue to dissect the underlying neural bases of brain-wide functional connectivity.

240
Plasma 4
Global signal regression alters the correlation between resting-state BOLD fluctuations and EEG vigilance measures
Maryam Falahpour1, Alican Nalci1, Chi Wah Wong1, and Thomas Liu1

1Center for functional MRI, University of California San Diego, San Diego, CA, United States

Global signal regression (GSR) is a commonly used preprocessing approach in the analysis of resting state fMRI data. Utilizing simultaneously acquired EEG/fMRI data in humans, we found that GSR alters the correlation between the resting-state BOLD fluctuations and EEG vigilance. We show that GSR reveals BOLD-EEG correlations that are otherwise obscured and use a time segmentation approach to argue that the observed effects are not simply an artifact of GSR.  

241
Plasma 5
What is the neurophysiological bases of resting state functional connectivity?
Hanbing Lu1, Saul Jaime2, Elliot A Stein1, Jose E Cavazos2, and Yihong Yang1

1National Institute on Drug Abuse, NIH, Baltimore, MD, United States, 2University of Texas Health Science Center at San Antonio, TX, United States

Despite wide application of resting state functional connectivity (rsFC) in systems neuroscience, fundamental aspects of rsFC remain poorly understood. Concurrent multi-channel electrophysiological recording and fMRI were performed in rat striatum along with pharmacological manipulation of VTA dopamine neuronal activity. Results suggest that LFPs of different frequency bands contribute distinctively and differentially to the observed BOLD fluctuations, and that cross-frequency phase-amplitude coupling (PAC) is the organizing mechanism through which low frequency LFPs orchestrate neural activity that underlies the BOLD rsFC. Our data imply that where there is a synchronized low frequency LFP signal, there is also resting state BOLD functional connectivity. rsFC does not necessarily reflect structural connectivity.

242
Plasma 6
Functional Neuroimaging in the Brain using Magnetic Resonance Elastography
Samuel Patz1,2, Navid Nazari3, Paul E. Barbone4, Ben Fabry5, Dan Fovargue6, David Nordsletten6, and Ralph Sinkus6

1Radiology, Brigham & Women's Hospital, Boston, MA, United States, 2Harvard Medical School, Boston, MA, United States, 3Biomedical Engineering, Boston University, Boston, MA, United States, 4Mechanical Engineering, Boston University, Boston, MA, United States, 5Physics, University of Erlangen-Nuremberg, Erlangen, Germany, 6Biomedical Engineering, Kings College London, London, United Kingdom

Using electrical stimulation of the hind limb, Magnetic Resonance Elastography (MRE) was used to observe localized changes in the complex shear modulus G=G’ + iG’’ of the mouse brain cortex. “Stimulation” and “no stimulation” paradigms were alternated every 10s to avoid habituation.  An average increase of ~14% in G’ was observed whereas no significant change was seen for G’’. The effect was observed in six of seven mice studied. The mechanism responsible for this effect is hypothesized to be due to calcium influx into the neuronal cells. 

243
Plasma 7
Fully Automated Learning based Method for resting state fMRI Connectomics Analysis
Arathi Sreekumari1, Radhika Madhavan1, Rakesh Mullick1, Teena Shetty2, Pratik Mukherjee3, Joseph Masdeu4, Luca Marinelli5, and Suresh Emmanuel Joel1

1GE Global Research, Bangalore, India, 2Hospital for Special Surgery, New York, NY, United States, 3University of California, San Francisco, San Francisco, CA, United States, 4Houston Methodist, Houston, TX, Houston, TX, United States, 5GE Global Research, Niskayuna, NY, United States

Machine learning approaches are increasingly being used to identify discriminative features derived from functional connectome data that best separate a diseased group from healthy cohorts. Here, we propose a novel framework for longitudinal prediction of disease outcome, using a combination of unsupervised and supervised learning approaches. Using this framework, we achieve 81% accuracy for prediction of mild traumatic brain injury outcome at 3-months by learning features from functional connectomes at the acute stage of injury (<1 week).

244
Plasma 8
A Multiband Multi-Echo Simultaneous ASL/BOLD Acquisition for Resting State Functional Connectivity
Alexander D. Cohen1, Andrew S. Nencka1, and Yang Wang1

1Radiology, Medical College of Wisconsin, Milwaukee, WI, United States

A multiband multi-echo simultaneous ASL/BOLD sequence was developed and utilized to evaluate resting state connectivity. ASL sequences have inherently long TRs due to the tagging and delay components. To compensate for this, four echoes were collected allowing multi-echo independent component analysis (ME-ICA) to be employed to denoise the BOLD data. A seed-based analysis was used for the computation of functional connectivity. Temporal signal to noise ratio (tSNR) was significantly higher for the denoised data resulting in an increase in connectivity strength, cluster size, and number of clusters. The sequence also allowed perfusion-weighted connectivity to be computed. 

245
Plasma 9
The first two years of whole brain functional development can be separated into three distinct time periods
Weiyan Yin1 and Weili Lin2

1Department of Biomedical Engineering and Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, NC, United States, 2Department of Radiology and Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, NC, United States

Resting functional connectivity has been utilized to characterize early brain functional development. Most of the studies to date have grouped subjects based on biological age, enabling assessment of brain functional maturation. However, this grouping approach assumes that subjects at the same age exhibit similar functional maturation, which may not be valid considering the paces of functional maturation could substantially vary among individuals. In this study, the normalized-Cut method was used to cluster connectivity matrixs of 71 normally developing children, 0 to 2 years of age, into distinct age periods (functional age) reflecting stable brain funcitonal connectivity. We found that brain functional development during the first two years of life consists of three distinct time periods 0 – 2, 3 – 6, and 7 - 26 months, respectively. In addition, 17 core brain regions were identified, which largely drove our clustering results. These regions could be of critical importance for early brain development.

246
Plasma 10
MRI Connectivity Predictors of Post-Surgical Seizure Outcome in Temporal Lobe Epilepsy
Victoria L Morgan1, Dario J Englot2, Adam W Anderson3, Bennett A Landman4, Ahmet Cakir4, Baxter P Rogers1, and Bassel Abou-Khalil5

1Institute of Imaging Science, Vanderbilt University, Nashville, TN, United States, 2Neurosurgery, Vanderbilt University, Nashville, TN, United States, 3Biomedical Engineering, Vanderbilt University, Nashville, TN, United States, 4Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN, United States, 5Neurology, Vanderbilt University, Nashville, TN, United States

Surgical resection of the mesial temporal lobe is a common treatment of drug-resistant temporal lobe epilepsy (TLE). The ability to more accurately predict post-surgical seizure outcome in these patients is a significant clinical challenge.  Towards this end, MRI functional and structural connectivity were used to identify a common pattern across a seizure propagation network in TLE patients with seizure free outcome. Then, in test patients with good and bad outcomes, similarity with the model pattern was significantly associated with seizure outcome. Therefore, this non-invasive method may predict seizure outcomes in TLE, which was not possible from the clinical assessments alone. 

247
Plasma 11
CEST fMRI at ultra-high magnetic field
Tangi Roussel1, Lucio Frydman2, Denis Le Bihan1, and Luisa Ciobanu1

1NeuroSpin, Commisariat à l'Energie Atomique et aux Energies Alternatives, Gif-sur-Yvette, France, 2Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel

BOLD indirectly measures brain activity based on neurovascular coupling, a reporter which is naturally poor in both its spatial and temporal resolutions. Emerging methods involving spectroscopy (fMRS) and diffusion fMRI suggest that metabolic and structural modifications are taking place in the activated cells. In this paper, we introduce Chemical Exchange Saturation Transfer (CEST)-weighted fMRI as a new method to explore changes in rat brain activation at 17.2T. Monte Carlo simulations were performed to optimize the acquisition and processing methods. Experimentally, CEST-weighted fMRI activation maps showed negative contrast at +1.2ppm most likely originating from changes in the glucose metabolism.

248
Plasma 12
EPI-signal fluctuations at the cardiac frequency: A tissue-specific quantification of inflow, displacement and potential oxygenation effects over the cardiac cycle.
Olivia Viessmann1 and Peter Jezzard1

1FMRIB Centre, Nuffield Department of Clinical Neurosciences, Oxford University, Oxford, United Kingdom

The impact and transmission mechanisms of the cardiac arterial pressure wave into brain tissue are not fully understood. It is hypothesised that age-related arterial stiffening and increased CBF pulsatility leads to propagation of the arterial wave further down the vascular tree causing tissue damage. Here we quantify inflow ($$$S_0$$$) and displacement/oxygenation ($$$T_2^*$$$) induced fluctuations of the EPI-signal at the cardiac frequency. We relate the EPI-signal phase at the cardiac frequency to the fluctuations of $$$S_0$$$ and $$$T_2^*$$$ over the cardiac cycle in the arteries, veins and tissue. 

249
Plasma 13
The global resting-state fMRI signal is associated with opposite changes at subcortical structures regulating arousal.
Xiao Liu1,2, Jacco A de Zwart2, David A Leopold3, and Jeff H Duyn2

1Biomedical Engineering, Pennsylvania State University, University Park, PA, United States, 2National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, MD, United States, 3National Institute of Mental Health, National Institues of Health, MD, United States

Spontaneous, large scale fluctuations (LSF) in neocortical fMRI activity may result from arousal variations. To investigate the role of arousal, we examined an fMRI database for local fMRI changes at subcortical arousal-regulating structures associated with widespread fMRI co-activations in the neocortex. We identified three subcortical regions that showed anti-polar signal changes with LSF. These regions, known for promoting wakefulness, included the Nucleus Basalis, the Dorsal Midline Thalamus, and the Substantia Nigra. This finding is further evidence of a putative role of arousal in LSF, and suggest that caution should be exercised when extracting functional connectivity measures from fMRI data. 

250
Plasma 14
Functional connectivity is globally altered by schizophrenia-linked genes
Garth J Thompson1,2, Karen Perez De Arce3, Basavaraju G Sanganahalli1,2,4, Stephen M Strittmatter5, Thomas Biederer3, and Fahmeed Hyder1,2,4,6

1Radiology and Biomedical Imaging, Yale University, New Haven, CT, United States, 2Magnetic Resonance Research Center (MRRC), Yale University, New Haven, CT, United States, 3Neuroscience, Tufts University School of Medicine, Boston, MA, United States, 4Quantitative Neuroscience with Magnetic Resonance (QNMR) Core Center, Yale University, New Haven, CT, United States, 5Cellular Neuroscience, Neurodegeneration, and Repair Program, and Departments of Neurology and Neurobiology, Yale University School of Medicine, New Haven, CT, United States, 6Biomedical Engineering, Yale University, New Haven, CT, United States

Resting state fMRI shows increased global synchrony in schizophrenia at rest, but mechanisms remain speculative. We tested mice with knockout of SynCAM1 (related to synaptic organization), LRRTM1 (related to schizophrenia symptoms) and both genes using whisker-stimulation and resting-state fMRI. SynCAM1 was linked to stronger whisker barrel activation and to greater functional connectivity. However, this was lost if global signal regression was performed. Global signal amplitude was significantly higher in SynCAM1 knockout mice, and amplified by the additional knockout of LRRTM1. We hypothesize this is due to disrupted synaptic connections by SynCAM1 knockout, which are partially protected when LRRTM1 is present.

251
Plasma 15
Population Receptive Field Mapping of Human Somatosensory Cortex at 7 T
Michael Asghar1, Rosa Sanchez-Panchuelo1, Denis Schluppeck2, and Susan Francis1

1SPMIC, School of Physics, University of Nottingham, Nottingham, United Kingdom, 2School of Psychology, University of Nottingham, Nottingham, United Kingdom

To advance the investigation of function and structure in human somatosensory areas, detailed topographic maps that are reproducible across time are invaluable. In previous 7 Tesla fMRI studies using travelling wave (TW) and event-related (ER) paradigms, the functional parcellation of digit representations in human S1 has been shown. Here, we present the application of ‘population Receptive Field’ analysis (pRF) to high-resolution fMRI data from somatosensory cortex. The pRF method can provide information beyond preferred stimulus location, such as measures of receptive field size. We also show how surface coils can be used to improve spatial resolution in somatotopic maps.


Electronic Power Pitch Poster

Poster: Quantitation, Prediction & Machine Learning in the Brain

Exhibition Hall Monday 17:15 - 18:15

252
Plasma 16
Machine Learning Based Diagnosis of Early Parkinson's Disease using QSM
Seon Lee1, Joon Yul Choi2, Jeehun Kim2, Sun Won Park3, and Jongho Lee2

1Department of Mechanical and Aerospace Engineering, Seoul National University, Seoul, Korea, Republic of, 2Department of Electrical and Computer Engineering, Seoul National University, Seoul, Korea, Republic of, 3Department of Radiology, Seoul National University Boramae Medical Center, Seoul, Korea, Republic of

This study proposed a support vector machine model to classify early PD patients from healthy controls using QSM. The results validated better performance of SVM than conventional logistic regression based on statistical ordering of backward feature selection. This computer aided technique may help to reduce misdiagnosis rate of early-PD patients.

253
Plasma 17
Reproduciblity of advanced MR metrics in a multi-site, multi-vendor study of mild traumatic brain injury
Andrew Scott Nencka1, Timothy Meier2, Yang Wang1, Yu-Chien Wu3, Brad Swearingen2, Robin Karr1, Melissa Koschnitzke2, Andy Saykin3, Michael McCrea2, and Kevin M Koch1

1Radiology, Medical College of Wisconsin, Milwaukee, WI, United States, 2Neurosurgery, Medical College of Wisconsin, Milwaukee, WI, United States, 3Radiology and Imaging Services, Indiana University, Indianapolis, IN

The Advanced Research Core of the Concussion Assessment Research and Education consortium includes a multi-site, multi-vendor, multi-contrast imaging acquisition protocol with T2 FLAIR, quantitative T2*, task free fMRI, ASL, and DTI. This abstract describes the variance of measurements made in the first year and a half of the study from these imaging methods across a cohort of non-contact sport control athletes. With the variance of these measurements in the colligate athlete population known, the sensitivities of the individual and combined contrasts to diagnose injury and recovery can be assessed.

254
Plasma 18
Characteristic Changes of Volume and Shape of Subcortical Structures in Obsessive-Compulsive Disorder
Lianqing Zhang1, Xinyu Hu1, Ming Zhou1, Lu Lu1, Xiaoxiao Hu1, and Xiaoqi Huang1

1Radiology Department, Huaxi MR Research Center (HMRRC),West China Hospital of Sichuan University, Chengdu, People's Republic of China

We analysis subcortical nucleus volume and shape alterations in a relatively large sample of drug-naive adult patients with Obsessive-Compulsive disorder by using an automatically segmentation and vertex-based shape analysis protocol. Our findings indicated that (i)Gender effects were found in OCD, male patients seems are affected in reward system whereas females might have more disrupted stratum-pallidum-thalamus pathway which might be related to chronic stress. (ii)Shape analysis may provide more anatomical change information from a different perspective. Future structural research should consider shape and volume alterations together when explore brain changes. 

255
Plasma 19
PARTIAL VOLUME ESTIMATION IN MULTIPLE SCLEROSIS LESION SEGMENTATION
Mário João Fartaria 1,2,3, Alexandra Şorega4, Tobias Kober1,2,3, Gunnar Krueger5, Cristina Granziera6,7, Alexis Roche1,2,3, and Meritxell Bach Cuadra2,3,8

1Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland, 2Department of Radiology, Centre Hospitalier Universitaire Vaudois (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland, 3Signal Processing Laboratory (LTS 5), Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland, 4Department of Radiology, Valais Hospital, Sion, Switzerland, 5Siemens Medical Solutions USA, Boston, MA, United States, 6Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Boston, MA, United States, 7Department of Clinical Neurosciences, Centre Hospitalier Universitaire Vaudois (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland, 8Medical Image Analysis Laboratory (MIAL), Centre d'Imagerie BioMédicale (CIBM), Lausanne, Switzerland

Partial volume (PV) is the effect of having a mixture of tissues present within a voxel. This effect occurs in tissue borders and affects small structures such as small multiple sclerosis (MS) lesions. Ignoring PV effects in volumetry may lead to significant estimation errors. Here, we propose a novel automated MS lesion segmentation technique that takes PV effects into account. The proposed method shows higher accuracy in terms of lesion volume estimation compared to a manually segmented ground truth as well as significant improvement in detection of small lesions, also in comparison to two software packages for MS lesion segmentation.  

256
Plasma 20
Predictive cytological topography highlights regions of pathologically confirmed non-enhancing hypercellular tumor in glioblastoma patients
Sarah L Hurrell1, Elizabeth Cochran2, Sean D McGarry1, Amy L Kaczmarowski1, Jennifer Connelly3, Wade Mueller4, Scott D Rand1, Kathleen M Schmainda1, and Peter S LaViolette1

1Radiology, Medical College of Wisconsin, Milwaukee, WI, United States, 2Pathology, Medical College of Wisconsin, Milwaukee, WI, United States, 3Neurology, Medical College of Wisconsin, Milwaukee, WI, United States, 4Neurosurgery, Medical College of Wisconsin, Milwaukee, WI, United States

This study combines clinical brain cancer imaging and pathological microscopy with machine learning to generate predictive maps off pathological features (i.e. new contrasts) based on segmented histological cellularity. Predictive cytological topography (PiCT) maps of cellularity were utilized to detect additional pathologically confirmed infiltrative glioblastoma cellularity beyond margins of contrast enhancement.   

257
Plasma 21
Radiogenomics of 201 WHO grade 2 and 3 gliomas
Manabu Kinoshita1,2, Hideyuki Arita2, Masamishi Takahashi3, Yoshitaka Narita3, Yuzo Terakawa2, Naohiro Tsuyuguchi2, Yoshiko Okita2, Masahiro Nonaka2, Shusuke Moriuchi2, Junya Fukai2, Shuichi Izumoto2, Kenichi Ishibashi2, Yoshinori Kodama2, Kanji Mori2, Koichi Ichimura3, and Yonehiro Kanemura2,4

1Neurosurgery, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka, Japan, 2Kansai Molecular Diagnosis Network for CNS Tumors, Osaka, Japan, 3National Cancer Center Hospital, Japan, 4Osaka National Hospital, Osaka, Japan

Genetic alterations found in WHO grade 2 and 3 gliomas include IDH1/2 and TERT promoter mutations and 1p19q co-deletion. In this research, the authors attempted to test the hypothesis that genetic alterations could contribute to the locations and texture of the tumor by analyzing 201 WHO grade 2 and 3 gliomas using radinogenomic analysis. The authors were able to confirm the hypothesis that genetic alterations do contribute to the locations and textures of the tumor. 15 radionomic features were identified and those features were able to identify 3 genetic subgroups of WHO grade 2 and 3 gliomas.

258
Plasma 22
Classification of Pediatric Brain Tumours using Apparent Diffusion Coefficient – a Multi-Centre Study
Jan Novak1,2, Niloufar Zarinabad1,2, Theodoros N Arvanitis3, Lesley MacPherson4, Daniel Rodriguez 5,6, Richard Grundy6, Dorothee Auer7,8, Tim Jaspan6, Shivaram Avula9, Laurence Abernethy9, Patrick Hales10, Ramneek Kaur10, Darren Hargrave11, Dipayan Mitra12, Simon Bailey13, Nigel Davies14, Christopher Clark10, and Andrew Peet2,15

1Institute of Cancer and Genomic Sciences, University of Birmingham, Birmingham, United Kingdom, 2Oncology, Birmingham Children's Hospital, Birmingham, United Kingdom, 3Institute of Digital Healthcare, University of Warwick, Coventry, United Kingdom, 4Radiology, Birmingham Children's Hospital, Birmingham, United Kingdom, 5Division of Clinical Neuroscience, University of Nottingham, Nottingham, United Kingdom, 6The Children‘s Brain Tumour Research Centre, University of Nottingham, Nottingham, United Kingdom, 7Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham, United Kingdom, 8Department of Neuroradiology, Nottingham University Hospital Trusts, Nottingham, United Kingdom, 9Radiology, Alder Hey Children’s NHF Foundation Trust, Liverpool, United Kingdom, 10Developmental Imaging and Biophysics Section, University College London, London, United Kingdom, 11Haematology and Oncology Department, Great Ormond Street Children's Hospital, London, United Kingdom, 12The Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, United Kingdom, 13Sir James Spence Institute of Child Health, Royal Victoria Infirmary, Newcastle upon Tyne, United Kingdom, 14Radiation Protection Services, University Hospitals Birmingham NHS Foundation Trus, Birmingham, United Kingdom, 15Institute of Cancer and Genomic Sciences, University of Birmingham, BIRMINGHAM, United Kingdom

The purpose of the study was to investigate the potential of apparent diffusion coefficient (ADC) to discriminate between paediatric cerebellar tumours on a multicentre basis using histograms.  A total of 117 paediatric patients with cerebellar tumours (55 Medulloblastomas, 36 Pilocytic Astrocytomas and 26 Ependymomas) were imaged using diffusion weighted imaging across 12 different hospitals using a total of 18 different scanners.  Overall classification accuracies for the ADC histogram metrics were 86 % using Naïve Bayes and 84 % for Random Forest classifier. 

259
Plasma 23
Exploiting radiogenomics data for personalised prediction of glioblastoma
Paul Blakeley1,2, Chia-Feng Lu2,3,4, Fei-Ting Hsu2,5, Li-Chun Hsieh2,5, Yu-Chieh Jill Kao2,3, Huai-Lu Chen1,2, Ping-Huei Tsai2,3,5, Hua-Shan Liu2,6, Gilbert Aaron Lee1,2, and Cheng-Yu Chen2,3,5

1Department of Medical Research, Taipei Medical University Hospital, Taipei, Taiwan, 2Translational Imaging Research Center, College of Medicine, Taipei Medical University, Taipei, Taiwan, 3Department of Radiology, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan, 4Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, Taiwan, 5Department of Medical Imaging, Taipei Medical University Hospital, Taipei, Taiwan, 6School of Biomedical Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei, Taiwan

The present study demonstrates the feasibility of machine learning in radiogenomics to predict patient outcome. The Random Forest Survival model is able to predict patient survival based on apparent diffusion coefficients or gene expression data without any prior knowledge. 

260
Plasma 24
Multiparameter MRI Predictors of Extreme Survival in Glioblastoma Multiforme
Natarajan Raghunand1, Olya Stringfield2, John Arrington3, and Robert A Gatenby3

1Cancer Imaging & Metabolism, Moffitt Cancer Center, Tampa, FL, United States, 2IRAT Shared Service, Moffitt Cancer Center, Tampa, FL, United States, 3Diagnostic Imaging & Interventional Radiology, Moffitt Cancer Center, Tampa, FL, United States

We retrospectively analyzed initial MRI scans in two cohorts diagnosed with Glioblastoma Multiforme (GBM). The Long-Term Survival (LTS) cohort included 13 subjects who survived >36 months post-diagnosis, while the Short-Term Survival (STS) cohort included 12 subjects who survived ≤18 months. Tumor voxels were clustered by the normalized signal intensities on post-contrast T1w and FLAIR sequences into 6 distinct “habitats”. The LTS cohort were found to have a significantly higher fraction of Habitat 6 (high signal on T1w and FLAIR sequences) and lower fraction of Habitat 2 (low signal on T1w and high signal on FLAIR) compared with the STS cohort.

261
Plasma 25
Multi-Site Concordance of DSC-MRI Analysis for Brain Tumors:  Results of a NCI Quantitative Imaging Network DSC-MRI Collaborative Project
Kathleen M Schmainda1, Melissa A Prah1, Scott D Rand2, Mark Muzi3, Swati D Rane3, Xiao Da4, Yi-Fen Yen5, Jayashree Kalpathy-Cramer5, Thomas L Chenevert6, Dariya Malyarenko6, Benjamin Hoff6, Brian Ross6, Yue Cao7, Madhava P Aryal7, Bradley Erickson8, Panagiotis Korfiatis8, Laura Bell9, Leland Hu10, and Christopher Chad Quarles9

1Radiology, Medical College of Wisconsin, Milwaukee, WI, United States, 2Radiology, Medical College of Wisconsin, WI, United States, 3Radiology, University of Washington, WA, United States, 4Radiology, Massachusetts General Hospital, MA, United States, 5Radiology, Massachusetts General Hospital, Charlestown, MA, United States, 6Radiology, University of Michigan, Ann Arbor, MI, United States, 7Radiation Oncology, University of Michigan, Ann Arbor, MI, United States, 8Mayo Clinic, MN, United States, 9Barrow Neurological Institute, Phoenix, AZ, United States, 10Radiology, Mayo Clinic, Phoenix, AZ, United States

Though DSC-MRI perfusion is of well-known benefit for the evaluation of brain tumors, clinical translation has been hampered by a lack of confidence in the consistency of the derived RCBV (relative cerebral blood volume) and cerebral blood flow (CBF) values across sites and platforms.  This multi-site and multi-platform study, for which the same patient data set was analyzed, demonstrated substantial consistency in RCBV across software sites and platforms and the ability of each to distinguish low-grade from high-grade tumor. In addition, a single RCBV threshold was identified for which all platforms maintained good accuracy.  

262
Plasma 26
Perfusion-supervoxels for DCE-MRI based tumor subregion assessment
Benjamin John Irving 1, Jolanta Mirecka1, Ana L Gomes2, Danny Allen2, Paul Kinchesh2, Veerle Kersemans2, Stuart Gilchrist2, Sean Smart2, Julia A Schnabel3, Sir J Michael Brady2, and Michael Chappell1

1Institute of Biomedical Engineering, University of Oxford, Oxford, United Kingdom, 2Department of Oncology, University of Oxford, Oxford, United Kingdom, 3Division of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom

Tumors exhibit chaotic and leaky vasculature, which leads to variations in perfusion, and regions of edema, hypoxia and necrosis. We develop a method to extract perfusion-supervoxels, regions of locally similar perfusion, and use these regions with k-means clustering to define tumor subregions that are robust to noise and outliers. This method offers a number of advantages over both mean tumor parameters and voxelwise clustering.

263
Plasma 27
A New Combined Perfusion and Diffusion MRI Biomarker to Distinguish Pediatric High-Grade Glioma from Pilocytic Astrocytoma
Kathleen M Schmainda1, Melissa A Prah1, Jose A Palomares1, Mohit Maheshwari1, Sean Lew2, and Teresa Kelly1

1Radiology, Medical College of Wisconsin, Milwaukee, WI, United States, 2Neurosurgery, Medical College of Wisconsin, Milwaukee, WI, United States

Pediatric high-grade glioma (HGG) and pilocytic-astrocyoma/optic-pathway gliomas (PA+OPG) are each very vascular tumors but vary substantially in their treatment, clinical course and long term prognosis.  In this study we demonstrate that measurements that work in adults to distinguish tumor grades (eg RCBV) cannot distinguish between pediatric HGG and PA+OPG, but a new MRI biomarker, the ratio of standardized RCBV (sRCBV) to mean diffusivity (MD) can cleanly making this distinction.  This finding has significant implications for treatment management in the pediatric brain tumor population. 

264
Plasma 28
A ranking of pipelines for optimal co-registration of anatomical and diffusion weighted images of the cervical spinal cord
Stephanie Alley1, Francesco Grussu1, Marios C. Yiannakas1, Hugh Kearney1, Olga Ciccarelli1, Ferran Prados1,2, Sébastien Ourselin2, and Claudia AM Gandini Wheeler-Kingshott1,3,4

1UCL Institute of Neurology, Queen Square MS Centre, University College London, London, United Kingdom, 2Translational Imaging Group, Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom, 3Department of Brain and Behavioural Sciences, University of Pavia, Pavia, Italy, 4Brain MRI 3T Mondino Research Center, C. Mondino National Neurological Institute, Pavia, Italy

We conduct the first systematic evaluation of the performance of three widely used registration software toolkits (FLIRT from FSL, NiftyReg and ANTs employing Spinal Cord Toolbox) in an effort to outline a method for reliable co-registration between anatomical and quantitative (EPI-based) spinal cord MRI. We generate a diverse set of registration pipelines and rank them according to quality of co-registration metrics. We find that ANTs and NiftyReg outperform FLIRT, and we report heterogeneity of specifications for optimal co-registration among software toolkits.

265
Plasma 29
Deep-Neural-Network based image diagnosis: comparing various image preprocessing strategies to achieve higher accuracy and understanding of the decision
Yasuhiko Tachibana1, Takayuki Obata1, Jeff Kershaw1, Yoko Ikoma1, Tokuhiko Omatsu1, Riwa Kishimoto1, and Tatsuya Higashi2

1Applied MRI Research, Department of Molecular Imaging and Theranostics, National Institute of Radiological Sciences, Chiba, Japan, 2Department of Molecular Imaging and Theranostics, National Institute of Radiological Sciences, Chiba, Japan

The purpose of this study was to investigate how image preprocessing might help overcome two problems for deep-neural-network (DNN) based image diagnosis: the need for a large training database to achieve high accuracy and the difficulty humans have in understanding the internal decision process. Five DNNs were trained with a brain image series (preprocessed in five different ways), to judge the age-range of a volunteer. The performance of the DNNs was then compared statistically. The results suggested that image preprocessing may facilitate higher accuracy, and also make it easier to understand how and why a judgement was made.

266
Plasma 30
Cerebellum Tissue Segmentation with Ensemble Sparse Learning
Jiawei Chen1, Li Wang1, and Dinggang Shen1

1Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, NC, United States

Accurate segmentation of cerebellum is important in studying the structural changes in brain and the alert in different neuro-developmental disorders. However, cerebellum has received relatively little attention in the image processing literature, compared with cerebrum segmentation. In fact, cerebellum tissue segmentation is also very challenging due to severe partial volume effect and low contrast. In this study, an ensemble sparse learning is proposed for cerebellum tissue segmentation, where the goal is to segment the tissues in cerebellum into white matter (WM), gray matter (GM) and cerebrospinal fluid (CSF). The experiment results demonstrate that our proposed method show advantages in cerebellum tissue segmentation. 


Electronic Power Pitch Poster

Poster: Best of Cardiovascular MR: Hemodynamics & Atherosclerosis

Exhibition Hall Tuesday 9:15 - 10:15

332
Plasma 1
Utilizing Quantitative Measurements of Carotid Intraplaque Hemorrhage can Improve on Presence Alone in Classifying Patients with and without Acute Cerebral Infarcts
Li Dong1, Zhaoqi Zhang1, Wei Yu1, Sheng Wang2, Qiang Shen1, and Chun Yuan3

1Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, People's Republic of China, 2Department of Vascular disease, Beijing Anzhen Hospital, Capital Medical University, Beijing, People's Republic of China, 3Department of Radiology, University of Washington, Seattle, WA, United States

Histological studies have shown that intraplaque hemorrhage (IPH) size might be important in assessing disease severity. We hypotheses that the quantitative measurements of IPH by MRI provide additional value towards classify acute cerebral infarcts (ACI) in the carotid territory by brain MRI. We found that the subjects with ACI had larger max % IPH measurements (AUC=84.7%, p=0.015) and IPH closer to the lumen (AUC=85.4%, p=0.012). Further, using the size and distance measurements simultaneously improved the AUC to 96.9%. Beyond the presence of IPH, quantitative measurements of IPH may improve the predictive value of carotid plaque imaging for future stroke.

333
Plasma 2
Whole-Brain Vessel Wall MR Imaging Using Inversion-Recovery Prepared SPACE: Reproducibility and Accuracy of Intracranial Artery Morphology
Na Zhang1,2, Fan Zhang1, Zixin Deng1, Qi Yang1, Xiaoming Bi3, Debiao Li1, Xin Liu2, and Zhaoyang Fan1

1Biomedical Imaging Research Institute, Cedars Sinai Medical Center, Los Angeles, CA, United States, 2Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, People's Republic of China, 3Siemens Healthcare

Intracranial atherosclerosis disease is one of the main causes for cerebrovascular events. A T1-weighted whole-brain vessel wall imaging method, inversion-recovery prepared SPACE (IR-SPACE), was developed at 3T demonstrating advantages over conventional SPACE. This study was aimed to determine the reproducibility of scan-rescan, intra-, and inter-observer as well as the accuracy when using the technique for morphology assessment of the intracranial vessel wall. In general, this study demonstrated excellent reproducibility and good agreement between the 3D and 2D techniques. In conclusion, IR-SPACE is a reproducible and accurate MR method for intracranial vessel wall imaging.

334
Plasma 3
A Preliminary Report on Time-Resolved Coronary Vessel Wall MRI in Heart Transplant Recipients
Giulia Ginami1,2, Jerome Yerly1,3, Jessica AM Bastiaansen1, Ruud B van Heeswijk1, Nathalie Lauriers4, Juan F Iglesias5, Sophie Degrauwe5, Andrea Zuffi5, Roger Hullin5, and Matthias Stuber1,3

1Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland, 2Division of Imaging Sciences and Biomedical Engineering, King’s College London, London, United Kingdom, 3Centre for Biomedical Imaging (CIBM), Lausanne, Switzerland, 4Department of Radiology, University Hospital (CHUV) of Lausanne, Lausanne, Switzerland, 5Service de Cardiologie, University Hospital (CHUV) of Lausanne, Lausanne, Switzerland

In this study, we applied a recently developed and robust coronary vessel wall MRI method that includes a golden angle trajectory and k-t sparse SENSE to a cohort of heart transplant patients. The coronary vessel wall was visualized with high contrast in all patients and the method holds great promise for quantitative and non-invasive characterization of coronary allograft vasculopathy (CAV) in transplanted patients.

335
Plasma 4
Non-Gadolinium-Contrast Relaxation-Enhanced MR Angiography in Children with an Inversion Recovery and T2-Prepared 3D mDIXON Gradient-Echo Technique: Preliminary Experience
Amber L. Pokorney1, Jonathan M. Chia2, Dianna ME Bardo1, Mittun Patel1, Smita S. Bailey1, Scott Jorgensen1, Deepa Biyyam1, Scott Willard1, Jeffrey H. Miller1, Houchun Harry Hu1, and Masami Yoneyama3

1Radiology, Phoenix Children's Hospital, Phoenix, AZ, United States, 2Philips HealthTech, Dallas, TX, United States, 3Philips Electronics, Tokyo, Japan

We demonstrate the preliminary clinical feasibility and utility of a 3D non-Gadolinium MR angiography sequence called REACT (Relaxation-Enhanced MR Angiography without Contrast and Triggering) in 21 pediatric patients (age range: 1.7 – 16.1 years).  REACT, which collectively utilizes T2-preparation, inversion recovery, and water-fat separation to suppress unwanted signals and exploit the long T1 and T2 times of unenhanced blood, is particularly beneficial in children, a population where Gadolinium administration should be minimized given recent concerns with residual intracranial Gadolinium deposition.  We illustrate and compare REACT to Gadolinium-based MRA in the neck, upper and lower extremities, and the chest, abdomen, and pelvis.

336
Plasma 5
Ultra-High Spatiotemporal Resolution 4D Flow for Valve and Coronary Arterial Delineation
Shreyas S. Vasanawala1, Furhawn Shah1, Marcus T. Alley1, and Joseph Y. Cheng1

1Department of Radiology, Stanford University, Stanford, CA, United States

4D flow provides single sequence rapid protocol for assessment of blood flow, ventricular function, and anatomy in congenital heart disease. Though valve function has been well validated for regurgitant flow fraction, assessment of valve leaflet delineation has been limited by relatively low spatiotemporal resolution. Similarly, coronary origin delineation has been limited. Here, we develop an ultra-high spatiotemporal resolution 4D flow acquisition technique and assess its performance for valve and coronary delineation. 4D flow provides superior delineation of coronaries than echo, is highly likely to depict coronary origins, and is highly likely to provide good valve leaflet delineation.

337
Plasma 6
Noninvasive Functional Evaluation of Coronary Stenosis Using MR Instantaneous wave-Free Ratio (MR-iFR): Pilot patient study using invasive fractional flow reserve as a reference
Zixin Deng1,2, Sang-Eun Lee3, Zhaoyang Fan1, Christopher Nguyen1, Yibin Xie1, Jianing Pang1, Xiaoming Bi4, Qi Yang1, Byoung-Wook Choi5, Jung-Sun Kim3, Daniel Berman1, Hyuk-Jae Chang3, and Debiao Li1

1Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States, 2Bioengineering, University of California, Los Angeles, Los Angeles, CA, United States, 3Cardiology, Severance Cardiovascular Hospital, 4Siemens Healthcare R&D, 5Radiology, Severance Cardiovascular Hospital

In patients with suspected coronary artery disease undergoing invasive coronary angiography, approximately half has nonsignificant stenosis (stenotic lesions that may not induce ischemia), leading to frequent and unnecessary invasive procedures.  Previously, we proposed a noninvasive technique for functional evaluation of coronary stenosis using PC-MRI and navier-stokes equations. In this study, we evaluated the feasibility of the technique in patients, using invasive fractional flow reserve as a reference. Good correlation was observed between noninvasive and invasive techniques with high specificity and negative-predictive-value, demonstrating the potential of the proposed technique in identifying patients with functionally nonsignificant stenosis and eliminating unnecessary invasive procedures. 

338
Plasma 7
Analysis of 4D flow hemodynamics parameters in BAV patients using a finite element method
Julio Sotelo1,2, Lydia Dux-Santoy3, Andrea Guala3, Jose Rodríguez-Palomares3, Arturo Evangelista 3, Daniel Hurtado4, and Sergio Uribe5

1Biomedical Imaging Center, Pontificia Universidad Católica de Chile, Santiago, Chile, 2Department of Electrical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile, 3Department of Cardiology, Hospital Universitari Vall d´Hebron. Vall d´Hebron Institut de Recerca (VHIR). Universitat Autònoma de Barcelona., Barcelona, Spain, 4Department of Structural and Geotechnical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile, 5Department of Radiology, School of Medicine, Pontificia Universidad Católica de Chile, Santiago, Chile

Bicuspid aortic valve (BAV) is one the most common cardiac defect. The progression of the defect can vary with the time and may lead to ventricular dysfunction, heart failure and death of the patient. In this work we proposed a method to obtain several hemodynamics parameters including WSS, OSI, vorticity, helicity density, viscous dissipation, energy loss and kinetic energy from 4D-flow data sets of BAV patients and healthy volunteers using a finite-element approach. We found that the viscous dissipation, helicity density, vorticity, WSS and energy loss are the most relevant hemodynamics parameters in the ascending aorta of those patients. 

339
Plasma 8
Phase-Contrast MRI with Hybrid One- and Two-sided Flow-Encoding and Velocity SPectrum SepAration (HOTSPA)
Da Wang1,2, Jiaxin Shao1, Daniel B. Ennis1,2,3, and Peng Hu1,2

1Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA, United States, 2Biomedical Physics Interdepartmental Graduate Program, University of California, Los Angeles, Los Angeles, CA, United States, 3Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, United States

In this work, we propose a new and more efficient flow encoding and velocity calculation strategy for PC-MRI using a temporal modulation technique to double the temporal resolution or reduce the scan time by 50%. This is the first study to examine a temporal modulation strategy for an under-sampled M1-space (gradient first moment space including FC, FEx, FEy and FEz encoding steps). Our strategy can be combined with conventional acceleration techniques, i.e. parallel imaging and compressed sensing, to further shorten the scan time of PC-MRI. 

340
Plasma 9
Association between Carotid Atherosclerotic Plaque Calcification and Intraplaque Hemorrhage: A High Resolution Magnetic Resonance Imaging Study
Shuo Chen1, Ruolan Lin2, Gaifen Liu3, Rui Li1, Yunjing Xue2, and Xihai Zhao1

1Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, People's Republic of China, 2Department of Radiology, Fujian Union Hospital, People's Republic of China, 3Department of Neurology, Beijing Tiantan Hospital, Capital Medical University, People's Republic of China

Carotid intraplaque hemorrhage (IPH) is associated with cardiovascular events. Calcification, frequently accompanied with IPH, may play a role in occurrence of IPH. In this study we aimed to investigate the associations between calcification characteristics and IPH in carotid plaques. Our results suggest that surface calcification and multiple calcification in carotid atherosclerotic plaques are independently associated with presence IPH. Both quantity and location of calcification may play important roles in occurrence of IPH. These findings may provide novel insights for understanding the mechanism of IPH.

341
Plasma 10
Association between Age of Intraplaque Hemorrhage and Fibrous Cap Rupture in Carotid Artery Atherosclerosis: A High Resolution Magnetic Resonance Imaging Study
Yuanyuan Cui1, Xihai Zhao2, Huiyu Qiao2, Dongxiang Xu3, Mingming Lu1, Xiaoyi Chen2,4, Lu Ma1, and Jianming Cai1

1Department of Radiology, The General Hospital of People’s Liberation Army (301 hospital), Beijing, People's Republic of China, 2Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University, Beijing, People's Republic of China, 3Department of Radiology, University of Washington, Seattle, United States, 4Beijing Institute for Brain Disorders, Capital Medical University, Beijing, People's Republic of China

It has been shown that presence of carotid artery intraplaque hemorrhage (IPH) is associated with fibrous cap rupture (FCR), which is one of the major causes of ischemic cerebrovascular events. However, the role of different age of IPH in occurrence of IPH remains unclear. This study investigated the association between the age of IPH and FCR in carotid arteries using MR imaging. We found that fresh IPH volume was independently associated with FCR (odds ratio: 1.826; 95% CI: 1.130-2.949; P=0.014). Compared with recent IPH, fresh IPH was a stronger predictor for FCR (area under the curve: 0.79 vs. 0.64). 

342
Plasma 11
Compressed Sensing based Simultaneous Black- and Gray-blood Carotid Vessel Wall MR Imaging
Bo Li1,2, Hao Li3, Guofu Huang1, Xia Qian1, Wei Wang1, and Li Dong4

1Center Laboratory, The First Hospital of Nanchang City, Nanchang, People's Republic of China, 2Department of Radiology, The Third Affiliated Hospital of Nanchang University, Nanchang, People's Republic of China, 3Department of Radiology, University of Cambridge, Cambridge, United Kingdom, 4Department of Radiology, Beijing Anzhen Hospital, Beijing, People's Republic of China

We sought to achieve high-quality simultaneous black- and gray-blood MR imaging using the CS based dual contrast imaging technique proposed on 2015. The performances on the blood suppression efficiency, image quality and morphological measurements for the CS based dual-contrast imaging technique were investigated. Seven healthy volunteers and five patients with carotid artery stenosis were recruited in this study. STR, CTR were calculated. LA and WA were measured. The comparisons for the black- and gray-blood image quality and the presence of plaque calcifications were implemented. This technique provides spatially matched black- and gray- images and excellent visualization for vessel wall imaging.

343
Plasma 12
Comparison of acceleration algorithms in whole-heart 4D flow MRI for aortic and mitral valve flow assessment
Jos Westenberg1, Pankaj Garg2, Pieter van den Boogaard1, and Sven Plein2

1Radiology, Leiden University Medical Center, Leiden, Netherlands, 2University of Leeds, Leeds, United Kingdom

Accelerated acquisition is required to make 4D flow MRI clinically feasible. In this study, three commonly used acceleration approaches are compared. Validation of flow volume and velocity assessment is performed in phantoms and comparison against conventional 2D phase-contrast is done across the aortic and mitral valve in 25 healthy volunteers. 4D flow MRI with echo-planar-imaging shows largest in vitro error in velocity assessment, however, the bias is within clinically acceptable margins. In volunteers, 4D flow MRI with echo-planar-imaging produces most reliable quantitative results in flow volume and velocity and presents the shortest acquisition time with satisfactory image quality.

344
Plasma 13
Golden Step, Golden Angle, Spiral-Cartesian Imaging for Flexible Gated Three-dimensional Angiography
Grzegorz Tomasz Kowalik1, Jennifer Anne Steeden1, David Atkinson2, Kristian Mortensen3, and Vivek Muthurangu1,3

1Institute of Cardiovascular Science, University College London, London, United Kingdom, 2Centre for Medical Imaging, Division of Medicine, University College London, London, United Kingdom, 3Great Ormond Street Hospital for Children, London, United Kingdom

The purpose of this study was to develop and validate a novel 3D hybrid spiral-Cartesian MR angiographic sequence that utilized a golden step, golden angle acquisition strategy to enable flexible reconstruction.

We demonstrate that it is possible to acquire GSA-MRA and reconstruct it in a flexible manner (Real-time and cardiar and/or respiratory gated reconstructions). This may enable better interrogation of anatomy.

The new flexible 3D MRA provide novel ways of assessing cardiac disease.


345
Plasma 14
Distribution of Intraluminal Thrombus Composition in Abdominal Aortic Aneurysms by Diameter: a High Resolution MRI study
Chengcheng Zhu1, Bing Tian2, Joseph Leach1, Qi Liu2, Jianping Lu2, David Saloner1, and Michael D Hope1

1Radiology, University of California, San Francisco, San Francisco, CA, United States, 2Radiology, Changhai Hospital, Shanghai, People's Republic of China

Intraluminal thrombus (ILT) composition as identified by MRI has been suggested to be a marker of likely abdominal aortic aneurysm (AAA) progression. However, little is known about the distribution of ILT composition across different sizes of AAAs. This study investigated the ILT composition by AAA diameter in 62 patients from two centers. We found ILT distributed differentially by size, with an increasing mix of fresh and old ILT in larger AAAs. ILT composition is a potential indicator of AAA progression. Larger, prospective studies are needed to clarify its prognostic value in managing AAA patients. 

346
Plasma 15
Evaluation of Portal Vein System in patients after liver transplantation by Unenhanced MR Angiography Using Spatial Labeling with Multiple Inversion Pulses Sequence and by CT portography
hao tang1, daoyu hu, xiaoyan meng, zi wang, zhen li, and yanchun wang

1Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, People's Republic of China

Unenhanced MR angiography with spatial labeling with multiple inversion pulses (SLEEK) is a reliable method for depicting portal vein system in patients with liver transplantation compared with computed tomographic portography (CTP) results. In a study of 20 patients who underwent liver transplantation, we found that there was excellent correlation between SLEEK and CTP in presenting the diameter of portal vein. Unenhanced MRA using SLEEK is relatively inexpensive and is not associated with renal complications. It can be as a good choice for screening portal vein system in patients with liver transplantation, especially in patients with renal insufficiency.


Electronic Power Pitch Poster

Poster: Brain Physiology: Flow, Oxygen, Metabolism

Exhibition Hall Tuesday 9:15 - 10:15

347
Plasma 16
Long-term Cerebrovascular Dysfunction Following Repeated Mild Traumatic Brain Injury
Conner Adams1,2, Margaret Koletar1, Tina L. Beckett1, Lindsay Cahill3, Lydiane Hirschler4,5,6, Jan M. Warnking4,6, Emmanuel L. Barbier4,6, JoAnne McLaurin1,7, John G. Sled2,3, and Bojana Stefanovic1,2

1Sunnybrook Research Institute, Toronto, ON, Canada, 2Medical Biophysics, University of Toronto, Toronto, ON, Canada, 3Mouse Imaging Centre, The Hospital For Sick Children, Toronto, ON, Canada, 4Grenoble Institut des Neurosciences, Université Grenoble Alpes, Grenoble, France, 5Bruker Biospin MRI, Ettlingen, Germany, 6Inserm, U1216, Grenoble, France, 7Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON, Canada

Pseudo-Continuous Arterial Spin Labelling (pCASL) was used to assess cerebrovascular dysfunction of mice having traumatic brain injury (TBI) - which had been induced via serial controlled cortical impacts. Resting perfusion was quantified in absolute units via multiple post-label-delay pCASL experiments, and found to be reduced in the lesion. Furthermore, vascular reactivity to hypercapnic challenge, assessed via pCASL, appears to be enhanced in initial results. These results, in conjunction with immunohistochemical analysis and T2-weighted structural images, imply severe damage due to TBI, with vascular adaptation in the form of angiogenesis as the response from the brain.

348
Plasma 17
Comparative Study of 3D Arterial Spin Labeling and dynamic contrast-enhanced MRI of Nasopharyngeal Carcinoma perfusion imaging
Bohan Xiao1, Zhaoxiang Ye1, Peiguo Wang1, Ying Liu1, Yingyu Zhao1, and Dandan Zheng2

1Key Laboratory of Cancer Prevention and Therapy, Department of Radiology, Tianjin Medical University Cancer Institute & Hospital, Tianjin, People's Republic of China, 2MR Research China, GE Healthcare, Beijing, People's Republic of China

DCE-MRI is already a standard approach to evaluating tumor perfusion in NPC, but it may induce severe side-effects. ASL is a noninvasive MRI technique that has been mainly used to achieve perfusion imaging in central nerve system. In this study, we attempt to evaluate the application of ASL in NPC. Thirty-eight newly diagnosed NPC patients underwent 3D ASL and DCE-MRI perfusion scans on a 3.0-T MRI system. ASL BF value and DCE-MRI parameters were calculated and compared. Statistically significant correlation was found between them. Therefore, 3D ASL may provide a potential alternative to DCE-MRI in NPC diagnosis and therapy evaluation.

349
Plasma 18
Non-contrast vascular compliance mapping using time-resolved VASO CBV imaging
Yang Li1,2, Deng Mao1,2, Jay J. Pillai1, and Hanzhang Lu1

1Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD, United States, 2Graduate School of Biomedical Sciences, UT Southwestern Medical Center, Dallas, TX, United States

Vascular compliance reflects the stiffness of arterial vessel wall and has been related to a number of diseases, such as cardiovascular disease, cerebral arteriosclerosis, and hypertension. However, the vascular compliance at intracranial arteries has been rarely measured due to limited availability of effective methods. In this work, a 3D VASO-CBV-based MR technique was developed to assess the arterial CBV change with respect to pulsation and thus estimate vascular compliance. With this technique, we were able to map vascular compliance along the intracranial arterial tree.

350
Plasma 19
Propagation Patterns of Cardiac-driven and Respiratory-driven Cerebrospinal Fluid Velocity Waves Characterized by Correlation Mapping in Conjunction with Asynchronous 2-Dimensional Phase Contrast Technique
Satoshi Yatsushiro1, Saeko Sunohara2, Mitsunori Matsumae3, and Kagayaki Kuroda1,2

1Graduate School of Science and Technology, Tokai University, Hiratsuka, Kanagawa, Japan, 2Graduate School of Engineering, Tokai University, Hiratsuka, Kanagawa, Japan, 3Department of Neurosurgery, Tokai University School of Medicine, Isehara, Kanagawa, Japan

Spatial distributions of the propagation patterns of cerebrospinal fluid (CSF) motion driven by cardiac pulsation and respiration were visualized using velocity waveform correlations based on asynchronous 2-dimensional phase contrast (2D-PC) imaging. These two different driving mechanisms were evaluated using spectral analysis of the velocity waveforms for 11 healthy subjects. Delay time maps and maximum correlation maps showed the spatial distribution differences between the cardiac-driven and respiratory-driven CSF motion propagations. Maximum correlation at the prepontine was 0.83±0.05 for cardiac propagation and 0.74±0.04 for respiratory propagation with a significant difference (p << 0.01). Strong propagation may not necessarily cause large CSF displacement.

351
Plasma 20
Regionally differentiated cerebral blood flow increases during infancy measured with pCASL MRI
Qinlin Yu1,2,3,4, Huiying Kang1,5, Minhui Ouyang1,2, Yun Peng5, Fang Fang3,4, and Hao Huang1,2

1Department of Radiology, Children’s Hospital of Philadelphia, Philadelphia, PA, United States, 2Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, United States, 3School of Psychological and Cognitive Sciences, Peking University, Beijing, People's Republic of China, 4Peking-Tsinghua Center for Life Science, Peking University, Beijing, People's Republic of China, 5Department of Radiology, Beijing Children’s Hospital, Capital Medical University, Beijing, People's Republic of China

During infant brain development, rapid neuronal growth requires increases of cerebral blood flow. In this study, we quantified cerebral blood flow (CBF) at regional level during infant development by using pseudo-continuous arterial spin labeled (pCASL) perfusion MRI. The CBF maps at different infant stages from 0 to 24 months were revealed. The trend lines of CBF at specific regions were charted. It has been found that the CBF increases linearly at different brain regions, with CBF increasing faster in visual, posterior cingulate, medial prefrontal and inferior parietal cortex than whole brain. 

352
Plasma 21
Cerebral blood flow as a marker for cortical parcellation
Roy Haast1, Dimo Ivanov1, Elia Formisano1, and Kâmil Uludağ1

1Department of Cognitive Neuroscience, Maastricht University, Maastricht, Netherlands

Within-subject differences of T1, T2* and cortical thickness can be used to automatically parcellate the cortex, e.g. to guide functional analyses or increase statistical power. Here, we evaluate the additional benefit of baseline CBF as a marker for brain metabolism to differentiate regions. We demonstrate that CBF data is not redundant with the other quantitative MRI parameters. Therefore, a data-driven parcellation of brain regions that incorporates perfusion information allows delineation of the cortex into smaller units and enhances subsequent anatomical & functional analysis.

353
Plasma 22
Changes in cerebral blood flow and default mode network connectivity following mTBI observed with pulsed arterial spin labeling
Natalie M. Wiseman1, Armin Iraji2, E. Mark Haacke2,3, and Zhifeng Kou2,3

1Department of Psychiatry and Behavioral Neurosciences, Wayne State University, Detroit, MI, United States, 2Department of Biomedical Engineering, Wayne State University, Detroit, MI, United States, 3Department of Radiology, Wayne State University, Detroit, MI, United States

Mild traumatic brain injury (mTBI) or concussion disturbs both cerebral blood flow (CBF) and functional connectivity in intrinsic connectivity networks (ICNs). Using pulsed arterial spin labeling (PASL), we derived both CBF and ICNs in mTBI patients and investigated brain CBF responses to network disruptions. We observed that mTBI patients have decreased connectivity within the default mode network (DMN) in two regions as well as increased CBF in a third region which overlaps the DMN. The mismatch of these regions suggests potential repair or compensation for injury.

354
Plasma 23
A Novel Approach to Measuring Cerebral Oxygen Extraction Fraction and Vascular Reserve Using MRI
Charles Cantrell1, Yong Jeong2, Kevin Midlash3, Parmede Vakil2, Sameer Ansari2, and Timothy J Carroll3

1Northwestern University, Chicago, IL, United States, 2Northwestern University, 3University of Chicago

The length scales associated with parenchymal oxygen extraction fraction (OEF), coupled with the near uniformity of normative OEF across the brain dictate the development of an imaging approach that is sensitive to low-spatial frequency imaging behavior. Previous approaches to measure OEF using MRI have utilized high pass-filters—effectively removing much of the signal.  We propose a new method to filter out geometric field inhomogeneity, by imaging temporally through the cardiac cycle.  In a study in 11 patients with intracranial atherosclerotic disease, we found elevated OEF on the compromised hemisphere as compared to the healthy contralateral side (p<0.0195).

355
Plasma 24
Measurements of Oxygen Delivery and Consumption  Using Hematocrit Derived from Blood T1 Quantification
Feng Xu1,2,3, Wenbo Li1,2, Peiying Liu1,2, Hanzhang Lu1,2, John J. Strouse4, James J Pekar1,2, Peter C.M. van Zijl1,2, and Qin Qin1,2

1F.M. Kirby Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, United States, 2The Russell H. Morgan Department of Radiology and Radiology Science, Johns Hopkins University, Baltimore, MD, United States, 3Developing Brain Research Laboratory, Children's National Medical Center, Washington DC, DC, United States, 4Department of Medicine, Duke University, Durham, NC, United States

We verified that venous blood T1 quantified in vivo in humans using fast and non-invasive MRI can be used to derive hematocrit (Hct) values reliably. This Hct information can be used for a more individual estimation of oxygen extraction fraction (OEF) from venous blood T2 measurements. Furthermore, inverse correlation between Hct and baseline cerebral blood flow (CBF) was observed across subjects. Measurement of Hct, OEF and CBF allowed determination of oxygen delivery (OD~CBF∙Hct) and consumption (cerebral metabolic rate of oxygen, CMRO2~CBF∙Hct∙OEF). When compared to CBF, OD and CMRO2 showed less inter-subject variations among normal volunteers.

356
Plasma 25
Simultaneous cerebral blood flow and bold oxygen level dependent signal assessments using multi-band multi-echo pseudo-continuous arterial spin labeling (M2-PCASL)
Shiyang Chen1, Junjie Wu2, Kyle Pate2, Xiaodong Zhong2,3, Bruce Crosson2,4, and Deqiang Qiu2

1Georgia Institute of Technology, Atlanta, GA, United States, 2Department of Radiology and Imaging Sciences, Emory University, Atlanta, GA, United States, 3MR R&D Collaborations, Siemens Healthcare, Atlanta, GA, United States, 4Department of Neurology, Emory University, Atlanta, GA, United States

We proposed a novel multi-band multi-echo pseudo-continuous arterial spin labeling (M2-PCASL) method to simultaneously measure the cerebral blood flow (CBF) and the blood oxygen level dependent (BOLD) signal. Increased spatial resolution was achieved compared to the conventional method, and experiments were also conducted to show simultaneous measurement of CBF and BOLD signal dynamics in response to hypercapnia. M2-PCASL can be a useful tool for measuring cerebrovascular reactivity and studying neurovascular coupling in various conditions.

357
Plasma 26
Measuring Blood Oxygenation and Hematocrit with a Combined T2 and T1 Approach: Initial Experience in Humans
Thomas Christen1, Jia Guo1, Wendy Wei Ni1, Michael Moseley1, and Greg Zaharchuk1

1Radiology, Stanford University, Palo Alto, CA, United States

In this study, we propose to obtain simultaneous measurements of blood oxygen saturation (SO2) and hematocrit (Hct) by combining two or more in vivo measurements of blood MR relaxation times. We tested our approach in 5 healthy human subjects using T2+T1 values and calibration curves obtained in vitro. The results found in the superior sagittal sinus vein (SO2=62±5% and Hct=46±1%) are in good agreement with literature values and suggest great potential of the approach once it is further validated.

358
Plasma 27
Whole-Brain Arteriography and Venography Using an Improved Velocity-Selective Saturation (VSS) Pulse Trains
Wenbo Li1,2, Feng Xu 1,2,3, Jing Liu1,4, Michael Schär1, Taehoon Shin5, Peter van Zijl1,2, Ye Qiao1, Bruce Wasserman1, and Qin Qin1,2

1Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD, United States, 2F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, United States, 3Developing Brain Research Lab, Children’s National Medical Center, Washington, DC, United States, 4Department of Radiology, People’s Hospital, Guangzhou, People's Republic of China, 5Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland, Baltimore, MD, United States

Velocity-selective (VS) MRA, a non-subtractive technique and allows large spatial coverage and slow-flow depiction has shown recent promise for cerebral applications at 3T. Here, we improved the velocity-selective saturation (VSS) pulse train by reducing its sensitivity of tissue suppression to B1 inhomogeneity for both the intracranial and cervical regions. Moreover, we propose that arteriograms or venograms can be obtained by placing spatially selective inversion pulses before the acquisition to selectively null signals from venous or arterial blood. The feasibility of these technical advances for VS MRA is demonstrated on healthy volunteers at 3T.

359
Plasma 28
Simultaneous acquisition of oxygen extraction fraction and cerebral blood flow during brain activation
Yayan Yin1, Yaoyu Zhang1, Yang Fan2, Bing Wu2, and Jia-Hong Gao1

1Center for MRI Research, Peking University, Beijing, People's Republic of China, 2MR Research China, GE Healthcare, Beijing, People's Republic of China

The development of neuroimaging methods to obtain oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO2) is crucial for understanding mechanisms underlying physiological function and neuronal activity. In the present study, a novel technique termed FAIR-MGESSE combined flow sensitive alternating inversion recovery (FAIR) and multiecho gradient echo sampling of the spin echo (MGESSE) techniques. It is proposed for acquiring OEF and ASL maps in a single repetition time to determine the relative change in CMRO2 in human subjects. Relative changes in CBF, OEF and CMRO2 were measured during the visual task and the results agree well with expectations.

360
Plasma 29
A Method for Quantitative Cerebrovascular Reserve
Yong Ik Jeong1, Charles G Cantrell1, Kevin Midlash2, Renee Qian, Parmede Vakil3, Sameer A Ansari3, Gregory Christoforidis2, and Timothy J Carroll2

1Northwestern University, Evanston, IL, United States, 2University of Chicago, 3Northwestern University

In the occurrence of damage to the hemodynamic system of the brain, a response is elicited by changes in the supply of blood and oxygen to the tissue. Depending on these different changes, the severity of the hemodynamic impairment can be defined. In this study, we propose a method of accurately measuring quantitative cerebrovascular reserve. This is achieved by applying water correction factors to multiple contrast-agent injection cerebral blood flow measurements. In multiple studies involving volunteers, animal model, and patients, we confirm the correction factors and compare against microsphere perfusion.

361
Plasma 30
Robust Visualization of MCA Main Trunk by Improved Acceleration-Selective Arterial Spin Labeling (iAccASL) for Intracranial MR Angiography
Yuta Akamine1, Makoto Obara1, Osamu Togao2, Shuhei Shibukawa3, Masami Yoneyama1, Tomoyuki Okuaki4, and Marc Van Cauteren4

1Philips Electronics Japan, Shinagawa, Tokyo, Japan, 2Department of Clinical Radiology, Graduate School of Medical Science, Kyushu University, Fukuoka, Japan, 3Department of Radiology, Tokai University Hospital, Japan, 4Asia Pacific, Philips Healthcare, Shinagawa, Tokyo, Japan

Improved acceleration-selective arterial spin labelling (iAccASL) was implemented for Intracranial MR angiography and images were acquired in six healthy volunteers. Additional 180゜refocusing pulses in control module will efficiently suppress spin dispersion and flow voids in strongly accelerating middle cerebral artery (MCA) main arteries. The vessel visualizations of MCA main trunk and peripheral vessels were compared with our previously reported AccASL and conventional time-of-flight (TOF) approach. We demonstrated iAccASL could produce better MCA main trunk visualization (without venous signal) compared with conventional AccASL technique with better peripheral visualization than TOF.


Electronic Power Pitch Poster

Poster: Liver

Exhibition Hall Tuesday 14:45 - 15:45

426
Plasma 1
Relationship between hepatic blood flow and segmental liver hypertrophy after portal vein embolization using 4D flow MRI
Tilman Schubert1, Kevin Johnson2, Alejandro Roldan Alzate1, and Scott Reeder1,2

1Radiology, UW Wisconsin Madison, Madison, WI, United States, 2Medical Physics, UW Wisconsin Madison, Madison, WI, United States

This study used 4D-flow MRI to assess potential correlations between changes in portal-venous blood flow and liver growth after portal vein embolization (PVE). 4 pigs underwent PVE and were examined with 4D flow MRI before and immediately after PVE as well as 1 week and 2 weeks after PVE. The results indicate that a persistent increase in blood flow volume to non-embolized liver segments as opposed to a peak in flow volume that later decrease over time, is likely to influence growth of these segments. Furthermore, 4D-flow MRI is well suited to study changes in portal-venous flow volume after PVE.

427
Plasma 2
Proton Density Fat Fraction Estimation Accuracy of High-Flip-Angle, Contrast-Enhanced, Magnitude-Based Multi-Gradient-Echo MR Imaging at 3T
Ethan Z Sy1, Cheng William Hong1, Soudabeh Fazeli Dehkordy1, Charlie C Park1, Alexandra Schlein1, Jonathan C Hooker1, Jennifer Cui1, Gavin Hamilton1, and Claude B Sirlin1

1University of California, San Diego, San Diego, CA, United States

Proton density fat fraction (PDFF) is a widely-used magnetic resonance imaging (MRI)-based biomarker for noninvasive quantification of hepatic steatosis. PDFF derived from low-flip-angle magnitude-based multi-gradient-echo MRI (MRI-M) without intravenous contrast has been shown to have high accuracy for estimating fat fraction. However, this MRI-M technique has a relatively low signal-to-noise ratio (SNR), which makes it difficult to visualize anatomical features. In this analysis of ninety-two patients, high-flip-angle contrast-enhanced (with either gadoxetate disodium or gadobutrol) MRI-M imaging had no significant difference in fat-grading accuracy from the standard low-flip-angle pre-contrast PDFF, using MR spectroscopy (MRS)-PDFF as the reference standard.

428
Plasma 3
Assessment of liver function using an uptake ratio based on multiple-time points  hepatocyte mapping
Tomoyuki Okuaki1, Kosuke Morita2, Tomohiro Namimoto3, Morikatsu Yoshida3, Shinya Shiraishi3, Yasuyuki Yamashita3, and Marc Van Cauteren1

1MR Clinical Science, Philips Healthtech, Tokyo, Japan, 2Department of Central Radiology, Kumamoto University Hospital, Kumamoto, Japan, 3Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan

We calculated the uptake fraction (kHep) based on a pharmacokinetics model of gadolinium ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA) uptake using R1 changes in the hepatocyte. The kHep and ΔT1 values were compared to indexes determined by 99mTc-GSA scintigraphy for three different scan time points. The correlation coefficients of the blood clearance indexes (HH15) and receptor indexes (LHL15) were 0.307 and 0.497 for the ΔT1 and 0.537 and 0.570 for kHep values, respectively. The results indicate that the proposed quantification value of kHep is a more robust index for liver function compared with the ΔT1 value.

429
Plasma 4
Detection of Advanced Liver Fibrosis and Cirrhosis using MR elastography compared to liver surface nodularity measurement, EOB-DTPA uptake and blood tests
Cecilia Besa1, Mathilde Wagner1,2, Grace Lo1, Sonja Gordic1, Manjil Chatterji1, Ashley Stueck3, James Babb4, Andrew Smith5, and Bachir Taouli1

1Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, United States, 2Radiology, Groupe Hospitalier Pitié Salpêtrière, Paris, France, 3Pathology, Icahn School of Medicine at Mount Sinai, New York, NY, United States, 4Radiology, New York University Langone Medical Center, New York, United States, 5Radiology, University of Mississippi Medical Center, Jackson, MS, United States

This study compares the diagnostic performance of multiparametric MRI including qualitative and quantitative assessment of MR-elastography (MRE), liver surface nodularity (LSN) software measurement, hepatic enhancement ratios on Gd-EOB-DTPA (EOB-ER), and serum markers (APRI and FIB4) for the detection of liver fibrosis and cirrhosis. When comparing different MRI methods and serum markers with histologic findings, liver stiffness measured with MRE showed better performance than other methods for detection of advanced liver fibrosis and cirrhosis, especially when combined with blood tests (FIB4).

430
Plasma 5
Diagnostic performance of LI-RADS major features, ancillary features, and categories on MRI for diagnosis of hepatocellular carcinoma
Milena Cerny1, Catherine Bergeron1, Jean-Sébastien Billiard1, Jessica Murphy-Lavallée1, Damien Olivié1, Joshua Bérubé1, Boyan Fan1, Hélène Castel2, Simon Turcotte3, Pierre Perrault1, and An Tang1,4

1Department of Radiology, Centre hospitalier de l'Université de Montréal (CHUM), MONTREAL, QC, Canada, 2Department of Gastroenterology and Hepatology, Centre hospitalier de l'Université de Montréal (CHUM), MONTREAL, QC, Canada, 3Department of Surgery, Centre hospitalier de l'Université de Montréal (CHUM), MONTREAL, QC, Canada, 4Centre de recherche du Centre hospitalier de l'Université de Montréal (CRCHUM), MONTREAL, QC, Canada

Diagnosis of hepatocellular carcinoma (HCC) is largely based on imaging. MRI is ideally suited for the non-invasive diagnosis of HCC because it has numerous tissue contrast mechanisms and is the only modality that can assess all major and ancillary imaging features. We evaluated the diagnostic performance of MRI-determined LI-RADS major features, ancillary features, and categories for the diagnosis of HCC. Our results suggest that interpretation that includes ancillary features increases the sensitivity, while preserving a high specificity for definite HCC and a slightly lower specificity for probable HCC. Further, ancillary features in favor of benign entities have high specificity for benignity.

431
Plasma 6
Longitudinal Characterization of Liver Regeneration and Portal Hemodynamics in Living Donor Liver Transplant
Alejandro Roldán-Alzate1,2,3, David R Rutkowski2, Luis A Fernandez4, and Scott B Reeder1,3,5,6

1Radiology, University of Wisconsin, Madison, WI, United States, 2Mechanical Engineering, University of Wisconsin, Madison, WI, United States, 3Biomedical Engineering, University of Wisconsin, Madison, WI, United States, 4Surgery, University of Wisconsin, Madison, WI, United States, 5Medical Physics, University of Wisconsin, Madison, United States, 6Medicine, University of Wisconsin, Madison, United States

The purpose of this study was to evaluate longitudinal liver regeneration and hemodynamic changes of living donor liver transplant (LDLT) donors in response to surgical liver resection. Five living related liver donors were studied. Subjects were imaged using 4D Flow MRI before and at several times following partial hepatectomy. The ability to longitudinally evaluate liver regeneration and portal hemodynamic changes non-invasively demonstrates that 4D flow MRI is a suitable tool for both surgical planning of LDLT, and for improved understanding of the liver regeneration and hemodynamic changes that occur in the remnant liver of the donor.

432
Plasma 7
4D flow MRI of Liver Hemodynamics: Influence of Velocity Encoding, Different Field Strength and Contrast Application on Visualization and Quantification of blood flow
Zoran Stankovic1, Bernd Jung1, Alan Arthur Peters1, Jelena Surla2, Edouard Semaan2, Michael Ith1, Johannes Heverhagen1, Michael Markl2, and Jeremy D. Collins2

1DIPR, Inselspital, University Hospital Bern, University of Bern, Bern, Switzerland, 2Radiology, Northwestern University, Chicago, IL, United States

4D flow MRI offers the possibility for complete volumetric and functional assessment of liver blood flow in patients with liver cirrhosis. This study reveals a significant difference when using a lower venc for visualization of the portal vein branches. Similar results are obtained for contrast application and different field strengths. For qualitative assessment of the intrahepatic branches by 4D flow MRI a lower venc is recommended.

433
Plasma 8
Quantitative Free-Breathing Dynamic Contrast-enhanced MRI in Hepatocellular Carcinoma Using Gd-EOB-DTPA:Correlations With Ki67 Proliferation Status and Histological Grades
Jie Chen1, Chenyang Chen1, Chunchao Xia2, and Bin Song2

1West China Medical School of Sichuan University, Chengdu, People's Republic of China, 2Departmento of Radiology, West China Hospital of Sichuan University, Chengdu, People's Republic of China

This study aims to validate a free-breathing DCE-MRI in HCC patients using gadoxetic acid, and to determine the relationship between DCE-MRI parameters and histological results. Perfusion parameters (Ktrans, Kep, Ve and iAUC) from 34 patients were compared with CT results and correlated with Ki67 indices and the histological grades of HCC. Significant relationship was found between DCE-MRI and CT results, indicating the validity of this protocol in evaluating the vascular change of HCC. The DCE-MRI derived Ktrans and iAUC were significantly correlated with the histological grades of HCC, suggesting the potential of those parameters in predicting the malignancy of tumors. 

434
Plasma 9
The value of high resolution gadoextic acid-enhanced MR cholangiography for evaluating biliary anatomy of living liver donor: comparison with T2 weighted (T2W) MR cholangiography and conventional gadoxetic acid enhanced MR cholangiography
Hyo-Jin Kang1, Jeong Min Lee1, Jeong Hee Yoon1, Won Chang1, Ijin Joo1, and Joon Koo Han1

1Radiology, Seoul National University Hospital, Seoul, Korea, Republic of

The addition of gadoxetic acid-enhanced sFOV T1W-MRC to T2W-MRC is able to provide more precise depiction of biliary anatomy, which is crucial for the prevention of post-operative biliary complications of living liver donors.

435
Plasma 10
Water-Only Look-Locker Inversion recovery (WOLLI) T1 mapping
Liam D. Garrison1, Christina Levick1,2, Michael Pavlides1,2, Tom Marjot3, Ferenc Mozes1, Leanne Hodson3, Stefan Neubauer1, Matthew Robson1, and Christopher T. Rodgers1

1OCMR, RDM Cardiovascular Medicine, University of Oxford, Oxford, United Kingdom, 2Translational Gastroenterology Unit, Nuffield Department of Medicine, University of Oxford, Oxford, United Kingdom, 3Oxford Centre for Diabetes, Endocrinology and Metabolism (OCDEM), Radcliffe Department of Medicine, University of Oxford, United Kingdom

We propose a new “Water-Only Look-Locker Inversion recovery” (WOLLI) sequence, based on MOLLI, that enables water-selective T1-mapping in an 8hb breath-hold at 3T. WOLLI uses a hypergeometric (HG) inversion pulse to selectively invert water with negligible effect on fat. To separate the steady-state fat and water signals, WOLLI adds one or more fat-inversions starting from the plateau of the water T1* recovery. WOLLI uses an extended Deichmann-Haase formula to correct for readout-induced saturation. We validated this approach by simulations, scans in a phantom containing 19 fat/water mixtures, and liver scans in 12 subjects (volunteers and liver disease patients).

436
Plasma 11
Region-of-interest size of hepatic 2D MR elastography decreases with increasing R2* for gradient-echo but not spin-echo techniques
Cheng William Hong1, Adrija Mamidipalli1, Ethan Z Sy1, Jonathan C Hooker1, Calvin Andrew Tran1, Tanya Wolfson2, Soudabeh Fazeli Dehkordy1, Scott B Reeder3, Rohit Loomba4, and Claude B Sirlin1

1Liver Imaging Group, Department of Radiology, University of California, San Diego, San Diego, CA, United States, 2Computational and Applied Statistics Laboratory, University of California, San Diego, San Diego, CA, United States, 3Departments of Radiology, Medical Physics, Biomedical Engineering, Medicine, and Emergency Medicine, University of Wisconsin, Madison, Madison, WI, United States, 4NAFLD Research Center, Division of Gastroenterology, Department of Medicine, University of California, San Diego, San Diego, CA, United States

MR elastography (MRE) is an emerging technique for the non-invasive assessment of hepatic stiffness and fibrosis, and can be based on gradient-echo (GRE) or spin-echo (SE) acquisition. This study demonstrates that 2D-SE provides significantly larger reliable-wave-quality regions-of-interest (ROIs) than 2D-GRE at 3T. Additionally, 2D-GRE ROI sizes are negatively correlated with hepatic R2*, while 2D-SE ROI sizes are not associated with R2*. This suggests that 2D-SE may be the preferred MRE sequence at 3T and in patients with known iron overload.

437
Plasma 12
Estimating Liver Function in Chronic Liver Disease Patients Using DCE-MRI and Whole-Body Pharmacokinetic Modeling
Markus Karlsson1,2, Mikael F Forsgren1,2, Olof Dahlqvist-Leinhard1,2, Nils Dahlström1,2, Bengt Norén2, Mattias Ekstedt1, Stergios Kechagias1, Gunnar Cedersund3, and Peter Lundberg1,2

1Department of Health and Medicine, Linköping University, Linköping, Sweden, 2Center for Medical Image Science and Visualisation, Linköping University, Linköping, Sweden, 3Department of Biomedical Engineering, Linköping University, Linköping, Sweden

Dynamic contrast enhanced MRI with Gd-EOB-DTPA is a promising method for investigating liver function. However, many of the proposed procedures relies on such a high temporal resolution, and low spatial resolution, that the images are rendered unsuitable for radiographic reading. Here we have tested and validated a recently developed procedure using a whole-body pharmacokinetic model in a cohort of patients with chronic liver disease. Moreover we also show that the approach can separate advanced from mild fibrosis.

438
Plasma 13
Prognostic Role of Liver Stiffness Measurement Using Magnetic Resonance Elastography in Patients with Compensated Chronic Liver Disease
Dong Ho Lee1 and Jeong Min Lee2

1Radiology, Seoul National University Hospital, Seoul, Korea, Republic of, 2Korea, Republic of

Liver stiffness measurement (LSM) using magnetic resonance elastography (MRE) can estimate the degree of liver fibrosis. We retrospectively evaluate the prognostic role of LSM using MRE in compensated chronic liver disease patients. A total of 217 patients with compensated chronic liver disease who underwent MRE were included. After a mean and median follow-up of 44.5±17.8 months and 46.0 months, LSM value obtained from MRE was turned out to be significant predictive factor for overall survival, development of hepatic decompensation and occurrence of hepatocellular carcinoma. 

439
Plasma 14
Epidemiology and spatial heterogeneity of hepatic fat and iron deposition: an MRI-based analysis
Daniel R Ludwig1, Tyler J Fraum1, Scott Kilian2, and Kathryn J Fowler1

1Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, MO, United States, 2Southern Illinois University School of Medicine

MRI has emerged as a reliable, noninvasive means of liver fat and iron quantification. We retrospectively studied 1006 patients that underwent standard-of-care liver MRI at a single tertiary care center. Multivariate analysis was used to identify factors predictive of the severity and spatial heterogeneity of hepatic fat deposition (HFD) and hepatic iron deposition (HID). Greater spatial heterogeneity of HFD and HID generally occurred as the severity of HFD and HID increased, suggesting higher risk for misclassification by biopsy with more advanced disease. Overall, by globally evaluating the liver, MRI constitutes a robust tool for assessing hepatic fat and iron deposition.

440
Plasma 15
Free breathing T2* mapping of the Liver using a compressed sensing reconstruction
Paul de Heer1, Oliver J Gurney-Champion1, Jurgen H. Runge1,2, Remy Klaassen3, Jasper Schoormans1, Bram F. Coolen4, Hanneke W.M. van Laarhoven3, Gustav J. Strijkers4, Jaap Stoker1, and Aart J. Nederveen1

1Radiology, AMC, Amsterdam, Netherlands, 2Division of Imaging Sciences and Biomedical Engineering, King’s College London, London, United Kingdom, 3Medical Oncology, AMC, Amsterdam, Netherlands, 4Biomedical Engineering & Physics, AMC, Amsterdam, Netherlands

Hemochromatosis (iron overload) occurs in a range of liver diseaes.(1,2) Iron content can be measured invasively with liver biopsy but is commonly replaced by non-invasive MR measurements, including T2* mapping. This is commonly done in a breath-hold to reduce the effects of respiratory motion. In this work we show that a stack of stars radial golden angle T2* mapping multi echo sequence during free breathing in combination with CS reconstruction facilitates high resolution imaging in the liver. This approach bears promise beyond liver imaging for visualizing smaller organs and pathologies, e.g. the pancreas and lymph nodes.


Electronic Power Pitch Poster

Poster: Reconstruction Highlights

Exhibition Hall Tuesday 14:45 - 15:45

441
Plasma 16
Joint Reconstruction of Phase-Cycled Balanced SSFP with Constrained Parallel Imaging
Berkin Bilgic1, Thomas Witzel1, Himanshu Bhat2, Lawrence L Wald1, and Kawin Setsompop1

1Martinos Center for Biomedical Imaging, Charlestown, MA, United States, 2Siemens Medical Solutions, Charlestown, MA, United States

 Balanced SSFP is an SNR-efficient sequence with unique T2/T1 contrast, but suffers from banding artifacts due to B0 sensitivity. These artifacts can be mitigated through RF phase-cycling at a cost of significant increase in scan time. Here, we propose Joint L1-SPIRiT to jointly reconstruct highly accelerated/undersampled phase-cycled images and convert the different banding artifacts of these images into additional spatial encoding. This enables highly accelerated 2D and Simultaneous Multi-Slice imaging, thus mitigating scan time burden of phase-cycled bSSFP while producing banding-free images. In particular, Joint L1-SPIRiT provides around 2-fold decrease in both the average g-factor and RMSE relative to GRAPPA.


442
Plasma 17
Wave-CAIPI for Highly Accelerated MP-RAGE Imaging
Daniel Polak1,2, Kawin Setsompop1,3,4, Stephen F. Cauley1,3, Borjan A. Gagoski3,5, Himanshu Batt6, Florian Maier2, Lawrence L. Wald1,3,4, and Berkin Bilgic1,3

1Massachusetts General Hospital, Boston, MA, United States, 2German Cancer Resarch Center, Heidelberg, Germany, 3Harvard Medical School, Boston, MA, United States, 4Harvard-MIT Health Sciences and Technology, Boston, MA, United States, 5Boston Children’s Hospital, Boston, MA, United States, 6Siemens Medical Solutions Inc, Malvern, PA, United States

We introduce a highly accelerated T1-weighted MP-RAGE acquisition that utilizes a novel reordering scheme and Wave-CAIPI encoding to retain high image quality. R=9-fold accelerated in vivo MP-RAGE scans were performed in 71 sec, with maximum and average g-factor of gmax=1.27 and gavg=1.06. Compared to the state-of-the-art 2D-CAIPIRINHA method, this is a factor of 4.6/1.4 improvement in gmax/gavg. In addition, we demonstrate a 57 sec acquisition at 7T with R=12-fold acceleration. This acquisition had a g-factor performance of gmax=1.15 and gavg=1.04. Wave encoding overcomes the g-factor noise amplification penalty and allows for an order of magnitude acceleration of MP-RAGE acquisitions. 

443
Plasma 18
Differential Domain Analysis for 3D Cartesian Sampling
Evan Levine1,2 and Brian Hargreaves2

1Electrical Engineering, Stanford University, Stanford, CA, United States, 2Radiology, Stanford University, Stanford, CA, United States

Selection of arbitrary 3D Cartesian sampling patterns for support-contrained MRI, parallel MRI, and dynamic MRI can be heuristical, and g-factor calculations require a computationally expensive simulation. To provide theoretical guidance and a method to optimize 3D Cartesian sampling, a novel concept of a differential distribution is introduced to represent a distribution of pairwise differences between sample locations, and is related to point-spread-functions. Its relationship to noise amplification in a generalized sensitivity encoding model and linear reconstruction is then used to efficiently optimize multidimensional k-space sampling. Examples in support-constrained MRI, parallel MRI, and dynamic MRI demonstrate reduced noise amplification

444
Plasma 19
Comparison of 2D and 3D MR Liver Elastography in 600 Patients
Bogdan Dzyubak1, Kevin J. Glaser1, Sudhakar K. Venkatesh1, and Richard L. Ehman1

1Radiology, Mayo Clinic, Rochester, MN, United States

2D Magnetic Resonance Elastography (MRE) is a validated method for staging liver fibrosis via liver stiffness measurements produced by introducing and imaging acoustic waves. Newer 3D MRE additionally images waves propagating out-of-plane. This retrospective study compared 2D and 3D liver MRE stiffness measurements across 600 patient exams. The two methods had excellent agreement, with 3D MRE yielding 6% lower stiffness and having lower failure rate. 3D MRE, which has the same acquisition time, is a good alternative for liver imaging as it does not suffer from out-of-plane propagation bias and has the added potential to characterize smaller abdominal organs.

445
Plasma 20
Calibrationless Parallel Imaging Reconstruction Using Hankel Tensor Completion (HTC)
Yilong Liu1,2, Jun Cao1,2, Mengye Lyu1,2, and Ed X. Wu1,2

1Laboratory of Biomedical Imaging and Signal Processing, The University of Hong Kong, Hong Kong, People's Republic of China, 2Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong, People's Republic of China

Autocalibrating parallel imaging requires sufficient autocalibration signals (ACS) for reliable estimation of coil sensitivity. However, this is not feasible in some applications, for example, spectroscopic imaging where matrix size is relatively small. Recent publications (SAKE, P-LORAKS, and ALOHA, etc.) proposed to construct k-space data into block-wise Hankel matrix, and perform parallel imaging reconstruction with low rank matrix completion. In this study, we proposed to construct a block-wise Hankel tensor, and use tensor completion techniques to synthesize the unacquired samples. This method can also be extended to reconstruct multiple slices simultaneously and provide more accurate reconstruction.

446
Plasma 21
Highly Accelerated Magnetic Resonance Elastography via Bayesian Modeling
Christopher Ebersole1,2, Rizwan Ahmad1, Adam Rich1, Lee C. Potter1, and Arunark Kolipaka2

1Electrical and Computer Engineering, The Ohio State University, Columbus, OH, United States, 2Radiology, The Ohio State University Wexner Medical Center, Columbus, OH, United States

While magnetic resonance elastography (MRE) provides a non-invasive method of estimating tissue stiffness, which is indicative of a variety of diseases, MRE scans typically require lengthy breath-holds which are prohibitive for many patients. We have extended a recently proposed Bayesian imaging method, called ReVEAL, for MRE. This method is capable of reconstructing images from highly undersampled data by leveraging both sparsity and the near equal magnitude across multiple offsets, inherent to MRE acquisition, as reconstruction constraints. This reconstruction method is validated against SENSE using a retrospectively downsampled phantom dataset and three retrospectively downsampled in vivo liver datasets.

447
Plasma 22
RACE-GRASP: Respiratory-weighted and Aortic Contrast Enhancement-guided GRASP MRI
Li Feng1, Krishna Shanbhogue1, Daniel K Sodickson1, Hersh Chandarana1, and Ricardo Otazo1

1Center for Advanced Imaging Innovation and Research (CAI2R), New York University School of Medicine, New York, NY, United States

This work proposes a technique named RACE-GRASP (Respiratory-weighted and Aortic Contrast Enhancement guided Golden-angle RAdial Sparse Parallel imaging) for robust free-breathing DCE-MRI of the liver. First, the aortic contrast enhancement curve is automatically detected from continuously acquired data and is used to guide k-space sorting to ensure precise capture of desired contrast-enhancement phases. Second, k-space data of each contrast phase are binned into different respiratory motion states, and each motion bin is weighted differently during image reconstruction to reduce motion blurring. The performance of RACE-GRASP was demonstrated in 5 healthy volunteers and was compared with conventional GRASP. 

448
Plasma 23
Real-time 3D cardiac MRI using through-time radial GRAPPA and GPU-enabled reconstruction pipelines in the Gadgetron framework
Dominique Franson1, James Ahad2, Jesse Hamilton1, Wei-Ching Lo1, Yun Jiang1, Yong Chen3, and Nicole Seiberlich1,3

1Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States, 2School of Medicine, Case Western Reserve University, Cleveland, OH, 3Radiology, University Hospitals, Cleveland, OH

An accelerated 3D cardiac dataset (8 partitions; in-plane spatial resolution: 2.34 x 2.34 mm2; partition thickness = 8 mm) can be reconstructed using through-time radial GRAPPA and GPU-enabled pipelines in the Gadgetron framework in approximately 515.5 ms. This work may enable real-time, 3D imaging in the heart with on-line reconstruction. 

449
Plasma 24
Navigator-free EPI ghost correction using low-rank matrix modeling: Theoretical insights and practical improvements
Rodrigo A. Lobos1, Tae Hyung Kim1, W. Scott Hoge2,3, and Justin P. Haldar1

1Electrical Engineering, University of Southern California, Los Angeles, CA, United States, 2Radiology, Brigham and Women’s Hospital, Boston, MA, United States, 3Radiology, Harvard Medical School, Boston, MA, United States

While the formation of ghost-free images from EPI data can be a difficult problem, recent low-rank matrix modeling methods have demonstrated promising results.  In this abstract, we provide new theoretical insight into these approaches, and show that the low-rank ghost correction optimization problem has infinitely many solutions without using additional constraints.  However, we also show that SENSE-like or GRAPPA-like constraints can be successfully used to make the problem well-posed, even for single-channel data.  Additionally, we show that substantial performance gains can be achieved over previous low-rank ghost correction implementations by using nonconvex low-rank regularization instead of previous convex approaches.

450
Plasma 25
Non-ECG First-Pass Myocardial Perfusion T1 Mapping with Low-Rank Tensor Cardiovascular MR Multitasking
Anthony G. Christodoulou1,2, Jaime L. Shaw1,3, Xiaoming Bi4, Behzad Sharif1,5, and Debiao Li1,3

1Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States, 2Cedars-Sinai Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States, 3Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, United States, 4Siemens Healthcare, Los Angeles, CA, United States, 5Department of Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, CA, United States

Quantitative first-pass myocardial perfusion imaging is a potentially powerful tool for diagnosing coronary artery disease. However, quantification is complicated by ECG misfires and the nonlinear response of signal intensity to contrast agent concentration. Here we propose a method overcoming the curse of dimensionality to simultaneously image cardiac motion, contrast dynamics, and T1 relaxation in 2D and 3D, using a low-rank tensor imaging framework for cardiovascular MR multitasking. This non-ECG, first-pass myocardial perfusion T1 mapping method accounts for the signal intensity nonlinearity, allowing direct quantification of contrast agent concentration at any cardiac phase in any cardiac cycle.

451
Plasma 26
T1-T2 Shuffling: Multi-Contrast 3D Fast Spin-Echo with T1 and T2 Sensitivity
Jonathan I Tamir1, Valentina Taviani2, Shreyas S Vasanawala3, and Michael Lustig1

1Electrical Engineering and Computer Sciences, University of California, Berkeley, Berkeley, CA, United States, 2MR Applications and Workflow, GE Healthcare, Menlo Park, CA, United States, 3Radiology, Stanford University, CA, United States

Volumetric fast spin-echo (3DFSE) imaging is clinically desirable because of its robustness to off-resonance and its utility for obtaining many types of image contrasts at isotropic resolution. However, its routine clinical use is inhibited by blurring due to long echo trains needed to maintain scan efficiency. Her we present T1-T2 Shuffling, a 3DFSE-based acquisition and reconstruction scheme that mitigates image blur and retrospectively synthesize T1-weighted and T2-weighted image contrasts. The acquisition, an extension of T2 Shuffling, employs a randomizing echo train view ordering with variable repetition times (TRs). The use of short TRs increases scan efficiency while providing T1 sensitivity.

452
Plasma 27
Simultaneous T1/T2 measurements in combination with PCA-SENSE reconstruction (T1* shuffling) and multicomponent analysis
Julian Pfister1, Martin Blaimer1, Peter M. Jakob2, and Felix A. Breuer1

1Magnetic Resonance and X-ray Imaging, Fraunhofer Development Center X-ray Technology (EZRT), Würzburg, Germany, 2Experimental Physics 5, University of Würzburg, Würzburg, Germany

An inversion recovery TrueFISP sequence with a golden angle based radial readout in combination with a view sharing KWIC filter reconstruction is able to produce quantitative M0, T1 and T2 maps within a single shot. However the KWIC filter leads to temporal blurring especially at high spatial frequencies. Here, we propose an alternative reconstruction method based on the principle component analysis (PCA) for providing an improved temporal fidelity. Furthermore this approach is extended for a multicomponent analysis by an inverse Laplace transform. Results from brain measurements demonstrate that this technique can identify different tissue types within a single voxel.

453
Plasma 28
Accelerated 3D Multispectral MRI with Robust Principal Component Analysis for Separation of On and Off-resonance Signals
Evan Levine1,2, Kathryn Stevens2, and Brian Hargreaves2

1Electrical Engineering, Stanford University, Stanford, CA, United States, 2Radiology, Stanford University, Stanford, CA, United States

3D multispectral imaging (MSI) corrects most distortion in MRI near metallic implants at the cost of prolonged scan time by phase encoding to resolve slice distortions. However, existing methods to accelerate 3D MSI do not exploit the redundancy of slice-phase encoding for the dominant on-resonance signal. A novel compact representation of 3D-MSI images based on a decomposition of on- and off-resonance via robust principal component analysis (RPCA) is introduced to exploit this redundancy in a calibration and model-free reconstruction and push the current limits of accelerated 3D MSI. A complementary randomized sampling strategy is used to vary undersampling in different spectral bins to enable the separation. Experiments with retrospective and prospective undersampling show comparable image quality between standard MSI images and 2.6-3.4-fold accelerated RPCA and improvement over bin-by-bin compressed sensing reconstruction.

454
Plasma 29
Field Map Combination Method for Multiple-Acquisition bSSFP
Anjali Datta1 and Dwight G Nishimura1

1Electrical Engineering, Stanford University, Stanford, CA, United States

FIESTA-C/CISS enables the reconstruction of banding-free bSSFP images, but residual ripple remains in the combined images.  Also, in the heart, flow near a stop-band may cause a component image to include significant contributions from out-of-slice spins; this hyper-intense signal persists in images combined using conventional methods.  Here, we use a B0 map to combine FIESTA-C/CISS cardiac cine images.  Knowledge of B0 enables us to only include pass-band signal in the final image and exclude stop- and bright-bands.  In phantom and in vivo studies, the proposed method had less ripple and greatly reduced flow artifacts compared to maximum-intensity projection and root-sum-of-squares.

455
Plasma 30
Stochastic Primal-Dual Optimization for Locally Low-Rank MRI Reconstruction: A Stable Alternative to Cycle Spinning
Joshua D. Trzasko1

1Radiology, Mayo Clinic, Rochester, MN, United States

Locally low rank (LLR) reconstruction is an effective strategy that has found application across a range of MRI applications.  In lieu of processing all overlapping image blocks each iteration, most LLR implementations employ “cycle spinning”, where only a random subset of blocks is processed.  Cycle spinning improves efficiency, but may compromise reconstruction convergence and introduce artifacts.  We propose a primal-dual algorithm for LLR reconstruction and show that stochastically updating the dual variable provides similar computational advantage as cycle spinning but avoids its primary disadvantages.  Reconstruction performance benefits are demonstrated on both a numerical phantom and in vivo.  


Electronic Power Pitch Poster

Poster: Best of Cardiovascular MR: Myocardial Tissue Characterization

Exhibition Hall Tuesday 17:15 - 18:15

540
Plasma 1
Three-dimensional holographic visualization of high-resolution myocardial scar on HoloLens
Jihye Jang1,2, Gifty Addae1, Warren Manning1,3, and Reza Nezafat1

1Department of Medicine, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, United States, 2Department of Computer Science, Technical University of Munich, Munich, Germany, 3Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, United States

We present a framework for 3D holographic visualization of high-resolution 3D late gadolinium enhancement (LGE) of myocardial scar on augmented-reality glass HoloLens via two approaches; 1) voxel-wise 3D scar rendering and 2) surface projection of the scar. Holographic visualization of high-resolution 3D LGE data will provide a true 3D perception of the complex scar architecture with an immersive experience to explore the clinical standard LGE images in a more interactive and interpretable way, which may facilitate MR-guided scar-related ventricular tachycardia ablation.

541
Plasma 2
Inducibility of ventricular arrhythmia correlates with the indices of myocardial viability using manganese enhanced MRI (MEMRI) in a porcine ischemia reperfusion model
Atsushi Tachibana1,2,3, Junaid Zaman1, Yuko Tada1, Michelle R. Santoso1, and Phillip C. Yang1

1Cardiovascular Medicine, Stanford University, Stanford, CA, United States, 2Radiology, AIC Yaesu Clinic, Tokyo, Japan, 3Graduate School of Human Health Sciences, Tokyo Metropolitan University, Tokyo, Japan

Peri-infarct region (PIR), containing the viable but injured myocardium, has been related to the occurrence of ventricular arrhythmia. Reliable in vivo detection of arrhythmogenic region presents significant challenge. While delayed enhanced MRI (DEMRI) with gadolinium (Gd) detects the myocardial infarction, the non-specific property does not detect the viable but injured cardiomyocytes in the PIR. Manganese (Mn) enters the live cells via L-type calcium channel, and enables dual enhancement technique to identify the overlapping viable region in PIR. We measured the correlation between the volume of the PIR and inducibility of ventricular arrhythmia using porcine ischemia reperfusion model.

542
Plasma 3
In Vivo Hyperpolarized MRS Study Showing Improved Cardiac Metabolism in Type 1 Diabetes with Daily L-Carnitine Treatment.
Dragana Savic1, Kerstin N. Timm, Vicky Ball, Lisa Heather, and Damian J. Tyler

1University of Oxford, Oxford, United Kingdom

Carnitine acts as a buffer of acetyl-CoA units in the mitochondria, as well as facilitating transport of fatty acids, and carnitine levels are decreased in the diabetic heart. The purpose of this study was to investigate the effect of L-Carnitine supplementation on cardiac function and metabolism in the diabetic rat heart. We show that daily injections of L-Carnitine can alter cardiac metabolism in the in vivo diabetic rat heart, and can increase flux through pyruvate dehydrogenase. Such studies will allow a better understanding of the interactions between metabolism and function in the diabetic heart and may provide new insight into novel therapeutics.

543
Plasma 4
Integrated T2 preparation and Inversion Recovery pulse (T2IR) for combined myocardium T1 and T2 mapping
Rui Guo1, Zhensen Chen1, Jianwen Luo1, and Haiyan Ding1

1Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, People's Republic of China

In this study we designed a novel hybrid T1 and T2 magnetization preparation pulse (T2IR) and implement a combined T1 and T2 mapping sequence based on MOLLI scheme. Phantom experiments showed that the proposed sequence has high consistency with reference methods for both T1 (R2= 0.99) and T2 (R2=0.97) measurements. In vivo results showed that high quality T1 and T2 maps of myocardium could be obtained by the proposed sequence.


544
Plasma 5
Non-contrast assessment of vasodilator response using native myocardial T1 and T2 mapping and Arterial Spin Labeled CMR
Nilesh R Ghugre1,2,3, Hung P Do4, Kenneth Chu3, Venkat Ramanan1, Krishna S Nayak5, and Graham A Wright1,2,3

1Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON, Canada, 2Schulich Heart Program, Sunnybrook Research Institute, Toronto, ON, Canada, 3Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada, 4Department of Physics and Astronomy, University of Southern California, Los Angeles, CA, United States, 5Ming Hsieh Department of Electrical Engineering, University of Southern California, Los Angeles, CA, United States

Myocardial vasodilator response is an important indicator of microvascular function and integrity in ischemic injury. The objective of our study was to systematically compare myocardial stress response with native contrast mechanisms involving quantitative T2, T1 and Arterial spin labeled (ASL) imaging. Our findings suggest that oxygenation (T2 BOLD effect), blood volume (T1 effect) and perfusion (ASL) taken together could offer a complementary contrast-free framework to identify vasodilator dysfunction in heart disease. These could potentially offer insights into the myocardial remodeling process particularly in the remote territory, which develops hypertrophy and fibrosis in the high-risk patients in the chronic stage.

545
Plasma 6
Dictionary-based Reconstruction for Free-Breathing Myocardial T1 Mapping
Jinkyu Kang1,2, Jihye Jang1, Vahid Tarokh2, and Reza Nezafat1

1Department of Medicine, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, United States, 2School of Engineering and Applied Science, Havard University, Cambridge, MA, United States

In this study, we propose a novel reconstruction framework for myocardial T1 mapping based on a dictionary-based reconstruction algorithm that simultaneously reduces scan time while compensating for respiratory and cardiac-induced motions between different T1-weighted images of T1 mapping sequence.

546
Plasma 7
Validation of Cardiac Diffusion Tensor MRI using Transparent Tissue Preparation (CLARITY) with 3D Optical Microscopy
Christopher Nguyen1, Sang-Eun Lee2, Jongjin Yoon3, Hyuk-Jae Chang2, Sekeun Kim2, Chul Hoon Kim3, and Debiao Li1,4

1Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States, 2Division of Cardiology, Yonsei University College of Medicine, Seoul, Korea, Republic of, 3Departement of Pharmacology, Yonsei University College of Medicine, Seoul, Korea, Republic of, 4Bioengineering, University of California Los Angeles, Los Angeles, CA, United States

The myocardium consists of a complex 3-dimensional (3D) microstructure has been shown to be perturbed in the presence of myocardial ischemia. Recently, diffusion tensor magnetic resonance imaging (DT-CMR) was introduced which can characterize the 3D tissue microstructure in intact myocardium. However, past histologic validation of DTI has been limited since traditional pathology allows only 2D optical microscopy after potentially destructive tissue sectioning. We present a novel approach to validate the derivation of the myocardial fiber orientation (MFO) using DT-CMR with 3D histology using a non-destructive, transparent-tissue preparation technique (CLARITY). Results indicate MFO derived from 3D histology and DT-CMR are strongly concordant.

547
Plasma 8
Free-breathing Black-blood Prepared Cardiac Diffusion Tensor Imaging
Constantin von Deuster1, Georg Spinner1, Robbert van Gorkum 1, Christian T. Stoeck1, and Sebastian Kozerke1

1Institute for Biomedical Engineering, ETH and University Zurich, Zurich, Switzerland

In vivo cardiac Diffusion Tensor Imaging (DTI) can be influenced by myocardial perfusion. To address this limitation, reference images with moderate diffusion weighting can be employed, which, however, reduce diffusion contrast and require the acquisition of three orthogonal diffusion encoding directions. In this work, blood suppression was implemented using black blood preparation to reduce contribution of perfusion to the diffusion weighted signal. This allows for the use of a marginally weighted reference image resulting in a reduction in scan time by about 17% with improved or comparable accuracy of diffusion metrics relative to previous methods.  

548
Plasma 9
First-Pass Nitroxide-Enhanced MRI for Imaging Myocardial Perfusion without Gadolinium
Sophia Xinyuan Cui1 and Frederick H. Epstein1,2

1Biomedical Engineering, University of Virginia, Charlottesville, VA, United States, 2Radiology, University of Virginia, Charlottesville, VA, United States

First-pass MRI using gadolinium-based contrast agents is widely used to image myocardial perfusion. However, gadolinium is contraindicated for patients with severely impaired renal function (a substantial portion of heart disease patients), and methods that do not employ gadolinium are needed. Nitroxide stable free radicals are non-metallic compounds with an unpaired electron and, correspondingly, are paramagnetic and T1-shortening. We investigated first-pass nitroxide-enhanced perfusion MRI of the heart as an alternative to first-pass gadolinium-enhanced MRI.  Five C57Bl/6 mice underwent first-pass imaging with the nitroxide agent 3CP and the results showed that nitroxide-enhanced MRI can quantify regional myocardial blood flow, as the average myocardial perfusion was 7.0±1.3 ml/g/min, a value in the normal range for mice. 

549
Plasma 10
Cardiac fMRI - A Novel Approach for Reliably Detecting Myocardial Oxygenation Changes with Precise Modulation of Arterial CO2
Hsin-Jung yang1, Ilkay Oksuz2, Michael Klein3, Olivia Sobczyk3, Damini Dey1, Jane Sykes4, John Butler4, Xiaoming Bi5, Behzad Sharif1, Ivan Cokic1, Debiao Li1, Piotr Slomka1, Frank S Prato4, Joseph Fisher3, Sotirios Tsaftaris2, and Rohan Dharmakumar1

1Cedars Sinai Medical Center, Los Angeles, CA, United States, 2IMT School for Advanced Studies Lucca, 3University of Toronto, 4Lawson Health Research Institute, 5Siemens Healthcare

Although cardiac BOLD MRI can detect ischemic heart disease without ionizing radiation and contrast agents, its reliability remains poor due to the low sensitivity and specificity. We propose a novel strategy to overcome these barriers through: (i) an improved MRI strategy with free gas-exchange capability; (ii) repeat stimulation of heart using a validated prospective arterial CO2 targeting technique; and (iii) a statistical framework to increase the confidence measure of BOLD signal changes.  Our results show that the proposed approach  can be used to significantly increase the confidence in detecting myocardial BOLD response in conditions of health and disease. 

550
Plasma 11
High-fat diet feeding in mice may partially protect the heart from pressure overload induced heart failure - a longitudinal study of cardiac metabolism and function
Emmy Manders1, Desiree Abdurrachim1, Miranda Nabben2, Klaas Nicolay1, and Jeanine J Prompers1,3

1Department of Biomedical Engineering, Biomedical NMR, Eindhoven University of Technology, Eindhoven, Netherlands, 2Department of Genetics and Cell Biology, CARIM school for cardiovascular diseases, Maastricht University, Netherlands, 3Department of Radiology, University Medical Center, Utrecht, Netherlands

Obesity increases the risk of heart failure, but obese heart failure patients have a better prognosis and survival. Altered cardiac energy metabolism is proposed to be an important contributor to this discrepancy. With an in vivo longitudinal approach measuring cardiac function (MRI), energetics (31P-MRS) and lipid content (1H-MRS) during the development of heart failure we have shown that cardiac function was less impaired in obese mice compared with lean mice after induction of pressure overload. This suggests that metabolic adaptations in obese mice are not detrimental and may even be beneficial in heart failure development.

551
Plasma 12
Cardiac Magnetic Resonance Elastography for Quantitative Assessment of Elevated Myocardial Stiffness in Cardiac Amyloidosis
Arvin Arani1, Shivaram P. Arunachalam1, Ian CY Chang2, Francis Baffour1, Kevin J Glaser1, Joshua D Trzasko1, Kiaran McGee1, Armando Manduca1, Martha Grogan2, Angela Dispenzieri3,4, Richard L Ehman1, and Philip A Araoz1

1Radiology, Mayo Clinic, Rochester, MN, United States, 2Cardiovascular Diseases, Mayo Clinic, Rochester, MN, United States, 3Medicine: Division of Hematology, Mayo Clinic, Rochester, MN, United States, 4Laboratory Medicine and Pathology, Mayo Clinic

Myocardial stiffness plays an important role in cardiac function. The objective of this study is to evaluate if 3D high frequency cardiac MR elastography (MRE) can measure increased myocardial stiffness in cardiac amyloidosis patients compared to healthy volunteers. Twenty-two patients with cardiac amyloidosis and 16 healthy volunteers were enrolled. The myocardial stiffness of cardiac amyloid patients (median: 11.4 kPa, min: 9.2, max: 15.7) was found to be significantly stiffer (p < 0.01) than healthy controls (median: 8.2 kPa, min: 7.2, max: 11.8). These results motivate future investigation of 3D high frequency cardiac MRE in different patient cohorts.

552
Plasma 13
Ungated myocardial perfusion imaging with complete left ventricular coverage using radial simultaneous multi-slice imaging
Ganesh Adluru1, Jason Mendes1, Ye Tian1, Brent Wilson2, and Edward DiBella1

1Radiology and Imaging Sciences, University of Utah, Salt lake city, UT, United States, 2Cardiology, University of Utah, Salt lake city, UT, United States

Myocardial perfusion imaging is a promising tool to determine the downstream effects of blocked coronary arteries.  Ungated perfusion imaging is a promising alternative to conventional ECG-gated acquisitions.  Existing ungated methods can acquire only 4-5 short-axis slices often with large slice gaps.  Continuous and complete coverage is desired in order to avoid missed regions of perfusion deficit.  Here we use an undersampled radial simultaneous multi-slice (SMS) acquisition to obtain complete coverage of the left ventricle.  We use a block matching constrained reconstruction that is robust to inter-time frame cardiac and respiratory motion.  We obtain 12 short axis slices in ~250 msec.

553
Plasma 14
As Easy as Echo: Interactive Fetal Cardiac MR Imaging
Davide Piccini1,2,3, Jérôme Yerly2,4, Jérôme Chaptinel2, Milan Prsa5, Yvan Mivelaz5, Leonor Alamo2, Yvan Vial6, Gregoire Berchier2, Chantal Rohner2, Peter Speier7, Tobias Kober1,2,3, and Matthias Stuber2,4

1Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland, 2Department of Radiology, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland, 3LTS5, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland, 4Center for Biomedical Imaging (CIBM), Lausanne, Switzerland, 5Department of Pediatrics, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland, 6Department of Gynecology-Obstetrics, University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland, 7Magnetic Resonance, Siemens Healthcare GmbH, Erlangen, Germany

Although fetal echocardiography remains the gold standard for prenatal detection of congenital heart disease, mainly due to its ease-of-use, availability, and high diagnostic performance, MRI is occasionally used as a complementary and safe modality. However, MRI workflow is problematic as bulk fetal motion can occur anytime during acquisition, but can only be identified retrospectively, after image reconstruction. We describe an acquisition scheme that changes this workflow and allows interactive real-time planning of the fetal cardiac scan. The operator can easily find the desired scan plane even in a moving imaging target. This technique is applied and tested in two pregnant patients.

554
Plasma 15
Low Rank Compressed Sensing Reconstruction for More Precise Cardiac MRF Measurements
Jesse Ian Hamilton1, Yun Jiang1, Dan Ma2, Yong Chen2, Shivani Pawha2, Wei-Ching Lo1, Joshua Batesole2, Mark Griswold1,2, and Nicole Seiberlich1

1Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States, 2Radiology, University Hospitals, Cleveland, OH, United States

A low rank compressed sensing and parallel imaging reconstruction termed Sparse MRF is introduced to improve the precision of mapping myocardial T1 and T2 with MR Fingerprinting. Sparse MRF enforces data consistency while also constraining the temporal signal evolutions using a low dimensional subspace derived from the SVD of the dictionary along time. Different reconstruction parameters are investigated in simulations with a cardiac phantom. Results from phantom and in vivo cardiac scans indicate that Sparse MRF yields approximately the same mean T1 and T2 measurements as other MRF matching techniques but with smaller standard deviations.  


Electronic Power Pitch Poster

Poster: New Molecular & Metabolic Imaging Approaches

Exhibition Hall Tuesday 17:15 - 18:15

555
Plasma 16
Dynamic Hyperpolarized 13C Metabolic Imaging of Patients with Brain Tumors
Ilwoo Park1, Peder EZ Larson1, Jeremy Gordon1, Lucas Carvajal1, Hsin-Yu Chen1, Mark VanCriekinge1, Robert Bok1, Jason C Crane1, Adam Elkhaled1, Joanna Phillips2, James B Slater1, Marcus Ferrone3, John Kurhanewicz1, Dan Vigneron1, Susan Chang2, and Sarah J Nelson1

1Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, United States, 2Neurological Surgery, University of California San Francisco, San Francisco, CA, United States, 3Department of Clinical Pharmacy, University of California San Francisco, San Francisco, CA, United States

Dynamic 13C data were acquired following injection of hyperpolarized [1-13C]pyruvate from 3 patients previously diagnosed with glioblastoma. Pyruvate, lactate and bicarbonate signal with high SNR were detected in human brain. Lactate/Pyruvate appeared to be relatively high in the contra-lateral, normal appearing brain. In contrast, tumor regions produced higher Lactate/Bicarbonate than contra-lateral brain. The contrast-enhancing lesion of one patient, who underwent surgical resection shortly after 13C imaging due to suspected recurrence, produced a relatively low level of Lactate/Pyruvate compared to contra-lateral brain and Lactate/Bicarbonate similar to the value in contra-lateral brain. Subsequent biopsy of the contrast-enhancing lesion indicated treatment effect.

556
Plasma 17
Hyperpolarized 13C MRS of the Human Heart
Albert P. Chen1, Justin Y.C. Lau2,3, Benjamin J. Geraghty2,3, William J. Perks4, Idan Roifman5, Graham A. Wright2,3,5, Kim A. Connelly6, and Charles H. Cunningham2,3

1GE Healthcare, Toronto, ON, Canada, 2Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada, 3Medical Biophysics, University of Toronto, Toronto, ON, Canada, 4Pharmacy, Sunnybrook Health Sciences Centre, Toronto, ON, Canada, 5Schulich Heart Program, Sunnybrook Health Sciences Centre, Toronto, ON, Canada, 6Cardiology, St. Michael’s Hospital, Toronto, ON, Canada

The feasibility of acquiring hyperpolarized 13C images from human hearts following injections of HP [1-13C]pyruvate solution has been recently demonstrated.  Following the rapid multi-slice 13C imaging acquisition, 13C spectroscopic data were acquired from the whole heart to detect any residual hyperpolarized magnetization.  13C pyruvate, lactate, alanine and bicarbonate were observed in all 5 subjects.  13CO2 was also detected in two of the datasets.  Good inter-subject consistency in the observed metabolite ratios from these spectra demonstrated the potential for changes in cardiac metabolism due to disease to be interrogated with simple whole-heart spectroscopy.     

557
Plasma 18
In vivo metabolic imaging of neuroinflammation following traumatic brain injury using hyperpolarized [1-13C] pyruvate
Caroline Guglielmetti1,2, Austin Chou1,2, Karen Krukowski1,2, Maria Serena Paladini1,2, Lara-Kirstie Riparip1,2, Susanna Rosi1,2,3, and Myriam Chaumeil2,4

1Brain and Spinal Injury Center, University of California San Francisco, San Francisco, CA, United States, 2Department of Physical Therapy and Rehabilitation Science, University of California San Francisco, San Francisco, CA, United States, 3Department of Neurological Surgery, University of California San Francisco, San Francisco, CA, United States, 4Surbeck Laboratory of Advanced Imaging, Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, United States

This study demonstrates that metabolic imaging of hyperpolarized [1-13C] pyruvate can detect increased hyperpolarized lactate production in vivo in a preclinical model of Traumatic Brain Injury. Correlative assays further demonstrate that this increased lactate is linked to the presence of pro-inflammatory macrophages that upregulate pyruvate dehydrogenase kinase 1, subsequently leading to regional pyruvate dehydrogenase inhibition. Metabolic imaging of hyperpolarized [1-13C] pyruvate thus has great potential to provide a novel tool for in vivo detection of neuroinflammation.

558
Plasma 19
Toward Dynamic 3D Cardiac Perfusion Imaging Using bSSFP and Hyperpolarized tert-Butanol
Timothy Pagliaro1, Gopal Varma1, Li Zhao1, David C Alsop1, and Aaron K Grant1

1Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, United States

Perfusion imaging is a promising application for hyperpolarized tracers, as they provide high signal with no endogenous background.  Hyperpolarized 13C labeled tert-butanol is a perfusion agent with long T1 and T2 relaxation times in vivo. Moreover, because it diffuses freely through tissue, bolus injections of tert-butanol are largely extracted from the vasculature on a first pass, and the residence time in tissue is on the order of tens of seconds.  This provides a long time frame for dynamic imaging.  Here we demonstrate the feasibility of time-resolved 3D cardiac perfusion imaging in rats.

559
Plasma 20
Detection of Bacteria-specific metabolism using hyperpolarized 13C pyruvate
Renuka Sriram1, Jinny Sun1, Javier Villanueva-Meyer1, Justin DesLos Santos1, Christopher Mutch1, Oren Rosenberg2, Mark Van Criekinge1, John Kurhanewicz1, David Wilson1, and Michael Ohliger1

1Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, United States, 2Department of Infectious Diseases, University of California San Francisco, San Francisco, CA, United States

Bacterial infection is a major health problem, with high morbidity and mortality. Current imaging techniques have limited ability to differentiate infection from either tumor or sterile inflammation, and invasive tissue sampling is frequently required. There is currently no clinically-available non-invasive method to directly detect living bacteria in vivo. We describe a method for detecting bacteria specific metabolism using hyperpolarized 13C pyruvic acid.

560
Plasma 21
In vivo pH imaging using hyperpolarized 13C-labelled zymonic acid
Stephan Duewel1,2,3, Christian Hundshammer1,2, Malte Gersch4, Benedikt Feuerecker1, Axel Haase3, Steffen J Glaser2, Markus Schwaiger1, and Franz Schilling1

1Department of Nuclear Medicine, Technical University of Munich, Munich, Germany, 2Department of Chemistry, Technical University of Munich, Garching, Germany, 3Institute of Medical Engineering, Technical University of Munich, Garching, Germany, 4Medical Research Council Laboratory of Molecular Biology, Cambridge, United Kingdom

Pathologies which overrule natural pH regulatory mechanisms such as ischemia, inflammation or tumors can trigger local pH changes in the human body. Currently, clinical routine measurement of extracellular pH is limited to measuring systemic blood pH. We synthesized, characterized, calibrated and applied [1,5-13C2]zymonic acid (ZA) as a novel hyperpolarized 13C pH biosensor. With its demonstrated features both in vitro and in vivo (bladder, healthy kidney, Mat B III adenocarcinoma), we believe that ZA could help localize and quantify regions with aberrant acid-base balance, allowing for improved understanding, diagnostics and therapy of common diseases. 

561
Plasma 22
A new method for measuring T$$$_{1\rho}$$$ of hyperpolarized radioactive isotopes using gamma rays
Yuan Zheng1,2, Gordon D. Cates1, William A. Tobias1, and G. Wilson Miller3

1Department of Physics, University of Virginia, Charlottesville, VA, United States, 2UIH America, Houston, TX, United States, 3Radiology and Medical Imaging, University of Virginia, Charlottesville, VA, United States

We have developed a novel technique that combines MR and gamma detection for measuring T of radioactive isotopes. Gamma-ray emission is anisotropic with respect to the polarization direction of hyperpolarized radioactive nuclei (spin>1/2). When the spins are flipped into the transverse plane and subjected to a spin-locking field, the emission anisotropy also precesses and gamma detectors in the transverse plane will observe an oscillating count rate. Decay of the oscillation amplitude during SL can be used to fit T. This technique also vastly reduces the number of spins needed for a meaningful measurement since gamma-ray detection is highly efficient.

562
Plasma 23
Occupational Manganese Exposure: Reversibility of Increased GABA Levels and Brain Mn Accumulation
David A. Edmondson1, Ruoyun Ma1, Chien-Lin Yeh1, S. Elizabeth Zauber2, Sandy Snyder1, Eric Ward1, and Ulrike Dydak1

1School of Health Sciences, Purdue University, West Lafayette, IN, United States, 2Department of Neurology, Indiana University School of Medicine, Indianapolis, IN, United States

While manganese (Mn) is known in the pre-clinical community as a T1 contrast agent, it is also notorious as a neurotoxin that can cause irreversible parkinsonian symptoms at high enough exposure levels. In an occupational setting, workers are exposed to Mn through processes such as welding, smelting, and other metalwork. As the workload changes over time, so does the level of exposure. Using MRI and MRS, effects of exposure such as elevated thalamic GABA levels and brain Mn deposition can be detected and show evidence of reversibility. This may help identifying meaningful no-observed-adverse-effect levels (NOAEL) as used in occupational settings.

563
Plasma 24
CM101: an optimized MR probe targeting type I collagen for detection of liver fibrosis
Christian T. Farrar1, Richard Kennan2, Eric Gale1, Ian Ramsay1,3, Ricard Masia4, Gunisha Arora5, Kailyn Looby5, Lan Wei5, Michelle Bunzel2, Chunlian Zhang2, Yonghua Zhu2, Taro Akiyama2, Michael Klimas2, Shirly Pinto2, Himashinie Diyabalanage3, Valerie Humblet3, Bryan C. Fuchs5, and Peter Caravan1

1Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, United States, 2Merck Research Laboratories, Kenilworth, NJ, United States, 3Collagen Medical, Belmont, MA, United States, 4Pathology, Massachusetts General Hospital, Boston, MA, 5Surgical Oncology, Massachusetts General Hospital, Boston, MA, United States

Recent molecular MR approaches targeting collagen demonstrated the promise of noninvasive detection and staging of liver fibrosis and monitoring treatment response, but the molecular probe used was not suitable for clinical translation due to the low stability of the Gd chelator chosen. CM-101 is a new peptide based probe using the highly stable Gd-DOTA chelate that is rapidly eliminated from plasma intact into the urine and shows no sign of Gd accumulation.  CM-101 robustly detected liver fibrosis in a bile duct ligation model in rats and in a CCl4 mouse model. 

564
Plasma 25
A High Throughput, MEMRI-Based Imaging Pipeline to Study Mouse Models of Sporadic Human Cancer
Harikrishna Rallapalli1,2, I-Li Tan3, Alexandre Wojcinski3, Alexandra L Joyner3, and Daniel H Turnbull1,2

1Kimmel Center for Biology and Medicine at the Skirball Institute of Biomolecular Medicine, New York University School of Medicine, New York, NY, United States, 2Biomedical Imaging Graduate Program and Department of Radiology, New York University School of Medicine, New York, NY, United States, 3Developmental Biology, Sloan Kettering Institute, New York, NY, United States

A high-throughput imaging pipeline is presented to quantify the heterogeneity in longitudinal disease progression in mouse models of human brain cancer and to test the efficacy of novel anti-cancer therapeutics in accurate mouse models of sporadic human cancer.

565
Plasma 26
In vivo quantification of IONP-labeled PAR T-cells using positive contrast MRI
Jinjin Zhang1, Sidath C Kumarapperuma2, Qi Shao3, Lakmal Kotelawala2, John C Bischof3, Carston R Wagner2, and Michael Garwood1

1Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, United States, 2Department of Medicinal Chemistry, University of Minnesota, Minneapolis, MN, United States, 3Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN, United States

Immunotherapies have received increasing attention as novel therapeutics for the treatment of cancer and autoimmune disease. In this study, IONP labeled PAR T-cells were tracked and quantified in vivo using the SWIFT sequence for positive contrast imaging and T1 mapping. The longitudinal relaxation rate constant (R1) showed a linear dependence on the cell density in vitro and thus was used to quantify T cell density in vivo in liver. These preliminary results demonstrate how positive contrast from an ultra-short T2 sensitive sequence can provide a tool to quantify the bio-distribution of T cells.

566
Plasma 27
A Unique ´Cargo Internalization Receptor (CIR)´ System for In Vivo Tracking of Individual Cell Populations by 19F MRI
Pascal Bouvain1, Paul Baran2, Tuba Güden-Silber1, Sebastian Temme1, Jens Moll2, Doreen Floss2, Christoph Grapentin3, Jürgen Scheller2, and Ulrich Flögel1

1Molecular Cardiology, Heinrich-Heine University, Düsseldorf, Germany, 2Biochemistry and Molecular Biology II, Heinrich-Heine University, Germany, 3Pharmaceutical Technology and Biopharmacy, Albert-Ludwigs-University

Synopsis: We demonstrate the capability of unique ‘cargo internalization receptors’ (CIR) for specific cell tracking. A nanobody for green fluorescent protein (GFP) was used to engineer surface receptors which undergo rapid internalization after GFP binding. For 19F MR visibility, the GFP carrier was equipped with perfluorocarbon (PFC) contrast cargo. PFC cargo uptake after CIR transfection was verified by flow cytometry, confocal microscopy, and 1H/19F MRI. The results show that this approach can be successfully used for targeted contrast agent internalization, which can be extended to an cell-specific CIR expression in transgenic mice for in vivo cell tracking by 19F MRI.

567
Plasma 28
Characterization of Gd-DOTA-APC, a novel cancer-targeting MRI contrast agent
Christina Brunnquell1, Ray Zhang2, Benjamin Cox1,3, Anatoly Pinchuk2, Alan McMillan2, and Jamey Weichert2

1Medical Physics, University of Wisconsin-Madison, Madison, WI, United States, 2Radiology, University of Wisconsin-Madison, Madison, WI, United States, 3Medical Engineering Group, Morgridge Institute for Research, Madison, WI, United States

In this work we characterize the relaxivity, chemical stability, and tumor-specific uptake of a cancer-targeting T1-shortening contrast agent, Gd-DOTA-APC. We observe striking longitudinal relaxivity of up to 16.5 s-1/mM and 10.6 s-1/mM at 1.5T and 3.0T, respectively. High chemical stability was measured, with less than 0.1% free Gd3+ detected after dissolution of the agent in buffer. Finally, we observe tumor-specific T1-weighted signal enhancement following Gd-DOTA-APC delivery, sustained out to seven days after administration. These observations indicate that Gd-DOTA-APC holds potential as a safe and effective agent for targeted cancer imaging.

568
Plasma 29
CMRO2 Quantification in Human Brain with Direct 17O-MRI: Profile Likelihood Analysis for Optimization of Temporal Resolution
Dmitry Kurzhunov1, Robert Borowiak1,2,3, Ali Caglar Özen1, and Michael Bock1

1Dept. of Radiology, Medical Physics, Medical Center – University of Freiburg, Freiburg, Germany, 2German Cancer Consortium (DKTK), Heidelberg, Germany, 3German Cancer Research Center (DKFZ), Heidelberg, Germany

In this study the temporal resolution of 17O-MRI protocols for quantification of the cerebral metabolic rate of oxygen consumption (CMRO2) in human brain were optimized using the profile likelihood (PL) method. For this, retrospective analysis of the influence of temporal resolution on the CMRO2 values and their PL-based confidence intervals (CI) was performed. Dynamic 17O-MRI was implemented with a 3D golden-angle radial acquisition during and after inhalation of 17O gas. The results showed that 17O-MRI data acquired at a temporal resolution 120≤Δt≤165 seconds gave identifiable CMRO2 values of 0.82‑1.18/0.92‑1.42 µmol/gtissue/min in WM/GM brain regions. 

569
Plasma 30
Region-Specific Effects of AMP-Activated Protein Kinase on the Neurochemical Profiles of the Hippocampus and Midbrain in Mice
Ivan Tkac1, Biplab Dasgupta2, and Raghavendra Rao3

1Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, United States, 2Division of Oncology, Cincinnatio Children’s Hospital Medical Center, Cincinnati, OH, United States, 3Department of Pediatrics, Division of Neonatology, University of Minnesota, Minneapolis, MN, United States

Adenosine monophosphate-activated protein kinase (AMPK) is an evolutionarily conserved signaling molecule essential for cellular energy balance. AMPK senses metabolic stress and integrates diverse physiological signals to restore energy balance. Its role in the normal brain development is not well understood. The purpose of this study was to assess whether neurochemical profiles of developing mouse brain are affected by knocking out of AMPK enzyme in a region-specific manner. Observed changes in metabolite levels (Lac, Glu) indicate reduced energy metabolism in AMPK knockout mice relative to WT controls. In addition, changes in myo-Ins suggest osmotic stress.


Electronic Power Pitch Poster

Poster: Marching on Musculoskeletal

Exhibition Hall Wednesday 9:15 - 10:15

645
Plasma 1
Accelerated knee imaging using a deep learning based reconstruction
Florian Knoll1,2, Kerstin Hammernik3, Elisabeth Garwood1,2, Anna Hirschmann4, Leon Rybak1,2, Mary Bruno1,2, Tobias Block1,2, James Babb1,2, Thomas Pock3,5, Daniel K Sodickson1,2, and Michael P Recht1,2

1Radiology, NYU, New York, NY, United States, 2CAI2R, NYU, New York, NY, United States, 3Institute of Computer Graphics and Vision, Graz University of Technology, Graz, Austria, 4Radiology, University Hospital Basel, Basel, Switzerland, 5Austria Safety & Security Department, AIT Austrian Institute of Technology GmbH, Vienna, Austria

The goal of this study is to determine the diagnostic accuracy and image quality of a recently proposed deep learning based image reconstruction for accelerated MR examination of the knee. 25 prospectively accelerated cases were evaluated by three readers and show excellent concordance to the current clinical gold standard in identification of internal derangement.

646
Plasma 2
Anterior Tibial Translation Following ACL Reconstruction is Associated with Postsurgical Cartilage Matrix Changes.
Alan K Li1, Valentina Pedoia 2, Keiko Amano2, Jonathan Ochoa2, Qi Li 2, Benjamin Ma2, and Xiaojuan Li2

1University of California, Berkeley, Berkeley, CA, United States, 2University of California, San Francisco, San Francisco, CA, United States

Biomechanical abnormalities and accelerated cartilage matrix changes are commonly seen following ACL injury; however, the association between the two remains unclear. The purpose of this study was to analyze the relationship between altered joint kinematics and long term cartilage health. Utilizing voxel based relaxometry with T1p and T2 mapping sequences, in conjuction with MRI kinematics of the tibia and femur bone, allowed for the assessment of local cartilage matrix changes 2 years following ACL reconstruction. Notably, anterior translation of the tibia in the injured knee was associated with greater cartilage degeneration in the medial femoral and tibial cartilage.

647
Plasma 3
Longitudinal characterization of deformation-induced skeletal muscle damage by T2-mapping, DWI and MRE
Jules L. Nelissen1,2, Willeke A. Traa3, Larry de Graaf1, Cees W. J. Oomens3, Jurgen H. Runge4,5, Ralph Sinkus4, Klaas Nicolay1, Aart J. Nederveen5, Martijn Froeling6, and Gustav J. Strijkers2

1Biomedical NMR, Eindhoven University of Technology, Eindhoven, Netherlands, 2Preclinical and Translational MRI, Academic Medical Center, Amsterdam, Netherlands, 3Biomechanics of Soft Tissues, Eindhoven University of Technology, Eindhoven, Netherlands, 4Division of Imaging Sciences & Biomedical Engineering, King's College London, London, United Kingdom, 5Radiology, Academic Medical Center, Amsterdam, Netherlands, 6Department of Radiology, University Medical Center Utrecht, Utrecht, Netherlands

Skeletal muscle injury is often accompanied by fibrosis, fatty infiltration, and edema. There is great need for imaging readouts to detect and quantify such compositional changes, which would aid understanding and greatly assist in the development of emerging therapies. The goal of this work was to use a multi-modality approach, combining magnetic resonance elastography (MRE; muscle stiffness, fibrosis) with diffusion-weighted imaging (DWI; myocyte integrity) and T2-mapping (edema, inflammation) to provide a comprehensive assessment of muscle injury development and regeneration. The multi-modality assessment provided differential readouts of the deformation-induced muscle injury development and regeneration process. 

648
Plasma 4
Age Related Differences in Shear Strain in Medial Gastrocnemius: Implications for Lateral Transmission of Force
Vadim Malis1, Usha Sinha2, Robert Csapo3, and Shantanu Sinha3

1Physics, UC San Diego, San Diego, CA, United States, 2Physics, San Diego State University, San Diego, CA, United States, 3Radiology, UC San Diego, San Diego, CA, United States

The disproportionate loss of muscle force in comparison to loss of muscle mass with age remains unexplained.  Recent studies indicate that the remodeling of the extracellular matrix (ECM) may disrupt lateral force transmission pathways mediated by the ECM.  Shear strain is the mechanism that supports lateral transmission of force.  We quantified shear strain in muscle from the strain rate tensor derived from velocity encoded phase contrast dynamic images of the in-vivo human calf muscle under isometric contractions.  The maximal shear strain was significantly lower in the older cohort compared to the younger cohort which potentially identifies that lateral force transmission decreases with age.

649
Plasma 5
Metal Artifact Reduction MRI for the Assessment of the Rotational Alignment Knee Arthroplasty Implants: Compressed Sensing SEMAC TSE versus High-Bandwidth TSE
Filippo Del Grande1,2, Benjamin Fritz3, Satre Stuelke4, Steven E Stern5, Susanne Bensler3, and Jan Fritz1

1Radiology, The Johns Hopkins University School of Medicine, Baltimore, MD, United States, 2Radiology, Ospedale Regionale di Lugano, Lugano, Switzerland, 3Radiology, Orthopedic University Hospital Balgrist, Zurich, Switzerland, 4Radiology, The Johns Hopkins University School of Medicine, Baltimore, MD, 5Queensland University of Technology

Malrotation of knee arthroplasty implants is a source of pain following total knee arthroplasty and maybe measured on metal artifact reduction MR images; however, it is unclear which technique is best.   Therefore, we compared the reliability, repeatability, and precision of rotational alignment measurements that were obtained on optimized high-bandwidth and compressed sensing SEMAC TSE MR images and their relationships with symptoms. CS-SEMAC TSE MRI afforded the highest reliability, repeatability and precision of rotational alignment measurements, which correlate best with symptoms. CS-SEMAC TSE MRI may be preferred over high-BW TSE for rotational alignment measurements of knee arthroplasty implants.  

650
Plasma 6
Ability of MAVRIC MRI to Predict Component Loosening in Total Hip Arthroplasty
Alissa Jo Burge1, Gabrielle P Konin1, Jennifer Berkowitz1, Matthew Koff1, Douglas Padgett2, and Hollis Potter3

1Radiology and Imaging, Hospital for Special Surgery, New York, NY, United States, 2Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, United States, 3Hospital for Special Surgery, New York, NY, United States

Improved metal reduction techniques for conventional MRI pulse sequences and the addition of MAVRIC (multiacquisition variable resonance image combination) have been established as useful in assessing component osteolysis and synovial reactions. The purpose of this retrospective study was to determine the utility of MRI in assessing loosening of total hip arthroplasty in a cohort of patients using surgical confirmation of loosening as the gold standard. Our results show that loosening can be predicted with high sensitivity and specificity; however, intraoperative variability in assessing loosening and the overall low frequency of implant loosening are limiting factors.

651
Plasma 7
Simultaneous multi-slice TSE for clinical MR Imaging of lesions in the knee
Xiaona Li1, Zhigang Peng1, Yi Sun2, Panli Zuo2, Dingxin Wang3, and Jianling Cui1

1Radiology, the Third Hospital of Henbei Medical University, Shijiazhuang, People's Republic of China, 2MR Collaboration NE Asia, Siemens Healthcare, Shang Hai, People's Republic of China, 3Siemens Medical Solutions USA, Inc., Minneapolis, MN, United States

To introduce simultaneous multiple slices (SMS) turbo spin echo (TSE) and to evaluate its image quality and diagnostic accuracy for lesions in the knee. Participants were examined by SMS and routine TSE sequences. Both sequences were evaluated by three radiologists with subjective and objective scores in T1- and PD-weighted images. The diagnostic value in lesions was evaluated. SMS requires less scan time and offers similar imaging quality and diagnostic rate compared to routine TSE sequence. SMS is a valuable technique for MR examination of the knee.

652
Plasma 8
Simultaneous T2 Relaxometry and Morphometry of Cartilage and Meniscus with Double-Echo in Steady-State in Five Minutes
Akshay S Chaudhari1, Marianne S Black1, Bragi Sveinsson1, Garry E Gold1, and Brian A Hargreaves1

1Radiology, Stanford University, Stanford, CA, United States

Quantitative MRI parameters such as T2 relaxation times and morphometry are potential biomarkers for tracking spatial and temporal changes in musculoskeletal diseases and injuries. While cartilage has been widely studied, the short-T2 of meniscus makes it challenging to quantify in short scan times. In this study, we optimized the double-echo steady-state (DESS) pulse sequence to produce high-resolution and high signal-to-noise ratio images in five minutes. We compared the relaxometry and morphometry measures against established methods and found no significant differences. This suggests that a five-minute DESS scan could be used for simultaneous relaxometry and morphometry of the cartilage and meniscus. 

653
Plasma 9
Soft Tissue Tumors: Use of Intravoxel Incoherent Motion MR Imaging for Assessment of Diffusion and Perfusion for the Differentiation of Benign from Malignant Tumors
Haijun Wu1 and Changhong Liang1

1Department of Radiology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, People's Republic of China

The apparent diffusion coefficient (ADC) had better diagnostic performance than other Intravoxel incoherent motion (IVIM)-derived parameters did for differentiating malignancies from benign soft-tissue tumors. The f values of intermediate soft-tissue tumors are significantly lower than those of benign and malignant soft-tissue tumors. The combination of ADC and f values is significantly better than other IVIM parameters at differentiating soft-tissue tumors.

654
Plasma 10
1-year Follow-Up of T1ρ for Assessing Radiocarpal Cartilage Matrix Changes after Anti-TNF treatment for Rheumatoid Arthritis: Preliminary Results
Eric Ku1, Valentina Pedoia1, Matthew Tanaka1, Hyo Jin Choi1, Ursula Heilmeier1, Andrew Burghardt1, Jonathan Graf2, John Imboden2, Thomas Link1, and Xiaojuan Li1

1Department of Radiology and Biomedical Imaging, UCSF, San Francisco, CA, United States, 2Department of Medicine, UCSF, San Francisco, CA, United States

MR T is used to investigate biochemical changes in cartilage composition, but few studies have looked at its application in radiocarpal wrist cartilage. In this study, we assess 1-year changes in T following rheumatoid arthritis treatment and its relationship with changes in clinical disease activity scores and patient-reported outcomes. Changes between 1-year and baseline T values correlated significantly with disease activity score changes and approached significance with patient-reported outcome changes during the same period. Changes in T values at 3-months also correlated significantly with 1-year changes in metacarpophalangeal and wrist bone erosion volume measured with high-resolution peripheral quantitative CT (HR-pQCT).

655
Plasma 11
Simultaneous Multi-Slice Accelerated High Resolution MRI of the Knee: Comparison with In-plane Parallel Imaging Acceleration
Jan Fritz1, Benjamin Fritz2, Jialu Zhang3,4, Dharmdev H Joshi1, Gaurav K Thawait1, Li Pan5, and Dingxin Wang3,5

1The Johns Hopkins University School of Medicine, Baltimore, MD, United States, 2Orthopaedic University Hospital Balgrist, 3University of Minnesota, 4Zhejiang University, 5Siemens Healthcare USA

Simultaneous multi-slice acceleration techniques excite, acquire, and reconstruct multiple slices simultaneously and provide the potential to create substantially accelerated clinical TSE protocols with similar spatial and contrast resolution to current TSE protocols. We quantified the signal-to-noise and contrast-to-noise ratios of various combinations of parallel and simultaneous multi-slice acceleration and compared two 4-fold accelerated TSE protocols against a clinical 2-fold accelerated TSE standard. Our results demonstrate that 4-fold TSE acceleration enables 43-60% shorter acquisition times with similar image quality, structural visibility and observer satisfaction than standard parallel imaging acceleration. 

656
Plasma 12
New insights into the predilection sites of Juvenile Osteochondritis Dissecans using Quantitative Susceptibility Mapping
Jutta Ellermann1, Casey P Johnson2, Luning Wang3, Ferenc Toth4, Kevin Shea5, Cathy Carlson6, and Mikko J Nissi7,8

1Radiology, University of Minnesota, Minneapolis, MN, United States, 2Radiology, CMRR, University of Minnesota, 3University of Minnesota, 4College of Veterinary Medicine, University of Minnesota, 5St. Lukes Orthopaedics, Boise, ID, 6College of Veterinary Medicine, University of Minnesota, St. Paul, MN, 7Department of Applied Physics, University of Eastern Finland, 8Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland

The unique utilization of tissue-inherent MRI contrast using QSM for depicting the intraepiphyseal vascular supply provides high resolution and accuracy without using exogenous contrast making it a noninvasive tool for future in vivo studies. A better understanding of the development of the epiphyseal cartilage vascularity during skeletal maturation may shed light on the etiology of many developmental diseases, such as Juvenile Osteochondritis Dissecans that are precursors to osteoarthritis.

657
Plasma 13
Pile up correction for 3D-Multi Spectral Imaging using Gaussian Spectral Modeling and Bin Expansion
S Sivaram Kaushik1 and Kevin Koch2

1MR Applications and Workflow, GE Healthcare, Waukesha, WI, United States, 2Radiology, Medical College of Wisconsin, Milwaukee, WI, United States

The difficulty of imaging around metal implants has been overcome using pulse sequences such as MAVRIC SL and SEMAC. While the images are largely artifact-free, subtle intensity fluctuations, or ‘pile up’ artifacts still remain. The post-processing approach presented here uses information extracted from a spectral-domain model to identify and correct local fluctuations in image intensity. In these regions, the spectral bins are expanded using a moving average filter. When the expanded bins are combined, the pile up is significantly reduced. This pile up correction can improve the aesthetic quality of the images, and significantly improve their diagnostic ability.

658
Plasma 14
Correlation Time Mapping of Articular Cartilage: correlation with tissue composition and structure
Hassaan Elsayed1,2, Stefan Zbyn2, Mikko J Nissi3,4, Jari Rautiainen1,2,3,5, Matti Hanni1,2,5, and Miika T Nieminen1,2,5

1Medical Research Center, University of Oulu and Oulu University Hospital, Oulu, Finland, 2Research Unit of Medical Imaging, Physics and Technology, University of Oulu, Oulu, Finland, 3Department of Applied Physics, University of Eastern Finland, Kuopio, Finland, 4Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland, 5Department of Diagnostic Radiology, Oulu University Hospital, Oulu, Finland

Correlation time ($$$\tau_c$$$) is a physical property of the tissue that describes the dynamics of water molecules in their microenvironment. In this study, $$$\tau_c$$$ and T2 maps were obtained from enzymatically digested bovine samples. To evaluate the relationship between $$$\tau_c$$$and macromolecular components of cartilage, depth-wise $$$\tau_c$$$ profiles were correlated with quantitative histological measurements. The same comparison was performed for T2 data. Our results suggest that $$$\tau_c$$$ is sensitive to the laminar architecture of cartilage and to the proteoglycan content in the radial zone. $$$\tau_c$$$ provides complementary information to conventional T2 mapping.

659
Plasma 15
Correlation of 7T gagCEST MRI with Electromechanical and Biochemical Properties of Femoral Articular Cartilage
Sander Brinkhof1, Razmara Nizak2, Sotcheadt Sim3, Vitaliy Khlebnikov1, Dennis Klomp1, and Daniel Saris2,4

1Radiology, University Medical Center Utrecht, Utrecht, Netherlands, 2Orthopaedics, University Medical Center Utrecht, Utrecht, 3Biomomentum Inc., Laval, QC, Canada, 4MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, Netherlands

The purpose of this study was to validate the 7T 3D gagCEST measurements obtained in patients in vivo, using correlation of MRI GAG values with electromechanical mapping of the articular cartilage and biochemical analyses. Five patients were scanned before their total knee replacement, after which the extracted cartilage samples were used for electromechanical mapping and biochemical analyses. GAG content as determined by gagCEST MRI shows to be significantly correlated with biochemically measured GAG dry weight and with electromechanical mapping. This work shows that the electromechanical properties of cartilage are correlated with gagCEST MRI values. 


Electronic Power Pitch Poster

Poster: Cancer Imaging in the Body

Exhibition Hall Wednesday 9:15 - 10:15

660
Plasma 16
Interobserver Agreement and Diagnostic Performance of LI-RADS v2014 on contrast-enhanced MRI for non-HCC malignancies.
Natally de Souza Maciel Rocha Horvat1, Ines Nikolovski1, Niamh Long1, Scott Gerst1, Jian Zheng1, Linda Ma Pak1, Junting Zheng1, Lorenzo Mannelli1, and Richard Kinh Gian Do1

1Memorial Sloan Kettering Cancer Center, NY, NY, United States

Patients at risk for hepatocellular carcinoma (HCC) are often also at risk for intrahepatic cholangiocarcinoma (ICC) and combined hepatocellular cholangiocarcinoma (cHCC-ICC). The purpose of this study was to evaluate the sensitivity and specificity of MRI in 4 radiologists using LI-RADS v2014 and their inter-reader agreement for diagnosing non-HCC malignancies (ICC and cHCC-ICC). Applying LI-RADS v2014, we found sensitivities between 74% to 88% for the diagnosis of non-HCC malignancies with moderate to substantial interreader agreement for LI-RADS category as LR-M or non LR-M. However, lower sensitivity was seen for smaller tumors, which are known to overlap with HCC in imaging appearance.


661
Plasma 17
Quantification of hepatocellular carcinoma tumor heterogeneity with multiparametric MRI
Stefanie Hectors1, Mathilde Wagner1, Octavia Bane1, Cecilia Besa1, Sara Lewis2, Romain Remark3, Nelson Chen1, M. Isabel Fiel4, Hongfa Zhu4, Sacha Gnjatic5, Miriam Merad3, Yujin Hoshida6, and Bachir Taouli1

1Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, United States, 2Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, United States, 3Immunology Institute, Icahn School of Medicine at Mount Sinai, New York, NY, United States, 4Department of Pathology, Icahn School of Medicine at Mount Sinai, New York, NY, United States, 5Oncological Science, Icahn School of Medicine at Mount Sinai, New York, NY, United States, 6Department of Medicine/Division of Liver Diseases, Icahn School of Medicine at Mount Sinai, New York, NY, United States

We assessed tumor heterogeneity in hepatocellular carcinoma using multiparametric MRI (mpMRI) combining DWI, BOLD-MRI, TOLD-MRI and DCE-MRI measurements. Histogram characteristics (central tendency parameters mean and median and heterogeneity parameters standard deviation, kurtosis and skewness) of mpMRI data were quantified in the lesions and correlated between MRI methods and with histopathology and gene expression levels in a subset of patients. We observed that central tendency and heterogeneity parameters were largely complementary in terms of the assessed correlations. The proposed histogram analysis is therefore promising for noninvasive HCC characterization on the functional, immunohistochemical and genomics level. 

662
Plasma 18
3D MR Elastograpy in Prediction of Tumor Capsule Formation of Hepatocellular Carcinoma (HCC) in Patients with Hepatitis B Virus Infection
Jin Wang1, Hao Yang1, Yong Liu2, Jingbiao Chen1, Tianhui Zhang1, Kevin J. Glaser3, Xin Li4, Jun Chen3, Yao Zhang1, Qungang Shan1, Bingjun He1, Zhuang Kang1, Yin Meng3, Dzyubak Bogdan3, Venkatesh SK3, Ronghua Yan1, Xi Long1, and Richard L. Ehman3

1Department of Radiology, the Third Affiliated Hospital, Sun Yat-sen University (SYSU), Guangzhou, People's Republic of China, 2Department of Pathology, the Third Affiliated Hospital, Sun Yat-sen University (SYSU), Guangzhou, People's Republic of China, 3Department of Radiology, Mayo Clinic, Rochester, United States, 4GE Healthcare MR Research China, Guangzhou, People's Republic of China

Hepatocellular carcinoma (HCC) is one of the leading causes of cancer-related deaths around the world. Tumor capsule formation is a significant and independent predictor of survival and recurrence. We explored the potential value of HCC stiffness using 3D MR elastograpy for the prediction of tumor capsule formation. Results in 50 examinations showed that HCC stiffness has promise for the preoperative prediction of tumor capsule formation, thus providing motivation for further evaluation of HCC characteristics with MRE.

663
Plasma 19
Dynamic Contrast Enhanced MR Imaging of Hepatopancreatobiliary lesions in Combined use of Parallel Imaging and Compressed Sensing
Takayuki Masui1, Motoyuki Katayama1, Yuji Iwadate2, Naoyuki Takei2, Kang Wang3, Kevin King4, Kei Tsukamoto1, Mitsuteru Tsuchiya1, Yuki Hayashi1, Masako Sasaki1, Takahiro Yamada1, Kenichi Mizuki1, Harumi Sakahara5, Koji Yoneyama1, and Yuki Takayanagi1

1Radiology, Seirei Hamamatsu General Hospital, Hamamatsu, Japan, 2Global MR Applications and Workflow, GE Healthcare Japan, Hino, Japan, 3Global MR Applications and Workflow, GE Healthcare, Madison, WI, United States, 4Global MR Applications and Workflow, GE Healthcare, Waukesha, WI, United States, 5Radiology, Hamamatsu University School of Medicine, Hamamatsu, Japan

The feasibility of dynamic Gd-contrast study using turbo LAVA with ARC and CS for evaluation of pancreatobiliary lesions was evaluated. Acceptable image quality and good temporal resolutions with selective recognition of vasculatures, and lesion detections in the liver and pancreas could be made. With this technique, dynamic contrast imaging with high temporal and spatial resolutions can cover the wide area. It takes acceptable time for imaging reconstruction with ARC and CS at clinical 3T MR unit.

664
Plasma 20
Detection and measurement of neuroendocrine tumors liver metastases using Gd-EOB-DTPA enhanced MRI: comparison between multiple arterial phases, hepatobiliary phase, and DWI
Jia Xu1, Xuan Wang1, Hua dan Xue1, Shi tian Wang1, Hui Liu2, and Zheng yu Jin1

1Department of Radiology, Peking Union Medical College Hospital, Beijing, People's Republic of China, 2Siemens Ltd, Shanghai, People's Republic of China

The detection and evaluation of liver metastasis (LM) is important in initial staging and follow-up examinations of neuroendocrine tumors patients. Our aim is to compare different sequences including multiple arterial phases (MA), hepatobiliary phase (HA), diffusing-weighted imaging (DWI), and T2WI in Gd-EOB-DTPA-enhanced MRI, to find which sequence is better for detecting LM and which is better for size measurement. MA using CDT-VIBE were superior for the detection of small lesions. HBP imaging shows better repeatability in size measuring and may be a better choice for lesion size measurement during follow-up.

665
Plasma 21
Integrated slice-specific shimming (iShim) intravoxel incoherent motion diffusion-weighted MR imaging in the liver: the value of differential diagnosis between benign and malignant hepatic tumors
Hongxia Wang1, Qingbo Li2, Bin Wang3, Qinglei Shi4, Yan Feng1, Xingyue Jiang1, and Peigong Zhang3

1Radiology Department, Binzhou Medical University Hospital, Binzhou, People's Republic of China, 2Emergency Department, Binzhou People's Hospital, Binzhou, People's Republic of China, 3Binzhou Medical University, Yantai, People's Republic of China, 4MR Scientific NE Asia, Siemens Healthcare, Beijing, People's Republic of China

This study investigated the value of ADC value, D, Dstar, ADC500~800 acquired with prototype iShim sequence at 3T. All those parameters demonstrated high diagnostic capacity in distinguishing benign and malignant hepatic lesions and in distinguishing different types of malignant hepatic lesions,  among which ADC500~800 demonstrated the best diagnostic performance , which may have great value in clinical practice in future.

666
Plasma 22
Quantitative texture feature to predict Microscopic portal vein invasion of Hepatocellular carcinoma with contrast-enhanced MR images
Wu Zhou1, Qiyao Wang1, Su Yao2, Guangyi Wang3, Zaiyi Liu3, Changhong Liang3, and Lijuan Zhang1

1Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, People's Republic of China, 2Department of Pathology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, 3Department of Radiology, Guangdong General Hospital, Guangdong Academy of Medical Sciences

Portal vein invasion of Hepatocellular carcinoma (HCC) is a well-known prognostic factor for patients after hepatic resection or liver transplant. Typical risk factors of microscopic venous infiltration (MVI) include large tumor size, multifocality, poor histological grade and non-smooth tumor margins. In this work, we adopt a new techniue for quantitative texture feature Gray-level-run-length nonuniformity (GLRLN) to predict MVI of HCC based on the contrast-enhanced magnetic resonance images (CE-MRI). The present study showed that the proposed texture feature GLRLN in the portal vein phase of CE-MRI yielded best performance as compared with typical markers for the prediction of MVI.

667
Plasma 23
Conductivity of different malignancy grades of invasive ductal carcinomas and fibroadenomas
Ulrich Katscher1, Mussa Gagiyev1, Naoko Mori2, Keiko Tsuchiya3, Jochen Keupp1, and Hiroyuki Abe4

1Philips Research Europe, Hamburg, Germany, 2Tohoku University, Sendai, Japan, 3Shiga University, Hikone, Japan, 4University of Chicago, IL, United States

In ex vivo studies, breast tumors exhibit a significantly altered electric conductivity, measurable in vivo using “Electric Properties Tomography”. A significant conductivity difference was reported between benign and malignant breast tumors and between invasive and in situ carcinomas. This study tested a correlation between conductivity and WHO grade of invasive ductal carcinomas (IDCs) and benign fibroadenomas. A clear conductivity difference was found between IDC grade 1 and grade 2, as well as between IDC grade 1 and grade 3. No clear difference was found between fibroadenoma and IDC grade 1, as well as between IDC grade 2 and grade 3.

668
Plasma 24
A computer aided diagnosis (CAD) scoring tool: prostate cancer risk evaluation with PI-RADS v2 Guidelines
Lian Ding1, Ge Gao2, Yajing Zhang3, Chengyan Wang1, Jue Zhang1,4, Xiaoying Wang1,2, and Jing Fang1,4

1Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, People's Republic of China, 2Department of Radiology, Peking University Frist Hospital, Beijing, People's Republic of China, 3Philips Healthcare, Suzhou, China, Beijing, People's Republic of China, 4College of Engineering, Peking University, Beijing, People's Republic of China

The second version of the Prostate Imaging Reporting and Data System (PIRADSv2) indicates the likelihood of a clinically significant cancer with a simplified 5-point scale. To assist radiologists in making diagnostic decisions consistent with the PIRADSv2, we proposed a machine learning-based computer aided diagnosis (CAD) scoring tool of prostate cancer risk evaluation by combining apparent diffusion coefficient (ADC) and T2-weighted MRI-based features. The tool could provide a malignancy prediction color map of 5 scores. The statistical results of the total score test for 130 patients between radiologist graded and the CAD tool showed high accuracy and AUC.

669
Plasma 25
Deep learning to improve prostate cancer diagnosis
Nikolaos Dikaios1, Edward W Johnston2, Harbir S Sidhu2, Mrishta B Appaya2, Alex Freeman3, Hashim U Ahmed4, and Shonit Punwani2

1Electrical Engineering, University of Surrey, Guildford, United Kingdom, 2Centre for Medical Imaging, University College London, 3Histopathology, University College London, 4Surgery and Interventional Science, University College London

Multiparametric MRI (mp-MRI) can localize tumour within the prostate, guide biopsy, and assess disease burden. Nevertheless, mp-MRI itself remains imperfect. Almost 40% of mp-MRI studies are reported as indeterminate for significant cancer. An indeterminate mp-MRI confers no patient benefit, such patients require either repeat interval mp-MRI and/or subsequent biopsy. There remains a clear unmet need to improve diagnostic imaging over and above standard mp-MRI protocols. Previous work has developed zone specific logistic regression (LR) models for the determination of significant cancer  (any cancer-core-length (CCL) with Gleason>3+3 or any grade with CCL≥4 mm) in the peripheral (PZ) and the transition zone (TZ) based on quantitative mp-MRI parameters following MR imaging. This work proposes a state-of-art deep learning method to detect prostate cancer both in the PZ and the TZ. The proposed model is trained on a cohort of patients imaged at a 3T scanner, and validated on independent cohort of patients imaged at a 1.5T scanner. The performance of the model was compared with LR, Support Vector Machines and traditional Neural Networks.

670
Plasma 26
Comparing the Diagnostic Accuracy of Luminal Water Imaging with Diffusion-Weighted and Dynamic Contrast-Enhanced MRI for Evaluation of Prostate Cancer.
Shirin Sabouri1, Silvia D Chang2,3,4, Richard Savdie2, Edward C Jones5, S. Larry Goldenberg2,3, Peter C Black2,3, and Piotr Kozlowski2,3,4,6

1Department of Physics and Astronomy, University of British Columbia, Vancouver, BC, Canada, 2Department of Urologic Sciences, University of British Columbia, Vancouver, BC, Canada, 3Vancouver Prostate Centre, Vancouver, BC, Canada, 4Department of Radiology, University of British Columbia, Vancouver, BC, Canada, 5Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, BC, Canada, 6UBC MRI Research Center, Vancouver, BC, Canada

Luminal water imaging (LWI) is a newly developed MRI technique that has shown promising results for diagnosing and grading of prostate cancer. Incorporating LWI in clinical settings requires a profound investigation on its diagnostic accuracy by comparing it to existing clinical protocols. In this pilot study we have acquired and analyzed LWI, DWI, and DCE-MRI data from 15 patients to compare the diagnostic accuracy of LWI with the other two techniques. Our results show that LWI provides equal or higher accuracy in detection of tumors and better correlation with tumor grade compared to DWI and DCE-MRI.

671
Plasma 27
Novel Informatics Modeling of Magnetic Resonance Imaging Metrics for Characterizing Prostate Lesions with Pathology Correlation.
Katarzyna J. Macura1,2, Vishwa Parekh3, Seyed Saeid 4, and Michael A. Jacobs1,2

1The Russell H. Morgan Dept of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, United States, 2Sidney Kimmel Comprehensive Cancer Center, The Johns Hopkins University School of Medicine, Baltimore, MD, United States, 3Computer Science, The Johns Hopkins University, Baltimore, MD, United States, 4Dept of Radiology, University of Minnesota, Minneapolis, United States

Precision medicine is increasingly being used in radiological applications.  Advanced machine learning coupled with informatics modeling of clinical and radiological variables can provide the foundation to relate to precision medicine in patients with prostate cancer. We test our modeling using multiparametric prostate MR imaging (mpMRI) and MR-guided prostate biopsy with magnetic resonance-transrectal ultrasound (MR-TRUS) fusion to correlate the imaging features with histopathological results.

672
Plasma 28
Predictive Cytological Topography (PiCT): a Radiopathomics Approach to Mapping Prostate Cancer Cellularity
Amy Kaczmarowski1, Kenneth A Iczkowski2, Sarah L Hurrell1, Sean D McGarry1, Kenneth Jacobsohn3, William A Hall4, Mark Hohenwalter1, William See3, and Peter S LaViolette1

1Radiology, Medical College of Wisconsin, Milwaukee, WI, United States, 2Pathology, Medical College of Wisconsin, Milwaukee, WI, United States, 3Urology, Medical College of Wisconsin, Milwaukee, WI, United States, 4Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI, United States

This study combines radiographic images and pathological microscopy with machine learning to generate predictive maps of pathological features (i.e. new contrasts) based on segmented histological features. Predictive cytological topography (PiCT) maps of cellularity were utilized to detect additional pathologically confirmed high-grade prostate cancer tumors missed by radiologists.

673
Plasma 29
Estimating breast tumor blood flow and blood volume using MRI: DCE vs IVIM
Leonidas Georgiou1, Nisha Sharma2, Daniel Wilson3, and David L Buckley1

1Division of Biomedical Imaging, University of Leeds, Leeds, United Kingdom, 2Department of Radiology, Leeds Teaching Hospital NHS Trust, 3Department of Medical Physics and Engineering, Leeds Teaching Hospital NHS Trust

There is an increasing interest on whether IVIM parameters can be used as surrogates of perfusion and thus complement information on tumor microstructure. DCE-MRI techniques on the other hand have been widely used to characterise perfusion and hence offer the opportunity to test this hypothesis. In this study, we use high temporal resolution DCE-MRI and IVIM-DWI techniques to monitor patients with advanced breast cancer at various stages of their neoadjuvant chemotherapy, and assess the physiological relationship between perfusion and IVIM parameters.

674
Plasma 30
Discrimination of Malignant versus Benign Mediastinal Lymph Nodes Using Diffusion MRI with An IVIM Analysis
Li-Ping Qi1,2, Wan-Pu Yan3, Ke-Neng Chen3, Zheng Zhong2,4, Kejia Cai2,5, Xiao-Ting Li1, Ying-Shi Sun1, and Xiaohong Joe Zhou2,6

1Radiology, Peking University Cancer Hospital and Institute, Beijing, People's Republic of China, 2Center for MR Research, University of Illinois at Chicago, Chicago, IL, United States, 3Thoracic Surgery, Peking University Cancer Hospital and Institute, Beijing, People's Republic of China, 4Bioengineering, University of Illinois at Chicago, Chicago, IL, United States, 5Radiology and Bioengineering, University of Illinois at Chicago, Chicago, IL, United States, 6Radiology, Neurosurgery, and Bioengineering, University of Illinois at Chicago, Chicago, IL, United States

Noninvasive discrimination of mediastinal lymph nodes (MLN) is crucial for management of cancer patients such as those with non-small cell lung carcinoma. This study aims at investigating the value of IVIM diffusion parameters (D, D*, and f) as well as ADC for discrimination of malignant and benign MLN. A total of 91 MLN from 35 patients with histopathologic proven lesions were studied.  D and f of malignant mediastinal lymph nodes were significantly different from those in the benign ones. The combination of f and D produced the highest diagnostic performance as evaluated by a receiver operating characteristic (ROC) analysis.


Electronic Power Pitch Poster

Poster: RF Arrays & Systems

Exhibition Hall Wednesday 14:45 - 15:45

755
Plasma 1
Development and Clinical Implementation of Very Light Weight and Highly Flexible AIR Technology Arrays
Shreyas S Vasanawala1, Robert Stormont2, Scott Lindsay2, Thomas Grafendorfer2, Joseph Y Cheng1, John M Pauly3, Michael Lustig4, Greig Scott3, Jorge X Guzman2, Victor Taracila2, Daniel Chirayath2, and Fraser Robb2

1Radiology, Stanford University, Stanford, CA, United States, 2GE Healthcare, 3Electrical Engineering, Stanford University, 4Electrical Engineering and Computer Science, UC Berkeley

Pediatric body MRI faces challenges of widely varying patient sizes, heterogenous imaging indications, and limited patient cooperation. These difficulties are compounded by receiver array coils that are often mismatched to patients’ size.  In this work, we develop a novel light-weight flexible coil array that can be placed on a patient, and combined with a high-density posterior array and determine feasibility of clinical use in a pediatric setting.  The resulting coil is well received in the clinic and yields good image quality.

756
Plasma 2
The Optimality Principle for MR signal excitation and reception: new physical insights into ideal RF coil design
Daniel K. Sodickson1,2, Riccardo Lattanzi1,2, Manushka Vaidya1,2, Gang Chen1,2, Dmitry S. Novikov1,2, Christopher M. Collins1,2, and Graham C. Wiggins1,2

1Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging (CBI), Department of Radiology, New York University School of Medicine, New York, NY, United States, 2Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, NY, United States

Despite decades of collective experience, RF coil optimization has remained a largely empirical process, with clear insight into what might constitute truly task-optimal, as opposed to merely “good,” coil performance being difficult to come by.  We introduce a new principle, the Optimality Principle, which allows one to predict the form of signal-optimizing current patterns on any arbitrary surface, using a simple conceptual framework.  After a brief derivation of the principle, we illustrate its use in generating ideal current patterns for various experimental conditions, and in understanding the emergence of electric dipoles as strong performers at high frequency.

757
Plasma 3
Self-Decoupled RF Coils
Xinqiang Yan1,2, John C. Gore1,2,3, and William A. Grissom1,2,3

1Institute of Imaging Science, Vanderbilt University, Nashville, TN, United States, 2Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN, United States, 3Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, United States

RF arrays with large numbers of independent elements are desirable for parallel imaging and transmission. However, electromagnetic (EM) coupling between elements becomes significant as the number of coils increases and can severely impact coil performance. Several methods such as overlapping elements, L/C networks and auxiliary resonators have been proposed to reduce coupling, and are effective in decoupling adjacent elements, but are usually less effective for non-adjacent elements, and are not directly applicable to recently-proposed mixed arrays such as combinations of dipoles/monopoles and loop arrays. To address these problems, we propose a simple, geometry-independent self-decoupled RF coil design in which the two induced current modes in a loop coil can be adjusted to cancel each other. The method is validated in EM simulations, bench tests and MR experiments.

758
Plasma 4
Optically Controlled Four-Channel Transceiver for 7T imaging with RF Monitoring Feedback
Natalia Gudino1, Jacco A de Zwart1, Peter van Gelderen1, and Jeff H Duyn1

1Advanced MRI Section, LFMI,NINDS, National Institutes of Health, Bethesda, MD, United States

In multi-channel RF transmission, monitoring and accurate control of amplitude and phase of the transmit signal is necessary to ensure safety. To this end, we present a four-channel transceiver array for 7T imaging built from optically-controlled on-coil amplifiers with optical real-time RF signal monitoring. Based on this monitoring signal an amplitude and phase control can be implemented for flexible, accurate and rapid control of B1 and SAR.

759
Plasma 5
Double-Row 16-element Tight-Fit Transceiver Phased Array with High Transmit Performance for Whole Human Brain Imaging at 9.4T.
Nikolai I. Avdievich1, Ioannis A. Giapitzakis1, and Anke Henning1,2

1Max Planck Institute for Biological Cybernetics, Tübingen, Germany, 2Institute of Physics, Ernst-Moritz-Arndt University, Greifswald, Germany

  At ultra-high fields (UHF, >7T) a simple increase of the length of a single-row human head transmit (Tx) phased array cannot provide an adequate longitudinal coverage for the whole brain imaging. Multi-row (>2) arrays together with RF shimming have to be used instead. In this work, we constructed a 9.4T (400 MHz) 16-loop double-row transceiver array based on the analytical modeling. We demonstrated that simply by overlapping a very good decoupling can be obtained without additional decoupling strategies. This provides a recipe of a simple, robust, and very Tx-efficient design for parallel transmission and whole brain imaging at UHFs.   

760
Plasma 6
Compact iPRES coil assembly for Magnetic Resonance Fingerprinting
Michael Twieg1, Bhairav B Mehta2, Simone Coppo2, Haoqin Zhu3, Labros Petropoulos3, Hiroyuki Fujita3, and Mark A Griswold4

1Dept of Radiology, Case Western Reserve University, Cleveland Heights, OH, United States, 2Dept of Radiology, Case Western Reserve University, Cleveland, OH, United States, 3Quality Electrodynamics, Mayfield Village, OH, United States, 4Dept of Radiology, Case Western Reserve University, OH, United States

Magnetic Resonance Fingerprinting (MRF) makes use of spatially and temporally incoherent encoding schemes to produce orthogonal signals from different tissues. Here we present a coil optimized for MRF that integrates parallel receive, excitation, and shimming (iPRES) to provide an ideal method of modulating all three available magnetic fields (B1-, B1+, and ΔB0). In order to be useful in quantitative imaging, an iPRES array must convey these fields accurately, and cost effectively. Here we demonstrate an iPRES coil element with all three field amplifiers located on-coil, providing improved sensitivity and efficiency relative to remote amplifiers.

761
Plasma 7
Wireless coil based on meta-technologies for MRI implementations
Alena Shchelokova1, Alexey Slobozhanyuk1,2, Irina Melchakova1, Andrew Webb3, Yuri Kivshar1,2, and Pavel Belov1

1Department of Nanophotonics and Metamaterials, ITMO University, St.Petersburg, Russian Federation, 2Nonlinear Physics Center, Research School of Physics and Engineering, Australian National University, Canberra, Australia, 3Department of Radiology, Leiden University Medical Center, Leiden, Netherlands

We demonstrate experimentally how to improve the performance of MRI by employing wireless coil based on a hybrid tunable metasurface. We fabricate metasurface formed by an array of nonmagnetic metallic wires with high permittivity dielectric loads and investigate it in 1.5 T MRI machine. The metasurface enhances the SNR value in more than 7 times in the region of interest in comparison with the birdcage coil and 2 times versus the dedicated flat local coil.

762
Plasma 8
Development and performance evaluation of the second prototype of a RF-coil integrated PET insert for existing 3T MRI systems
Md Shahadat Hossain Akram1, Fumihiko Nishikido1, Takayuki Obata1, Mikio Suga2, Eiji Yoshida1, Hedeaki Tashima1, Keiji Shimizu3, Masanori Fujiwara2, Akram Mohammadi1, and Taiga Yamaya1

1National Institute of Radiological Sciences, Chiba, Japan, 2Chiba University, Chiba, Japan, 3Hamamatsu Photonics K.K., Hamamatsu, Japan

We developed an RF-coil integrated DOI-PET insert for the 3T MRI system for human brain imaging. In this study we have given details of the second prototype system developed recently and evaluated performance for MRI-only, PET-only and simultaneous PET/MRI conditions. This system included 24 carbon fiber shielded PET modules which are positioned in between the coil-elements of a birdcage head-coil. In total 48 4-layer DOI detectors are included that gives 60 mm axial-FOV for PET imaging. Under all performance study the system worked quite well showing promise for near-future human brain study.

763
Plasma 9
Characterization of a new ultra-flexible, low profile RF receive coil technology.
Philip Rossman1, Robert Stormont2, Scott Lindsay2, Fraser Robb2, Dennis Savitskij2, David Stanley2, John Huston1, Timothy Kaufmann1, and Kiaran McGee1

1Department of Radiology, Mayo Clinic, Rochester, MN, United States, 2GE Healthcare, Waukesha, WI

A new highly flexible RF coil design is described. Individual coil elements are constructed by means of a proprietary process that yields low reactance and low loss conductors while being lightweight, flexible, and durable.  Phantom data indicate that for similar coil geometries, the coils provide equivalent SNR profiles but do not suffer from design limitations due to minimum coil overlap requirements of conventional copper coil elements. In vivo data demonstrate that these coils can be fabricated onto highly flexible and thin support materials that closely comply with anatomic contours in challenging imaging sites such as the c-spine.

764
Plasma 10
Resonance frequency detection of a stretchable RF receiver coil for MRI
Andreas Mehmann1, Christian Vogt1, Benjamin Sporrer2, Matija Varga1, Qiuting Huang2, and Gerhard Troester1

1Electronics Laboratory, ETH Zurich, Zurich, Switzerland, 2Integrated Systems Laboratory, ETH Zurich, Switzerland

Wearable RF receiver coils change their resonance frequency when stretched or bent. We propose a system that detects this change in resonance frequency. The system is integrated on a wearable MRI receiver of 20 x 30mm². The change in resonance frequency can be detected in-field. The detection works by sweeping an excitation current through a frequency range and measuring the frequency response. The frequency response is transmitted via a glass fibre to an out-field signal processing unit. Measurements were conducted using a stretchable liquid metal coil on neoprene.

766
Plasma 12
Dielectric resonator antenna receive array at 7 Tesla using detunable ceramic resonators
Thomas Ruytenberg1 and Andrew Webb1

1Radiology, Leiden University Medical Center, Leiden, Netherlands

A receive-only array of dielectric resonator antennas has been developed. A method for detuning the ceramic resonators is studied using simulations and measurements, after which a four-channel dielectric resonator antenna array is used for in vivo image acquisition of the ankle. Using this receive-only array allows for higher SNR and parallel imaging using SENSE.


767
Plasma 13
Top-Hat Dipole RF Coil with Large Field of View for 7 T Brain MR Imaging
Chang-Hyun Oh1,2,3,4, Chulhyun Lee5, Suchit Kumar3, Jun-Sik Yoon1, Ha-Kyu Jeong6, Jeong-Hee Kim2, Young-Seung Jo1,5, Jong-Min kim1, Christian Bruns7, Tim Herrmann7, Johannes Bernarding7, and Zang-Hee Cho8

1Department of Electronics and Information Technology, Korea University, Seoul, Korea, Republic of, 2Research Institute for Advanced Industrial Technology, Korea University, Sejong City, Korea, Republic of, 3Department of Biomicrosystem Technology, Korea University, Seoul, Korea, Republic of, 4ICT Convergence Technology for Health & Safety, Korea University, Sejong City, Korea, Republic of, 5Korea Basic Science Institute, Cheongju, Chungcheongbuk-do, Korea, Republic of, 6BIU Clinical Science MR, Philips Korea, Seoul, Korea, Republic of, 7Department for Biometrics und Medical Informatics, Otto-von-Guericke University, Magdeburg, Germany, 8Advanced Institutes of Convergence Technology, Seoul National University, Seoul, Korea, Republic of

In ultra-high-field brain MR imaging, the coverage for imaging with the optimized protocol is constrained not only by scan time, but also by the coil structure. Since presently available surface loop RF coils have limited field of view, it is very difficult to achieve the coverage from the top of the head to the end of the cervical vertebrae. Prior solution to this problem was to increase the number of elements. However, it increases the complexity of coil array design thus causing difficulties in construction of the coils. In this paper, an 8-channel top-hat dipole receive RF coil is proposed for the brain imaging at 7 Tesla MRI. By enabling the coil tuning with novel tuning methods for shorter RF coil lengths but still with reasonable uniformity and SNR for more imaging field of view compared with multi-element loop coils.

768
Plasma 14
Bioreactor for in vitro optical fluorescence and magnetic resonance spectroscopy
Benjamin L Cox1,2,3, Joseph M Szulczewski3,4, Kai D Ludwig1, Erin B Adamson1, Robert A Swader2, Sarah A Erickson-Bhatt2,3,4, Patricia J Keely4, Kevin W Eliceiri1,2,3,5, and Sean B Fain1,6

1Medical Physics, University of Wisconsin - Madison, Madison, WI, United States, 2Medical Engineering, Morgridge Institute for Research, Madison, WI, United States, 3Laboratory for Optical and Computational Instrumentation (LOCI), University of Wisconsin - Madison, Madison, WI, United States, 4Cell and Regenerative Biology, University of Wisconsin - Madison, Madison, WI, United States, 5Biomedical Engineering, University of Wisconsin - Madison, Madison, WI, United States, 6Radiology, University of Wisconsin - Madison, Madison, WI, United States

The design and implementation of a novel bioreactor capable of facilitating both magnetic resonance spectroscopy (MRS) and optical fluorescence microscopy for complementary metabolic information is described. Fluorescence lifetime imaging (FLIM) of nicotinamide adenine dinucleotide (NADH) and hyperpolarized [1-13C] pyruvic acid (PA) MRS of human breast cancer cells in a 3D collagen matrix is demonstrated. The system provides a novel test-bed for simulating cell-matrix and cell-cell interactions in a 3D microenvironment for investigating multi-scale cellular metabolism in vitro.

769
Plasma 15
Multimodal Imaging: MR-Compatible, Gradient Artifact free, Wireless recording system integrated with MR-scanner for Simultaneous EEG and fMRI acquisition
Ranajay Mandal1, Nishant Babaria2, Jiayue Cao1, and Zhongming Liu1,2

1Biomedical Engineering, Purdue University, West Lafayette, IN, United States, 2Electrical and Computer Engineering, Purdue University, West Lafayette, IN, United States

The field of multimodal imaging has largely been propelled by two of the most widely used neuroimaging tools, fMRI and EEG, as the complementary nature of the two signals provides a unique avenue to evaluate the brain dynamics and its underlying neural circuitry. However, methodological challenges associated with simultaneous acquisition of EEG and fMRI impedes the method from achieving the full potential. To address these challenges, we present an MR-compatible, active recording system that utilizes surplus MR-hardware and inherent electromagnetic field to synchronize and wirelessly record gradient artifact free multichannel EEG signals and encode these Non-MR signals within the extended FOV of the MR image.

770
Plasma 11
Mary had a little Lamb: Scanner-recorded speech during MRI without gradient-induced sound
Jan Ole Pedersen1,2, Christian Hanson, Rong Xue3, and Lars G. Hanson1,2

1Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital, Kgs Lyngby, Denmark, 2Centre for Magnetic Resonance, DTU Elektro, Technical University of Denmark, Kgs Lyngby, Denmark, 3State Key Laboratory of Brain and Cognitive Science, Research, Institute of Biophysics, Chinese Academy of Sciences

During MRI, fast switching of imaging gradients generate loud noise of high intensity due to vibration of the gradient coils. The in-bore intercom used for patient communication is therefore typically turned off during scanning. This has implications for safety and image quality since patient speech and yells are not heard by the scanner operator. Using standard sequences, we demonstrate that sound can be recorded by MRI scanners and extracted from the scanners raw data, thereby enabling communication with patients for safety or experimental reasons.


Electronic Power Pitch Poster

Poster: Post-Processing & Motion

Exhibition Hall Wednesday 14:45 - 15:45

771
Plasma 16
cBEaST: Cerebellar Brain Extraction based on Nonlocal Segmentation Technique – A comparison with state-of-the-art methods
Daniel Güllmar1, Viktor Pfaffenrot2,3, Rossitza Draganova2, Xiang Feng1, Jürgen R Reichenbach1, Dagmar Timmann2, and Andreas Deistung1,2

1Medical Physics Group, Institute for Diagnostic and Interventional Radiology, Jena University Hospital – Friedrich Schiller-University, Jena, Germany, 2Section of Experimental Neurology, Department of Neurology, Essen University Hospital, Germany, 3Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany

An automatic segmentation of the cerebellum is required to determine the cerebellar volume and for improving spatial normalization in voxel-based analysis approaches. While existing segmentation approaches typically work quite robust in healthy subjects, errors in segmentation increase with cerebellar atrophy and typically require manual corrections. We introduce a novel cerebellum segmentation approach, referred to as cBEaST, that relies on a dedicated multi-resolution segmentation library with manually edited cerebellar masks of both healthy and diseased subjects in combination with multi-atlas-propagation and segmentation as implemented in BEaST. Finally segmentation of the cerebellum with BEaST is compared with the alternative techniques SUIT and FreeSurfer.

772
Plasma 17
Signal-model-based water-fat separation in Zero Echo Time (ZTE) MRI
Romain Nicolas Froidevaux1, Markus Weiger1, Po-Jui LU2, and Klaas Paul Pruessmann1

1University and ETH Zurich, Zürich, Switzerland, 2ETH Zurich, Zurich, Switzerland

The separation of water and fat in zero echo time (ZTE) imaging is challenging for several reasons: First,  echo-based signal models are violated for fast-relaxing spins and require the use of loud sequences. Second, frequency selective preparation pulses produce large SAR and are inefficient on short-T2 compounds. Finally the off-resonance induced phase vanishes at TE = 0. In this work, we introduce the principles of a technique that allows water-fat separation for a single ZTE acquisition and demonstrate it potential and limits with phantom and in-vitro experiments.

773
Plasma 18
Suspicious Component Segmentation for Identifying Hippocampal Sclerosis Using Regularized Tissue-Fraction MR Fingerprinting
Kang Wang1, Congyu Liao2, Xiaozhi Cao2, Zhixing Wang2, Dengchang Wu1, Hongjian He2, Qiuping Ding2, and Jianhui Zhong2

1Department of Neurology, The First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, People's Republic of China, 2Center for Brain Imaging Science and Technology, Department of Biomedical Engineering, Zhejiang University, Hangzhou, People's Republic of China

A relaxometry-based tissue fraction segmentation using MR fingerprinting method was applied for identifying hippocampal sclerosis. The results demonstrated that tissue-fraction MR fingerprinting method could effectively segment multiple tissue components and mark the possible sclerosis regions, which is critical for clinical application including lesions diagnosis and multicomponent analysis.

774
Plasma 19
Improved Short-T2* Estimation with Bloch Equation-Modeled Concurrent Excitation and Relaxation
Ethan M Johnson1, Kim Butts Pauly2, and John M Pauly1

1Electrical Engineering, Stanford University, Stanford, CA, United States, 2Radiology, Stanford University, Stanford, CA, United States

Short-T2* magnetization (order of [0.1,1ms]) can relax appreciably during standard-rate excitation pulses, which can bias estimates of relaxation rates formed by fitting to observed signal decay.  The effect can, however, be included in an updated model to improve T2* estimation for fast-relaxing signals.  Here, a demonstration is presented.

775
Plasma 20
Edge preserving upsampling of image resolution in MRI
Marco Reisert1 and Elias Kellner1

1Dep. of Radiology, Medical Physics, University Medical Center Freiburg, Freiburg, Germany

In this work we present a simple and efficient postprocessing method to isotropify the imaging resolution of MRI imagery. In MRI anisotropic voxel sizes are quite common due to several reasons. Typically the trough-plane voxel size is higher than the in-plane resolution. We propose a simple technique to upsample to isotropic image resolution without introducing the typical block like artifacts known from conventional interpolation schemes. 

776
Plasma 21
Motion-compensated reconstruction of fetal cardiac MRI using a golden-angle radial acquisition, retrospective gating, and compressed sensing
Christopher W. Roy1,2, Mike Seed3,4, and Christopher K. Macgowan1,2

1Medical Biophysics, University of Toronto, Toronto, ON, Canada, 2Physiology and Experimental Medicine, Hospital for Sick Children, Toronto, ON, Canada, 3Pediatric Cardiology, Hospital for Sick Children, ON, Canada, 4Pediatric and Diagnostic Imaging, University of Toronto, Toronto, ON, Canada

Fetal cardiac MRI requires high spatial and temporal resolution but is often limited by stochastic and periodic motion. To compensate for these sources of artifact, a radial golden-angle acquisition was used to acquire and reconstruct real-time fetal cardiac images. In-plane motion and fetal heart rate were then calculated from the real-time images and used to reconstruct reordered CINE images at high spatial and temporal resolution. Using this approach, motion-robust imaging of the fetal heart was successful in seven pregnant volunteers for both short-axis and long-axis multi-slice acquisitions.

777
Plasma 22
From Visualization to Quantification: Calibrating Motion Magnification by Amplified Magnetic Resonance Imaging
Wendy W Ni1, Maged Goubran1, Greg Zaharchuk1, Michael Moseley1, Kristen Yeom1, and Samantha Holdsworth1

1Radiology, Stanford University, Stanford, CA, United States

The brain is constantly in motion.  Changes in the cardio-ballistic motion of brain structures can provide invaluable information on natural processes and pathology.  We have previously introduced a qualitative visualization technique, Amplified MRI (aMRI), to amplify subtle cardio-ballistic motion in the brain.  Now we attempt to quantify the underlying motion through simulation-based characterization of the aMRI technique.  By generating calibration curves for a range of motion parameters, we calculated the unamplified tissue displacement in two human subjects.  The estimated displacements are higher than literature values.  Nevertheless, our simulations are the first steps in benchmarking aMRI’s potential as a quantitative technique.

778
Plasma 23
Assessing the effect of head-motion on tissue volume estimates
Daniel Gallichan1,2

1School of Engineering, Cardiff University, Cardiff, United Kingdom, 2EPFL- CIBM, Lausanne, Switzerland

We looked at data from 60 subjects undergoing 1mm resolution T1-weighted structural scans at 7T with 3D FatNavs allowing retrospective motion-correction. Motion parameters for 60 subjects were examined for general trends – and typical motion was dominated by translation in the z-direction and a small backwards rotation of the head. Quantitative estimates of tissue volumes were compared before and after motion-correction was applied, suggesting that total intracranial volume tends to be overestimated when the subject moves more – and that this is dominated by an overestimation of the CSF volume.

779
Plasma 24
Prospective motion correction on diffusion weighted imaging: improving data quality with four radio frequency and gradient pulses updates.
Danilo Maziero1, Michael Herbst2, and Thomas Ernst3

1University of Hawaii, Honolulu, HI, United States, 2Department of Radiology, University Medical Center Freiburg, Freiburg, Germany, 3Department of Medicine, John A. Burns School of Medicine, University of Hawaii, Honolulu, HI, United States

Prospective Motion Correction (PMC) using fast camera-based tracking systems can dramatically increase DWI data quality and may have an important application in populations where movement is hard to prevent. Here we present images acquired with and without intra-sequence PMC from two subjects realizing fast head rotations up to 30°/s. Our results show that the DWI motion sensitivity can be reduced five-fold by applying 3 intra-sequence PMC updates (prior to each of the two refocusing RF pulse and prior to readout).

780
Plasma 25
Motion corrected high resolution time-of-flight angiography at 7T using Segmented FatNavs
Frédéric Gretsch1 and Daniel Gallichan2

1EPFL, Lausanne, Switzerland, 2School of Engineering, Cardiff, United Kingdom

We propose to insert Segmented FatNavs into a time-of-flight sequence, and use it as a multi-purpose module. It allows fat suppression, magnetization-transfer suppression of the tissue signal, and retrospective motion correction. Image quality was always enhanced after correction, even in cases of small motion, thereby making high-resolution brain angiography more reliable.

781
Plasma 26
Motion correction on a human PET/MR scanner: Clinical feasibility of a motion correction system in patients – an update report
Thomas Küstner1,2, Christian Würslin3, Martin Schwartz2,4, Hadi Fayad5, Thibaut Merlin5, Christopher Gilliam6, Thierry Blu6, Petros Martirosian4, Fritz Schick4, Bin Yang2, Holger Schmidt1, and Nina F Schwenzer1

1Department of Radiology, University of Tuebingen, Tuebingen, Germany, 2Institute of Signal Processing and System Theory, University of Stuttgart, Stuttgart, Germany, 3University of Stanford, Palo Alto, CA, United States, 4Section on Experimental Radiology, University of Tuebingen, Tuebingen, Germany, 5LaTIM, INSERM, University of Bretagne, Brest, France, 6Department of Electronic Engineering, Chinese University of Hong Kong, Hong Kong, Hong Kong

The diagnostic accuracy of Positron-Emission-Tomography/Magnetic Resonance (PET/MR) is often reduced in regions affected by respiratory and cardiac motion. These motion-induced artifacts can be corrected by an MR-derived motion model (MM). Here, we improved the previously presented PET/MR motion correction system by two new sampling trajectories for the MR motion imaging and extend it by the usage of an additional Compressed Sensing reconstruction (BART), an optical-flow based registration (LAP) and the incorporation of motion correction into a listmode-based PET reconstruction (CASToR) which are all integrated into the Gadgetron-based reconstruction pipeline for a clinical feasible setup. In-vivo patient data substantiated the improvements.

782
Plasma 27
Respiratory motion-corrected simultaneous cardiac PET and coronary MR angiography using a hybrid 3T PET-MR
Camila Munoz1, Radhouene Neji1,2, Gastao Cruz1, Rene Botnar1, and Claudia Prieto1

1Division of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom, 2MR Research Collaborations, Siemens Healthcare, Frimley, United Kingdom

Physiological motion remains a major challenge for cardiac PET-MR. Here we propose a framework for non-rigid respiratory motion-corrected simultaneous Coronary MR Angiography (CMRA) and cardiac PET. Motion estimated from low-resolution MR image navigators and from CMRA data itself is used for correcting CMRA and PET datasets to the same respiratory position. The proposed CMRA approach was validated in ten healthy subjects. Results from the PET-CMRA framework on three patients show that motion-corrected PET images have improved sharpness compared to uncorrected reconstructions, whereas motion-corrected CMRA images have improved coronary vessel length and sharpness compared to uncorrected and translational-corrected images.

783
Plasma 28
Beyond the biological resolution limit: Prospectively motion corrected Time of Flight angiography at 7T
Hendrik Mattern1, Alessandro Sciarra1, Frank Godenschweger1, Daniel Stucht1, Falk Lüsebrink1, and Oliver Speck1,2,3,4

1BMMR, Otto-von-Guericke-University, Magdeburg, Germany, 2German Center for Neurodegenerative Disease, Magdeburg, Germany, 3Center for Behavioral Brain Sciences, Magdeburg, Germany, 4Leibniz Institute for Neurobiology, Magdeburg, Germany

Subject motion limits the potential of high resolution Time of Flight (ToF) angiography at 7T, even small scale, involuntary movements can degrade the image quality. In this study, prospective motion correction was able to overcome the biological resolution limit in a healthy subject population (quality assessment with quantitative and qualitative metrics), and was used to acquire the highest in vivo ToF data set to date with an isotropic voxel size of 0.15mm³.

784
Plasma 29
Implementation of a 2.4 GHz wireless sensing platform for transmission of motion data from within a head coil at 3T.
Adam M.J. van Niekerk1, Andre J. W. van der Kouwe1,2,3, and Ernesta M. Meintjes1

1Division of Biomedical Engineering, Human Biology, University of Cape Town, Cape Town, South Africa, 2Athinoula A. Martinos Center, Massachusetts General Hospital, Charlestown, MA, United States, 3Radiology, Harvard Medical School, Boston, MA, United States

Prospective motion correction using external hardware can be compromised by poor marker attachment. In this work we introduce a new attachment site on the mastoid process of the subject. To achieve this, an active wireless marker is implemented that takes advantage of the versatility of an existing method (VectOrient). The effects of the device on the scanner’s operation and visa versa are evaluated. The small 14x16mm2 device shows good MRI compatibility. Any degradation in signal quality is localised and could be further reduced. The link quality is sufficient to stream patient motion parameters, quantifying patient pulse during MEMPRAGE and EPI pulse sequences. 

785
Plasma 30
Respiratory Phase-Matched MR-based Attenuation Correction (MRAC) for Four-Dimensional (4D) PET in PET/MRI: A Feasibility Study
Jaewon Yang1, Florian Wiesinger2, Anne Menini2, Jing Liu1, Thomas A. Hope1, Youngho Seo1, and Peder E. Z. Larson1

1Radiology and Biomedical Imaging, UCSF, San Francisco, CA, United States, 2GE Global Research

PET/MRI is capable of simultaneous respiratory motion-resolved four-dimensional (4D) PET/4D MRI data acquisitions. Therefore, it is important to develop a clinically applicable method for respiratory phase-matched MR-based attenuation correction (MRAC) for accurate 4D PET quantification. This study proposed 4D MRAC protocols modifying the current MRAC protocol and evaluated their performance using a patient with liver metastases. For qualitative analysis, 4D MRAC improved phase-mismatch at the lung/liver interface substantially. For quantitative analysis, 4D MRAC improved PET quantification by 10-30% increase of PET-avid tumor uptake values, compared to static MRAC, specifically for the tumors located at the lung/liver interface. 


Electronic Power Pitch Poster

Poster: Diffusion: Outside the Brain

Exhibition Hall Wednesday 17:15 - 18:15

Plasma 16

862
Plasma 1
Analysis of abdominal movement with Phase Optical Flow: Application to Diffusion imaging.
Stephan Hahn1, Maxime Gérard1, Damien Dasnoy-Sumell1, Julie Absil2, Olivier Debeir1, and Thierry Metens2

1Laboratories of Image, Signal processing and Acoustics, ULB, Brussels, Belgium, 2MRI Clinics&Radiology, Hôpital Erasme, Brussels, Belgium

We present a new method, the Phase Optical Flow, which provides an automatic determination of abdominal regional movements along the cardiac cycle and allows a real time determination of the optimal cardiac trigger time to be used in quantitative liver DWI. A phase based motion amplification was applied to real-time BTFE images acquired at 20 images/s. Then optical flow was used to derive the velocity vector field. The optimal cardiac time window was defined as the 100ms-period with minimal absolute vertical velocity. Validation was provided by liver DWI obtained at several cardiac trigger times.

863
Plasma 2
In vivo imaging of mean cell size and density of human breast tumors
Hua Li1,2, Lori R. Arlinghaus1,2, A. Bapsi Chakravarthy3, Vandana G. Abramson2, John C. Gore1,2, and Junzhong Xu1,2

1Institute of Imaging Science, Vanderbilt University, Nashville, TN, United States, 2Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN, United States, 3Department of Radiation Onology, Vanderbilt University, Nashville, TN, United States

We report a new MRI method termed IMPULSED (Imaging Microstructural Parameters Using Limited Spectrally Edited Diffusion) to quantitatively characterize mean cell size and density in solid tumors simultaneously and the first application of this method in breast cancer patients.

864
Plasma 3
Intravoxel incoherent motion MR imaging for staging liver fibrosis and monitoring anti-fibrotic response to losartan: an experimental study in rat model
Caiyuan Zhang1, Yong Zhang2, and Dengbin Wang1

1Radiology, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China, 2MR Research China, GE Healthcare, Shanghai, China, Shanghai, People's Republic of China

To evaluate the feasibility of intravoxel incoherent motion (IVIM) MR imaging to stage liver fibrosis and its capability for monitoring anti-fibrotic response to treatment, we performed IVIM MR imaging for rats model induced by carbon tetrachloride and for rats treated with losartan. Our studies demonstrated that D* is helpful to stage early and moderate fibrosis, and f is beneficial to discriminate advanced liver fibrosis and cirrhosis. In losartan treated rats, D* and f showed statistical significance compared with CCl4 alone. We concluded that perfusion parameters derived from IVIM have potential to monitor fibrosis progression and evaluate anti-fibrosis response to treatment.

865
Plasma 4
Diffusion-weighted MRI and coherent flow in the kidney
Andreas Max Weng1, Fabian Hilbert1, Henning Neubauer1, Simon Veldhoen1, Thorsten Alexander Bley1, and Herbert Köstler1

1Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Würzburg, Germany

The IVIM model and typical DWI-evaluations assume flow in tissue to be incoherent. However, there is evidence that in some tissues flow might be coherent and thus, the DWI-signal might be influenced by the applied first gradient moment m1. A gradient scheme was implemented that allows applying different m1 for a constant b-value. Moreover, the IVIM model was extended to also include coherent flow in the modeling process of DWI data. It was found that flow in the human kidney is, at least in part, coherent and that the proposed model is able to fit that data very robustly.

866
Plasma 5
An assessment of Intravoxel Incoherent Motion (IVIM) imaging in Detection of Acute Kidney Injury in Rodents
Keisuke Ishimatsu1, Shanrong Zhang1, Koji Sagiyama1, Ming Chang Hu2, Orson W Moe2, and Masaya Takahashi1

1Advanced Imaging Researh Center, UT Southwestern Medical Center, Dallas, TX, United States, 2Department of Internal Medicine / Charles and Jane Pak Center of Mineral Metabolism and Clinical Research, UT Southwestern Medical Center, Dallas, TX, United States

The objective is to investigate the concept of intravoxel incoherent motion (IVIM) for diffusion weight imaging (DWI) in the kidney. We first compared the variability of three methods for bi-exponential fitting applied to the five data sets of DWI obtained in a mouse kidney. Subsequently these three methods were compared with an arterial spin labeling (ASL) in detection of acute kidney injury (AKI) in a rat model. The IVIM imaging did not detect any changes in the AKI model although the ASL clearly demonstrated the reduction of the perfusion. 

867
Plasma 6
Diffusion-Weighted MRI Identifies Viable Tissue in Wilms Tumour: Application for Subtype Analysis and Response to Chemotherapy
Harriet Rogers1, Patrick Hales1, Kathy Pritchard-Jones2, and Christopher Clark1

1Developmental Imaging and Biophysics, Institute of Child Health, University College London, London, United Kingdom, 2Developmental Biology and Cancer, Institute of Child Health, University College London, London, United Kingdom

In Wilms Tumour (WT) Blastemal subtype has the worst prognosis. Diffusion MRI (DWI) can distinguish some histological subtypes. Gadolinium-contrast-injected T1 MRI (T1gad) identifies necrotic tissue. Gadolinium is contra-indicated in renal failure. 27 patients received DWI, 20/27 received T1gad. DWI was fitted with Intravoxel Incoherent Motion providing Dmaps. Viable and necrotic regions identified on T1gad were transferred to corresponding Dmaps. ROC analysis determined a D threshold separating necrotic and viable tissue. ANOVAs showed viable regions separated Blastemal from other subtypes, whole lesions could not. DWI separates necrotic and viable tissue in WT potentially identifying subtypes, assessing chemotherapy, guiding biopsies and surgery. 

868
Plasma 7
Validation of VERDICT MRI using fresh and fixed prostate specimens with aligned histological slices
Colleen Bailey1, Roger M Bourne2, Bernard Siow3,4, Edward W Johnston5, Hayley Pye6,7, Susan Heavey6,7, Thomy Mertzanidou1, Hayley Whitaker6, Alexander Freeman8, Dominic Patel8, Greg Shaw6,7, Ashwin Sridhar6,7, Shonit Punwani5, David J Hawkes1, Daniel C Alexander1, and Eleftheria Panagiotaki1

1Centre for Medical Image Computing, University College London, London, United Kingdom, 2Discipline of Medical Radiation Sciences, University of Syney, Sydney, Australia, 3Centre for Advianced Biomedical Imaging, University College London, London, United Kingdom, 4Imaging, Francis Crick Insitute, London, United Kingdom, 5Centre for Medical Imaging, University College London, London, United Kingdom, 6Division of Surgery and Interventional Science, University College London, London, United Kingdom, 7Department of Urology, University College London Hospitals, London, United Kingdom, 8Department of Research Pathology, University College London, London, United Kingdom

This study provides the first step in validating the VERDICT diffusion model of tissue microstructure by examining the effects of fixation on tissue microstructure and comparing VERDICT parameter maps to histological features. Fresh and fixed parameter maps showed similar spatial trends: fixation decreased the extracellular volume fraction parameter and decreased the cell radius parameter slightly, consistent with water efflux. Intracellular volume fraction was lower in regions with lower cellularity, such as the peripheral zone, and directions of diffusion anisotropy corresponded with collagen and smooth muscle orientation patterns in the stroma.

869
Plasma 8
Diffusion-weighted MRI in the evaluation of posttherapeutic residual masses in lymphoma
Siarhei Kharuzhyk1, Edward Zhavrid2, and Nina Sachivko2

1Radiology, N.N. Alexandrov National Cancer Center, Minsk, Belarus, 2Chemotherapy, N.N. Alexandrov National Cancer Center, Minsk, Belarus

Residual masses do often present on posttreatment imaging in lymphoma. We conducted prospective study to evaluate diagnostic capabilities of CT, MRI and diffusion-weighted MRI (MRI-DWI) in differentiation residual tumors and non-active posttreatment masses in 40 lymphoma patients. MRI-DWI with visual analysis of apparent diffusion coefficient (ADC) maps was the most effective technique. Quantitative ADC analysis is a promising tool for differentiation of active and non-active residual masses in lymphoma.

870
Plasma 9
The clinical evaluation of combining DWIBS with whole body T1w imaging for diagnosing bone marrow involvement in lymphoma patients: a comparison with PET/CT
Mengtian Sun1, Jingliang Cheng1, Yun Meng1, and Zhizheng Zhuo2

1The First Affiliated Hospital of Zhengzhou University, 1st, Zhengzhou, People's Republic of China, 2Philips Healthcare, Beijing, People's Republic of China

This study aimed to evaluate the value of the combination of DWIBS (diffusion weighted imaging with background signal suppression) with whole body T1w imaging  for diagnosing bone marrow involvement (BMI) in lymphoma patients, compared to PET/CT imaging. In the first part of this study, patients with newly diagnosed lymphoma were includedand whole body DWIBS, T1w and PET/CT images were acquired for all 20 subjects. For the assessment of individual lesions, DWIBS with whole body T1w has advantages over DWIBS and has similar ability with PET/CT to detect BMI lesions.

871
Plasma 10
Intravoxel incoherent motion diffusion-weighted imaging for discriminating the pathological response to neoadjuvant chemoradiotherapy in locally advanced rectal cancer
Wen Lu1, Yu xiaoping1, and Zhang zhongping2

1Hunan Cancer Hospital, Chang sha, People's Republic of China, 2GE Healthcare China, Beijing, People's Republic of China

In this study, we investigated the utility of IVIM-DWI in discriminating the pathological response to nCRT in locally advanced rectal cancer (LARC). We found that both the pre-nCRT and post-nCRT IVIM-DWI parametric values for LARC, together with their percentage changes, might benefit the evaluation of pathological response to nCRT, which suggest IVIM-DWI is potentially useful in discriminating pathological response for LARC patients.

872
Plasma 11
The value of diffusion kurtosis imaging in assessing pathological complete response to neoadjuvant chemoradiation therapy in rectal cancer: a comparison with conventional diffusion-weighted imaging
Fei-Xiang Hu1, Tong Tong1, Wei Tang1, Yi-Qun Sun1, Dang Wang1, San-Jun Cai2, Zhen Zhang3, Grimm Robert4, Xu Yan5, Cai-xia Fu6, and Wei-Jun Peng1

1Radiology, Fudan University Shanghai Cancer Center, Shanghai, People's Republic of China, 2Colorectal Surgery, Fudan University Shanghai Cancer Center, Shanghai, People's Republic of China, 3Radiotherapy, Fudan University Shanghai Cancer Center, Shanghai, People's Republic of China, 4MR Applications Predevelopment, Siemens Healthcare GmbH, Germany, 5MR Collaboration NE Asia, Siemens Healthcare, People's Republic of China, 6APPL, Siemens Shenzhen Magnetic Resonance Ltd., People's Republic of China

The aim of this study was to evaluate the performance of diffusion kurtosis imaging (DKI) in predicting pathological complete response (pCR) of locally advanced rectal cancer (LARC) to neoadjuvant chemoradiation therapy (CRT) before and at an early stage of the treatment, and in comparison to conventional diffusion-weighted imaging (DWI). Results showed that DKI outperformed conventional DWI in accurately differentiating between pCR and nonPCR patients who received neoadjuvant chemoradiation therapy both before and at an early stage of treatment.

873
Plasma 12
The application of whole lesion IVIM analysis using iZOOM DWI in the diagnosis of thyroid tumor
Yunlong Yue1, Lili Zuo1, Kaining Shi2, Lee Jiang3, Jinsong Guo1, and Yanfang Jin1

1Department of MR, Beijing Shijitan hospital of capital medical university, Beijing, People's Republic of China, 2Philips Healthcare (China), Beijing, People's Republic of China, 3Philips Healthcare (China), Suzhou, People's Republic of China

To explore the ability of IVIM parameters derived from iZoom DWI in differentiating malignant thyroid nodules from benign ones. 40 patients with 45 pathologically proven thyroid nodules were involved. iZOOM DWI with 2D RF was employed to decrease the distortion and carotid coil was used to increase the SNR. 3D ROI was drawn manually to cover the whole lesion. D and f values were significantly lower in malignant nodules than in benign nodules. According to ROC curve analysis IVIM almost reached the upper limit of the accuracy based on US.

874
Plasma 13
Diffusion Spectrum Imaging Tractography of the Human Tongue
Nahla M H Elsaid1, Maureen Stone2, Steven Roys1, Rao P Gullapalli1, Jerry L Prince3, and Jiachen Zhuo1

1Diagnostic Radiology, University of Maryland School of Medicine, Baltimore, MD, United States, 2Neural and Pain Sciences and Orthodontics, University of Maryland Dental School, Baltimore, MD, United States, 3Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, United States

The human tongue is known to have a complex architecture of muscles. To fully understand how the muscle fibers are connected and how their relative position could affect the tongue functionality, diffusion weighted imaging is needed. Diffusion Spectrum Imaging (DSI) is able to characterize the fiber structure on a sub-voxel level including the fiber crossing or branching. As DSI sequences are usually time-consuming, in-vivo studies using DSI can be challenging. In this study, we present for the first time DSI of the post-mortem human tongue. and the associated tractography delineating the tongue muscle fibers. DSI has the ability to identify fiber crossings within the human tongue.

875
Plasma 14
Acquisition at maximum blood velocity overcomes the problem of the ill-posedness of the IVIM model: a demonstration with renal diffusion MRI
Bastien Milani1, Jean-Baptiste Ledoux2, and Menno Pruijm3

1Nephrology, CHUV, Lausanne, Switzerland, 2Radiology, CHUV, 3Nephrology, CHUV

We explain why diffusion MRI should always be acquired when blood has maximum velocity in the organ of interest. We first give some theoretical arguments to support this hypothesis. We then demonstrate it with numerical experiments and with in-vivo experiments.

876
Plasma 15
Comparison of in-vivo Lung Morphometry Models from 3D Multiple b-value 3He Diffusion-Weighted MRI
Ho-Fung Chan1, Juan Parra-Robles1,2, Guilhem J Collier1, and Jim M Wild1

1Academic Unit of Radiology, University of Sheffield, Sheffield, United Kingdom, 2Department of Bioengeering, Universidad Carlos III de Madrid, Madrid, Spain

The cylinder (CM) and stretched exponential (SEM) models have been proposed as a means of estimating lung alveolar microstructural length scales (L­m for CM and LmD for SEM) from multiple b-value hyperpolarised gas DW-MRI. This work compares Lm and LmD in healthy normals, idiopathic pulmonary fibrosis, and COPD patients. A correlation with a non-linear trend was observed between the Lm and LmD parameters. This suggests that the two models have different operational ranges of length scale estimation accuracy due to inherent differences in their geometrical and mathematical assumptions.


Electronic Power Pitch Poster

Poster: MRS/MRSI Applications

Exhibition Hall Wednesday 17:15 - 18:15

877
Plasma 16
Resolution Enhanced accelerated Four Dimensional Echo Planar Spectroscopic Imaging: Application in Prostate Cancer
Zohaib Iqbal1, Brian L. Burns1, Rajakumar Nagarajan1, Robert E. Reiter2, Steven S. Raman1, and M. Albert Thomas1

1Radiological Sciences, University of California - Los Angeles, Los Angeles, CA, United States, 2Urology, University of California - Los Angeles, Los Angeles, CA, United States

Prostate cancer (PCa) remains the most prevalent form of cancer in men. For diagnosis, Prostate-Specific Antigen (PSA) levels are most commonly used as a screening tool. Chemical shift imaging (CSI) methods can provide information on the biochemical concentrations of metabolites in different regions of the prostate. Here, we demonstrate a novel technique capable of improving the spatial and spectral resolution of the accelerated echo-planar J-resolved spectroscopic imaging (EP-JRESI) method, which obtains 2 spatial and 2 spectral dimensions in a single scan. This resolution enhanced EP-JRESI (RE-JRESI) method is evaluated in PCa patients and compared to the EP-JRESI results.

878
Plasma 17
Initial results of combined 1H and 31P spectroscopic imaging of the prostate at 7 Tesla
Bart WJ Philips1, Mark van Uden1, and Tom WJ Scheenen1

1Radiology and Nuclear Medicine, Radboud University Medical Centre Nijmegen, Nijmegen, Netherlands

Proton MR spectroscopy has proven to be a valuable tool in the evaluation and detection of prostate cancer by assessing metabolite ratios incorporating choline and citrate signals. The choline peak in the proton spectrum actually consists of several different peaks of choline containing compounds[2], of which some can be distinguished using 7 Tesla 31P spectroscopic imaging. In this work we present our first patient results of a method that combines 31P and 1H within one measurement using a 31P Tx/Rx and 1H Rx endorectal coil and we show its feasibility for correlating 31P and 1H metabolite ratios.

879
Plasma 18
Reduced GABA levels correlate with cognitive impairment in relapsing-remitting multiple sclerosis
Guanmei Cao1, Bin Zhao1, Guangbin Wang1, Weibo Chen2, and Fei Gao1

1Shandong Medical Imaging Research Institute,Shandong University, Jinan,Shandong, People's Republic of China, 2Philips Healthcare, Shanghai, China, People's Republic of China

To investigate whether cognitive impairment in relapsing-remitting multiple sclerosis (RRMS) is associated with alterations in brain gamma-aminobutyric acid (GABA) levels, 31 RRMS patients and 26 healthy controls underwent 3T 1H MRS and neuropsychologic assessment. GABA levels were quantified in the posterior cingulate cortex (PCC), the medial prefrontal cortex (mPFC) and left hippocampus (LHC). Patients showed reduced GABA+ in PCC and LHC, and reduced GABA+ levels correlated with cognitive function. This study demonstrates that abnormalities of the GABAergic system may be an important neurochemical mechanism of cognitive impairment in RRMS. 

880
Plasma 19
Patch-based super-resolution of MRSI data in multiple sclerosis patients at 7 T
Saurabh Jain1, Gilbert Hangel2, Diana Sima1,3, Wolfgang Bogner2,4, Siegfried Trattnig2,4, Sabine Van Huffel3,5, Frederik Maes5,6, and Dirk Smeets1,7

1icometrix, R&D, Leuven, Belgium, 2High Field MR Centre, Medical University of Vienna, Vienna, Austria, 3Department of Electrical Engineering-ESAT, STADIUS Center for Dynamical Systems, Signal Processing and Data Analytics, KU Leuven, Leuven, Belgium, 4Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria, 5Medical IT, iMinds, Leuven, Belgium, 6Department of Electrical Engineering-ESAT, PSI Medical Image Computing, KU Leuven, Leuven, Belgium, 7BioImaging Lab, Universiteit Antwerpen, Antwerp, Belgium

The clinical application of brain MRSI is, upon several factors, limited by the comparatively low resolution that makes it difficult to resolve lesions. This work demonstrates the application of a patch-based super-resolution (PBSR) method that increases the spatial resolution of metabolite maps obtained from MRSI. The method is validated against conventional interpolation techniques in multiple sclerosis patient measurements. Our results clearly show the benefits of PBSR over other common interpolation techniques.

881
Plasma 20
Cervical spinal cord and brain MRS alterations in normal appearing white matter of multiple sclerosis (MS) patients at 3T
Patrik Oliver Wyss1,2,3,4, Anke Henning1,2,5, Andreas Hock1,6, Andreas Lutterotti7, Roland Martin7, and Spyros Kollias4

1Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland, 2Max Planck Institute for Biological Cybernetics, Tuebingen, Germany, 3Swiss Paraplegic Centre, Nottwil, Switzerland, 4Institute of Neuroradiology, University Hospital Zurich, Zurich, Switzerland, 5Institute of Physics, Ernst-Moritz-Arndt University Greifswald, Greifswald, Germany, 6Department of Psychiatry, Psychotherapy and Psychosomatics Hospital of Psychiatry, University of Zurich, Zurich, Switzerland, 7Neuroimmunology and Multiple Sclerosis Research, Department of Neurology, University Hospital and University Zurich, Zurich, Switzerland

This investigation explores alterations of both cervical spinal cord and brain metabolite levels in normal appearing tissue in patients suffering from multiple sclerosis (MS). In the brain, a 2 dimensional J-resolved spectroscopy sequence and 2D prior-knowledge fitting is used and the metabolite cycling technique is applied to the cervical spinal cord at 3T. Relapsing-remitting MS (RRMS) and secondary progressive MS (SPMS) patients are included and alterations between brain and spinal cord metabolites are addressed.

882
Plasma 21
1H-NMR of carnosine combined with 31P-NMRS to better characterize skeletal muscle pH dysregulation in Duchenne muscular dystrophy
Harmen Reyngoudt1,2, Suna Turk1,2, and Pierre G. Carlier1,2

1NMR Laboratory, Institute of Myology, Paris, France, 2CEA, DRF, I²BM, MIRCen, Paris, France

The finding of an alkaline Pi pool has been established with 31P-NMRS in healthy resting skeletal muscle and the dystrophic muscle of GMRD dogs and DMD patients. The pH values corresponding to this Pi pool corresponds better with extracellular pH. Intracellular pH, however, can also be measured with 1H-NMRS, using carnosine. In a group of DMD patients, we observed that pH determined with 31P-NMRS were systematically increased, whereas this was not always the case for pH based on the measurement of carnosine, revealing two groups in dystrophic muscle: (1) pH elevated with 31P and 1H and (2) pH only elevated with 31P.   

883
Plasma 22
Apparent short transverse relaxation time of inorganic phosphate in breast cancer tissue at 7 tesla.
Wybe JM van der Kemp1, Tijl A van der Velden1, Alexander M Schmitz1, Kenneth G Gilhuijs1, Peter R Luijten1, Dennis WJ Klomp1, and Jannie P Wijnen1

1Department of Radiology, UMC Utrecht, Utrecht, Netherlands

Here we show in a patient group with breast cancer an apparent shortening of the transverse relaxation time of the Pi signal at 7 tesla, as compared to healthy breast fibroglandular tissue and propose an underlying mechanism to explain this observation.

884
Plasma 23
Acetate metabolism towards fatty acids is down-regulated in IDH1 mutant glioma as shown by 13C MRS
Chloé Najac1, Marina Radoul1, Pavithra Viswanath1, Myriam M Chaumeil1, and Sabrina M Ronen1

1Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, United States

IDH1 is the most prevalent driver mutation in lower-grade glioma and upgraded glioblastoma and is associated with additional metabolic reprogramming. Here, we investigated fatty acid biosynthesis and the role of acetate, which was recently recognized as a major fuel in primary glioblastoma. Labeling cells harboring either wild-type or mutant IDH1 with [1,2-13C]-acetate, we found a decrease in flux towards fatty acids in mutant IDH1 cells although the total fatty acid pools remained unchanged. Associated with cell biological assays, these results point to alternate sources for maintenance of fatty acid levels in IDH1 mutant cells. 

885
Plasma 24
Automatic tissue-type classification of 1H-MRSI spectra in patients with glioblastoma
Nuno Pedrosa de Barros1, Raphael Meier2, Martin Pletscher1, Urspeter Knecht1, Mauricio Reyes2, Roland Wiest1, and Johannes Slotboom1

1SCAN / Neuroradiology, University Hospital Bern (Inselspital), Bern, Switzerland, 2Institute for Surgical Technology & Biomechanics, University of Bern, Bern, Switzerland

Clinical-routine MRSI-data analysis is commonly performed through the visual inspection of multiple metabolite and metabolite-ratio maps, and aims at translating the different spectroscopic patterns into known tissue-types, such as, necrosis, solid tumour, tumour-infiltration, normal-brain-tissue, etc. Such translation/segmentation requires solid expertise in MR-spectroscopy, which most clinicians do not have. Bad-quality-data, as well as frequency-dependant-selection-profiles further complicate proper interpretation of MRSI-data. Therefore, to facilitate the clinical-use of MRSI, we present an automatic MRSI-tissue-type segmentation algorithm, that includes automatic-quality-filtering and selection-profile-correction. The method was tested in glioblastoma and the tissue-types were compared against an MRI-based tumour-segmentation-method.

886
Plasma 25
High and Ultra-High Field Proton MR Spectroscopy in Early Amyotrophic Lateral Sclerosis
Ian Cheong1, Malgorzata Marjanska, Dinesh Deelchand, Lynn Eberly, David Walk, and Gulin Oz

1University of Minnesota Twin Cities, Minneapolis, MN, United States

Amyotrophic lateral sclerosis (ALS) is a devastating disease of motor neurons with unknown etiology. Evidence suggests that the brain undergoes degenerative changes in ALS, particularly within areas of the descending motor pathway. Identifying robust and non-invasive biomarkers that are sensitive to neurodegeneration in ALS is essential for improving clinical trial design and assessment of treatment effectiveness. This study evaluated 1H-MRS-measured metabolite levels as biomarkers of disease severity. Ultra-high field (7 tesla) 1H-MRS revealed metabolic abnormalities in the motor cortex and brainstem of humans with ALS that are dependent on disease stage. 

887
Plasma 26
Detection of in vivo biomarkers in fungal brain infection models and potential determination of cell viability.
Liesbeth Vanherp1, Amy Hillen1, Jennifer Poelmans1, Katrien Lagrou2, Greetje Vande Velde1, and Uwe Himmelreich1

1Imaging and Pathology, University of Leuven, Leuven, Belgium, 2Laboratory of Clinical Bacteriology and Mycology, University of Leuven, Leuven, Belgium

Animal models of cerebral infection by the pathogenic fungi Cryptococcus neoformans and C. gattii were developed and assessed longitudinally by using anatomical and diffusion MRI as well as MR spectroscopy. MR spectroscopy identified in vivo biomarkers for potential etiological diagnosis and more importantly for quantification of the fungal load in living animals. Our results have great potential to assist in the differential diagnosis of brain lesions in patients, whereby MR spectroscopy is a safer, non-invasive and rapid method in comparison to traditional invasive diagnostic methods such as CSF sampling or biopsies.

888
Plasma 27
Metabolic variability in a brief status epilepticus model
Jullie W Pan1, Yijen Wu2, Patrice Pearce3, Nihal de Lanerolle4, and Kevin Kelly5

1MRRC, University of Pittsburgh, Pittsburgh, PA, United States, 2Developmental Biology, Children's Hospital Pittsburgh, Pittsburgh, PA, 3Neurology, University of Pittsburgh, Pittsburgh, PA, 4Neurosurgery, Yale University, 5Allegheny Singer Research Institute, Pittsburgh, PA

This study uses short echo MR spectroscopy (TE 10ms) to study the metabolic changes seen in a status epilepticus kainate rodent model. Applied with a brief period (45min) of seizures, a hierarchical cluster analysis is performed on the spectroscopic changes measured 3days after the status injury. These data displayed a bimodal distribution characterizing two groups of animals, “more” or “less” injured. The classification persists into a repeat MRS measurement performed at 3wk, with the less injured group being able to recover; the more injured group did not recover well. Finally, this classification was consistent with Nissl based histological analysis.

889
Plasma 28
Polyunsaturated fatty acid (PUFA) is associated with tumour grading – An ex vivo study on whole breast tumours using multiple quantum coherence (MQC) MRS
Sai Man Cheung1, Ehab Husain2,3, Yazan Masannat3,4, Klaus Wahle3,5, Steven D Heys3,4, and Jiabao He1

1Aberdeen Biomedical Imaging Centre, University of Aberdeen, Aberdeen, United Kingdom, 2Pathology Department, Aberdeen Royal Infirmary, Aberdeen, United Kingdom, 3School of Medicine, University of Aberdeen, Aberdeen, United Kingdom, 4Breast Unit, Aberdeen Royal Infirmary, Aberdeen, United Kingdom, 5Strathclyde Institute of Pharmacy and Biological Sciences, Glasgow, United Kingdom

Eicosanoids are derivatives of three different PUFA, vital in membrane formation and anti-inflammatory control. The presence of eicosanoids in adipose tissue and fibroblasts governs the release of signalling agents in breast, stimulating the invasion of breast cancer cells. Lipid composition has emerged as a potential predictor of breast cancer. However, current research focuses on the tumour initiation, while the understanding of lipid function in tumour progression remains sparse. We therefore hypothesise that there is a difference in PUFA concentration between grade II and III breast cancer. We applied MQC MRS for accurate PUFA measurement on freshly excised whole breast tumours.

890
Plasma 29
In-Vivo Regional detection of Gly in Human Brain: Implications in Glioma Patients at 3T
Vivek Tiwari1, Zhongxu An1, Sandeep Kumar Ganji1, and Changho Choi1

1Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX, United States

Glycine, an inhibitory-neurotransmitter and a co-agonist of N-Methyl-D-aspartate, has been implicated in rapid cancer cell-proliferation and is elevated in high-grade gliomas than low-grade. Gly concentrations range from 0.5-1.0 M in normal brain and exhibits regional-variation. Given such a low in-vivo concentration of Gly, potential overlap from mI and regional-variation, here we have developed a novel Gly-optimized single-voxel-localized triple-refocusing scheme for precise co-detection of Gly and mI in Gray-matter (GM)-rich Medial-Occipital (MO) and White-matter (WM) rich Left-Parietal (LP) healthy-brain region, and further extended to measure glycine level in glioma patients.

891
Plasma 30
Differential diagnosis of Hepatic metabolites between non-alcoholic steatohepatitis and simple steatosis in humans and a murine model using a 1H MR spectroscopy study with long TE
Tae-Hoon Kim1, Hong Young Jun1, Chang-Won Jeong1, Jong-Hyun Ryu1, Kou Gyeom Kim1, and Kwon-Ha Yoon2

1Radiology, Imaging Science Research Center, Iksan, Korea, Republic of, 2Radiology, Wonkwang University School of Medicine, Iksan, Korea, Republic of

Liver biopsy is the gold standard for diagnosing non-alcoholic fatty liver disease(NAFLD) but with practical constraints. MR spectroscopy(MRS) allows in vivo assessment of hepatocellular metabolism and has shown potential for biochemical differentiation in diffuse liver disease. Recent 13C-MRS demonstrated that alanine and lactate levels in inflammatory liver injury were increased compared to those in normal liver, and these changes were positively correlated with liver enzyme levels. However, the clinical use of 13C-MRS technique is limited because it necessitates 13C-resonance specific hardwares and softwares for data acquisition. This study used long TE 1H-MRS to monitor changes of hepatocellular metabolites in NAFLD.


Electronic Power Pitch Poster

Poster: Breakthrough Methods & Applications in Cancer Imaging

Exhibition Hall Thursday 9:15 - 10:15

977
Plasma 1
High resolution imaging of the optic chiasm at 7T MRI improves lesion detection and tumour delineation compared to 3T
Guido van Haren1, Lorna Grech-Fonk2,3, Marco Verstegen4, Wouter Teeuwisse2, Teresa Ferreira1, Irene Notting3, Wouter van Furth4, Alberto Pereira5, Gregorius Luyten3, Andrew Webb2, and Jan-Willem Beenakker2,3

1Radiology, LUMC, Leiden, Netherlands, 2Radiology, CJ Gorter center for high field MRI, LUMC, Leiden, Netherlands, 3Ophthalmology, LUMC, Leiden, Netherlands, 4Neurosurgery, LUMC, Leiden, Netherlands, 5Endocrinology, LUMC, Leiden, Netherlands

The limited resolution of 3Tesla MRI often leads to missed lesions or ambiguities in the tumour environment for patients with a pituitary macro-adenoma. In this study we developed a robust high-resolution 7Tesla MRI-protocol of the optico-chiasmatic system and evaluated its clinical value. The 7T MR-images reveal tiny lesions in the optic nerve or chiasm which are not visible at 3T. These lesions could explain the vision loss for 3 of the 7 evaluated patients and gave the physician new treatment possibilities. Overall, this study shows the great clinical opportunities of 7Tesla MRI for patients with pituitary macro-adenoma or other neuro-ophthalmic conditions.

978
Plasma 2
Accelerated 3D bSSFP Imaging for Treatment Planning on an MRI-Guided Radiotherapy System
Yu Gao1,2, Ziwu Zhou1, Fei Han1, Percy Lee2,3, Daniel Low2,3, Peng Hu1,2, and Yingli Yang2,3

1Radiology, University of California, Los Angeles, Los Angeles, CA, United States, 2Physics and Biology in Medicine IDP, University of California, Los Angeles, Los Angeles, CA, United States, 3Radiation Oncology, University of California, Los Angeles, Los Angeles, CA, United States

The purpose of this work is to introduce a compressed sensing and parallel imaging combined technique to reduce the acquisition time for planning MR. We implemented a variable-density Poisson-Disk under-sampled acquisition along with L1-ESPIRiT reconstruction technique on an MRI-guided radiotherapy system. Phantom study showed that our technique had superior image quality over the conventional GRAPPA approach. Patient and volunteer study demonstrated that comparable images can be acquired with half of the original time. In addition, the proposed technique was able to achieve high resolution imaging where the GRAPPA approach failed due to high noise level. 

979
Plasma 3
Feasibility of magnetic resonance colonography for an immune check-point inhibitor in orthotopic colorectal rechallenge tumor models
Jinil Kim1, Yoon Seok Choi2, Dong-Cheol Woo1, Chul-Woong Woo1, Sang Tae Kim1, Jae Im Kwon1, and Kyung Won Kim3

1Asan Institute for Life Sciences, ASAN Medical Center, Seoul, Korea, Republic of, 2Medical research institute, Gangneung Asan Hospital, Gangneung, Korea, Republic of, 3Department of Radiology, ASAN Medical Center, Seoul, Korea, Republic of

In the immunotherapy research field, establishing appropriate preclinical model is very important to evaluate the complex immune reaction. Orthotopic tumor model is more physiologic than ectopic tumor model, however its use may be limited due to difficulty in evaluating deep-seated tumors, especially in the colorectum having a complex anatomy. MR colonography (MRC) is a new technique in preclinical trial, which uses Fluorinert, a negative contrast agent, to fill the colorectum. Our study demonstrated that MRC is quite feasible to evaluate colorectal tumors and metastatic foci in orthotopic colorectal tumor model, which can be useful in immunotherapy drug development.

980
Plasma 4
Multi-modal and multi-scale measurement of metabolism in vivo in a breast cancer model
Benjamin L Cox1,2,3, Joseph M Szulczewski3,4, David R Inman4, Erin B Adamson1, Kai D Ludwig1, Justin J Jeffery5, Stephen A Graves1, Alison B Roth1, David B Mummy1,6, Patricia J Keely4, Kevin W Eliceiri1,2,3,5,6, and Sean B Fain1,7

1Medical Physics, University of Wisconsin - Madison, Madison, WI, United States, 2Medical Engineering, Morgridge Institute for Research, Madison, WI, United States, 3Laboratory for Optical and Computational Instrumentation (LOCI), University of Wisconsin - Madison, Madison, WI, United States, 4Cell and Regenerative Biology, University of Wisconsin - Madison, Madison, WI, United States, 5UW Carbone Cancer Center, Madison, WI, United States, 6Biomedical Engineering, University of Wisconsin - Madison, Madison, WI, United States, 7Radiology, University of Wisconsin - Madison, Madison, WI, United States

Performing MRI, PET/CT, and optical imaging at the cellular scale in vivo provides highly complementary information as a powerful tool to study cancer metabolism. Recent development of implanted optical windows allows for optical imaging in vivo. Here, we demonstrate multi-modal and multi-scale imaging of tumor progression in a mouse model of breast cancer by performing optical imaging through an implanted window, and whole-body MRI and PET/CT in a single day. The challenge of PET-MR registration is also addressed using dual-PET-MR fiducial markers embedded in a custom-imaging tray.

981
Plasma 5
Dynamic Glucose Enhanced MRI - A prospective study in healthy volunteers and glioblastoma patients
Daniel Paech1, Patrick Schuenke2, Christina Koehler1, Johannes Windschuh2, Sibu Mundiyanapurath3, Sebastian Bickelhaupt1, Philipp Bäumer1, David Bonekamp1, Martin Bendszus4, Wolfgang Wick3, Peter Bachert2, Mark E. Ladd2, Heinz-Peter Schlemmer1, Moritz Zaiss5, and Alexander Radbruch1

1Radiology, German Cancer Research Center, Heidelberg, Germany, 2Medical Physics in Radiology, German Cancer Research Center, Heidelberg, Germany, 3Neurology, University Hospital Heidelberg, Heidelberg, 4Neuroradiology, University Hospital Heidelberg, Heidelberg, 5Max-Planck-Institut Tübingen, Tübingen, Germany

Glucose is the main energy source of cancer cells to proliferate and survive. Recently, promising results to assess changes in cellular metabolism using natural unlabeled D-glucose as biodegradable MRI contrast agent, have been reported employing Chemical Exchange Saturation Transfer (CEST) and Chemical Exchange sensitive Spin-Lock (CESL) imaging. In this work, the CESL-based dynamic glucose enhanced (DGE) contrast was investigated in healthy volunteers and a homogenous cohort of newly diagnosed untreated glioblastoma patients at 7 Tesla. DGE MRI allowed for sensitive visualization of physiological glucose uptake in the healthy human brain and pathophysiologically increased glucose enhancement of brain tumors.

982
Plasma 6
3D printed Breast DCE-MRI phantom to mimic structure and pharmacokinetics
Nithin N Vajuvalli1, Chethan Kumar M1, Amaresha Shridhar Konar1,2, Shivaprasad Ashok Chikop1, Darshan Shivaramu Keelara1, Ashwini Kumnoor1, Ramesh Venkatesan2, and Sairam Geethanath1

1Medical Imaging Research Centre, Dayananda Sagar Institution, Bangalore, India, 2Wipro GE healthcare, Bangalore, India

DCE MRI plays a critical role in routine clinical breast examination. Current work focuses on the development of Breast DCE MRI phantom using a 3D printer to mimic poor and well perfused regions. The phantom developed was controlled through user entered Ktrans values entered in a GUI which interfaced with a peristaltic pump to control flow rates. The Kep parameters was controlled through the 3D model geometry. Prospective MR images of the phantom were acquired on a 1.5T scanner using the TRICKS sequence; and pharmacokinetic maps based on Tofts model were computed and quantified.

983
Plasma 7
Recurrent Neural Network on DCE-MRI in Prostate Cancer
Xia Li1, Vivek Vaidya2, Sandeep Gupta1, Rakesh Mullick2, Oguz Akin3, and Dattesh Shanbhag2

1GE Global Research Center, Niskayuna, NY, United States, 2GE Global Research Center, Bengaluru, India, 3Memorial Sloan-Kettering Cancer Center, NY, United States

DCE-MRI has become an important protocol in mpMRI analysis of prostate cancer and it has been quantified typically using pharmaco-kinetic modelling and the estimated parameters are then used with other approaches (machine learning or deep learning (DL)) to characterize/discriminate tumor tissue against healthy tissue. However, it is not clear if applying DL to the DCE-MRI time series directly is beneficial for prostate cancer detection. Hence, we propose a DL based method to differentiate prostate tumor from healthy tissues at the voxel level using raw arbitrary signal DCE time-series itself. Overall, DL based tumor characterization provided similar detectability for prostate tumor when compared to Ktrans and ve maps. We also evaluated differences in tumor characterization when contrast agent concentration time-curves were used instead of arbitrary signal curves and found them to provide similar detectability. 

984
Plasma 8
In vivo assessment of tumour invasion of the visual pathway in optic pathway glioma patients using multi-shell diffusion tensor MRI
Patrick W Hales1, Victoria Smith2, Patricia O'Hare3, Kshitij Mankad4, Felice d'Arco4, Jessica Cooper4, Ramneek Kaur1, Kim Phipps3, Darren Hargrave3, and Christopher A Clark1

1Developmental Imaging & Biophysics Section, University College London, London, United Kingdom, 2Ophthalmology Department, Great Ormond Street Children’s Hospital, London, United Kingdom, 3Haematology and Oncology Department, Great Ormond Street Children’s Hospital, London, United Kingdom, 4Radiology Department, Great Ormond Street Children’s Hospital, London, United Kingdom

Optic pathway glioma (OPG) is a childhood tumour of the visual pathway. Some OPG patients remain stable, whereas others experience rapid visual decline; however, conventional MRI cannot stratify these patients. We used multi-shell DTI to measure tumour invasion of the optic pathway in 23 OPG patients, in conjunction with visual assessment. A strong correlation was found between fractional anisotropy in the optic nerves and optic radiations, and visual acuity (p=0.00092 and p=0.008 respectively). Our study demonstrates that multi-shell diffusion-MRI offers increased sensitivity over conventional MRI in detecting white matter integrity and function in the visual pathway of OPG patients.

985
Plasma 9
Pipeline for longitudinal assessment of patient-derived mouse xenografts using 3D magnetization transfer-weighted MRI
Kimberly L. Desmond1, David Bakhshinyan2, Maleeha Qazi2, Parvez Vora2, Chirayu Chokshi2, Sheila K. Singh2, and Nicholas A. Bock1

1Psychology, Neuroscience and Behaviour, McMaster University, Hamilton, ON, Canada, 2McMaster Stem Cell and Cancer Research Institute, McMaster University, Hamilton, ON, Canada

A pipeline was developed, driven by 3D magnetization transfer-weighted images acquired without contrast agent, to automatically assess mouse models of patient-derived tumours against an atlas of control NOD-SCID mice, for the purposes of longitudinal, high-throughput screening of mice for response to cancer therapy and recurrence.  

986
Plasma 10
Tumor Interstitial Fluid Pressure and Hydraulic Conductivity Estimates by DCE-MRI in a Rat Model of Cerebral Tumor
Rasha Elmghirbi1,2, Nagaraja N. Tavarekere3, Stephen L. Brown4, Swayamprava Panda1, Kelly A. Keenan3, Glauber Cabral1, Hassan Bagher-Ebadian2,4, and James R. Ewing1,2

1Neurology, Henry Ford Hospital, Detroit, MI, United States, 2Physics, Oakland University, Rochester Hills, MI, United States, 3Neurosurgery, Henry Ford Hospital, Detroit, MI, United States, 4Radiation Oncology, Henry Ford Hospital, Detroit, MI, United States

An elevated tumor interstitial fluid pressure (TIFP) is a critical element for assessing therapeutic response. This study demonstrates the use of DCE-MRI to estimate TIFP, and validates that estimate by an invasive method in a rat glioblastoma model, with and without treatment interventions. Significant positive correlations between MRI-derived TIFP estimates and invasive measures of TIFP were found in all groups (e.g., for untreated group, R2=0.76, p<0.0001). These findings validate an MRI-estimated TIFP as a noninvasive measure of TIFP in embedded cerebral tumors, and suggest that it may be a useful tool in assessing tumor response to therapy.

987
Plasma 11
A preclinical MRI study investigating the impact of the local microenvironment on the progression of diffuse intrinsic pontine glioma in patient-derived xenografts
Mariama Fofana1, Jessica KR Boult1, Maria Vinci1, Valeria Molinari1, Kathryn Taylor1, Sergey Popov1, Alan Mackay1, Chris Jones1, and Simon P Robinson1

1The Institute of Cancer Research, London, United Kingdom

Diffuse intrinsic pontine glioma (DIPG) is a devastating childhood brain tumour with very poor outcome. The local brain microenvironment appears to play an important role in the tumourigenesis of DIPG, and is currently underinvestigated. Infratentorial and hemispheric tumour growth patterns of orthotopic DIPG xenografts were assessed longitudinally by anatomical MRI, and confirmed by immunohistochemical analysis. ADC, T1 and T2 were higher in infratentorial tumours than hemispheric tumours, corresponding to a higher degree of tumour-associated oedema observed histologically.

988
Plasma 12
Multi-parametric MRI Radiomics for Pre-treatment Prediction of the Progression-Free Survival in Advanced Nasopharyngeal Carcinoma
Bin Zhang1

1Guangdong General hospital, Guangzhou, People's Republic of China

To our knowledge, this is the first MRI-based radiomics study to predicting survival of tumor. The results of our study show that multiparametric MRI-based radiomics nomogram significantly improves the 7th edition of AJCC TNM staging system and clinical data in predicting individualized progression-free survival (PFS) in advanced NPC (stage III-IVb). In fact, the radiomics nomogram built in our study could integrate all prognostic biomarkers/signatures that have been published in this area to improve its predictive performance. Besides, for the first time, our radiomics heatmaps showed positive associations between radiomics signature features with overall stage, T-stage and negative associations between radiomics signature features with N-stage. Our radiomics study provides some different insights into the mechanism of hematogenous and lymphatic metastasis of NPC. 

989
Plasma 13
MR Elastography and Perfusion MRI for the Early Assessment of Treatment Response in Soft Tissue Sarcomas
Kay Pepin1, Roger Grimm2, Soudabeh Kargar3, Sarah James1, Matthew Howe2, Karen Fritchie4, Matthew Frick2, Doris Wenger2, Richard Ehman2, Nadia Laack1, Michael Herman1, and Deanna Pafundi1

1Radiation Oncology, Mayo Clinic, Rochester, MN, United States, 2Radiology, Mayo Clinic, Rochester, MN, United States, 3Mayo Graduate School, Mayo Clinic, Rochester, MN, United States, 4Pathology, Mayo Clinic, Rochester, MN, United States

Advanced imaging is a critical component in the development of patient-specific and novel treatment strategies, and the non-invasive evaluation of early response in sarcomas. Our central hypothesis is that changes in sarcoma stiffness quantified with MRE and perfusion with DCE-MRI throughout therapy can predict response. Soft tissue sarcomas are a rare malignancy arising in a wide range of anatomic locations.  Anatomy-specific imaging protocols were developed to evaluate soft tissue sarcomas in 9 patients. In 3 patients, we investigated the feasibility to assess response to radiation therapy and observed a decrease in parameters related to tumor stiffness and perfusion metrics.

990
Plasma 14
Quantitative Imaging for Radiotherapy on an MR-Linac Scanner
Folkert Koetsveld1, Leon C. ter Beek2, Petra J. van Houdt1, Laurens D. van Buuren1, and Uulke A. van der Heide1

1Radiotherapy, Netherlands Cancer Institute, Amsterdam, Netherlands, 2Radiology, Netherlands Cancer Institute, Amsterdam, Netherlands

The MR-Linac integrates and MR-scanner with a radiotherapy treatment machine. Patients undergoing radiotherapy treatment will be imaged daily on the MR-Linac. We investigated the suitability of the MR-Linac as a platform for quantitative imaging. Daily quantitative imaging can be used for imaging biomarker discovery, and give information on tumor treatment response. We did phantom studies of four quantitative MRI techniques: T2 mapping, dynamic contrast enhanced imaging, T1 mapping and diffusion weighted imaging to determine the accuracy of these techniques on the MR-Linac. We tested the repeatability of T2 mapping on a volunteer.

991
Plasma 15
Support vector machine for breast cancer classification using DWI histogram features: preliminary study
Igor Vidić1, Liv Egnell1, Jose R. Teruel2, Torill E. Sjøbakk3, Neil P. Jerome3, Agnes Østlie4, Hans E. Fjøsne5,6, Tone F. Bathen3, and Pål Erik Goa1

1Department of Physics, Norwegian University of Science and Technology (NTNU), Trondheim, Norway, 2Department of Radiology, University of California, La Jolla, CA, United States, 3Department of Circulation and Medical Imaging, Norwegian University of Science and Technology (NTNU), Trondheim, Norway, 4Clinic of Radiology and Nuclear Medicine, St. Olavs University Hospital, Trondheim, Norway, 5Department of Cancer Research and Molecular Medicine, Norwegian University of Science and Technology (NTNU), Trondheim, Norway, 6Department of Surgery, St. Olavs University Hospital, Trondheim, Norway

In this work we use the machine learning method support vector machine (SVM) to classify malignant and benign tumors, as well as ER+HER2- and ER+HER2+. As feature we use histogram properties of DWI-models (RED, ADC, IVIM) parameters as features. Our study showed that SVM classifiers using combinations of features from different models have predictive power in both analyses, also it performed better than SVM using combination of parameters obtained only from one of the models. The results are encouraging because SVM with DWI parameters can potentialy hinder unnecessary biopsies. 


Electronic Power Pitch Poster

Poster: Contrast Mechanisms: New Horizons

Exhibition Hall Thursday 9:15 - 10:15

992
Plasma 16
On the decay of SSFP configurations
Damien Nguyen1,2, Rahel Heule1,2, Carl Ganter3, and Oliver Bieri1,2

1Radiological Physics, University of Basel Hospital, Basel, Switzerland, 2Department of Biomedical Engineering, University of Basel, Basel, Switzerland, 3Department of Diagnostic Radiology, Klinikum rechts der Isar, Technical University Munich, Munich, Germany

In this work, we explore the decay of negative and positive steady state configurations as a mean to assess the tissue microstructure. Steady state configurations are retrieved up to a high order from an exhaustive sampling of the frequency response profile of low-angle balanced SSFP scans. Subsequently, the decay of configurations (termed DECO) is analyzed using a single-pole matrix pencil analysis yielding positive and negative DECO images. Any asymmetry in the configuration decay is directly linked to asymmetric frequency content within a voxel and is captured in the DECO difference image.

993
Plasma 17
Asymmetries of the balanced SSFP profile allow to probe microstructure anisotropy at 9.4 Tesla
Philipp Ehses1,2, Mario Gilberto Báez-Yánez2,3, Michael Erb1, and Klaus Scheffler1,2

1Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany, 2Dept. of High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Tübingen, Germany, 3Graduate Training Centre of Neuroscience, University of Tübingen, Tübingen, Germany

The bSSFP signal profile exhibits tissue-dependent asymmetries that can be used as a novel contrast mechanism and have been hypothesized to relate to the tissue microenvironment. In this work, we investigate this effect at ultra high-field using phase-cycled bSSFP at an isotropic resolution of 1.2 mm. As in the original publication, we also observe strong asymmetries in white matter and a comparison to DTI data reveals that the largest asymmetries occur in white matter tracts oriented orthogonal to the main magnetic field.

994
Plasma 18
Quantitative modeling of exchange in bSSFPX
Shu Zhang1, Robert E Lenkinski1,2, and Elena Vinogradov1,2

1Department of Radiology, UT Southwestern Medical Center, Dallas, TX, United States, 2Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX, United States

bSSFP was shown to be sensitive to exchange and is explored as an alternative way for CEST/T experiments (the bSSFPX method). In this abstract, an analytical solution is derived for the magnetization behavior in the bSSFPX. The solution describes the transient signal fluctuations for short saturation times. The solution is verified by comparing it to full, step-wise computation of Bloch-McConnell Equations. Overall, this solution is in good agreement with Bloch-McConnell Equations and follows the transient signal oscillations well. Work is in progress to use this solution to quantify exchange rates experimentally.

995
Plasma 19
Spin-lock imaging of exogenous exchange-based contrast agents to assess tissue pH
Zhongliang Zu1, Hua Li1, Xiaoyu Jiang1, and John C Gore1

1Vanderbilt University, Nashville, TN, United States

We measured spin-lock relaxation rates as a function of locking field to quantify tissue pH and the concentration of an exogenous X-ray contrast agent, iohexol, based on chemical exchange effects. Results show that spin-lock imaging can be used to detect exchange-based agents and the effects of tissue acidification.


996
Plasma 20
Quantification of trans-endothelial water exchange and vessel geometry using contrast-enhanced MRI and alterations in a transgenic rat model of Alzheimer’s disease
Ben Dickie1, Hervé Boutin1,2, Jose Ulloa3,4, Laura M Parkes1, and Geoff JM Parker3

1Division of Neuroscience and Experimental Psychology, University of Manchester, Manchester, United Kingdom, 2The Wolfson Molecular Imaging Centre, University of Manchester, Manchester, United Kingdom, 3Division of Informatics, Imaging and Data Sciences, University of Manchester, Manchester, United Kingdom, 4Bioxydyn, Manchester

MRI measurements of cerebrovascular function and structure are important for understanding neurodegenerative disease mechanisms. In this study, a novel contrast-enhanced multi-flip angle multi-echo (MFAME) MRI technique capable of simultaneously quantifying vessel permeability surface area product to water (PSw), blood water population fraction (pb), and contrast agent r2* is presented, and applied to a transgenic rat model of Alzheimer’s disease (TgF344-AD). Transgenic rats exhibit higher pb and lower PSw in the hippocampus compared to wild-types, suggesting MFAME MRI may be sensitive to regional pathologic microvascular alterations in this model. 

997
Plasma 21
CEST-weighted MRI at 21.1 T: application to glioma and ischemic rat model
Tangi Roussel1,2, Jens T. Rosenberg3, Samuel C. Grant 3,4, and Lucio Frydman2

1NeuroSpin, Commisariat à l'Energie Atomique et aux Energies Alternatives, Gif-sur-Yvette, France, 2Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel, 3National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL, United States, 4Department of Chemical & Biomedical Engineering, The Florida State University, Tallahassee, FL, United States

This study explores and demonstrates the opportunities opened by ultrahigh fields for in vivo CEST-weighted imaging. CEST-weighted fast spin-echo imaging was performed on two neurological models: hypoxic ischemic and glioblastoma. A remarkably strong CEST contrast (≈15%) was observed for the tumors at 3.32 ppm originating mainly from an APT increase and a strong decrease in NOE and MT. Ischemic lesions were still more robustly detected with standard T2-weighted images than with CEST. Potential explanations and dependence with high magnetic field are discussed.

998
Plasma 22
Offset-Saturation-Induced (osi-) Variations in Multiexponential T2 at 16.4T: A New Dimension for Probing White Matter Contrast
Teresa Serradas Duarte1 and Noam Shemesh1

1Champalimaud Neuroscience Programme, Champalimaud Centre for the Unknown, Lisbon, Portugal

Whether Magnetization Transfer could affect Multiexponential T2 (MET2) Relaxometry remains poorly explored. Here, the effects of irradiation at different offset frequencies on the MET2 components were evaluated as novel contrast mechanisms for white matter in the rat spinal cord at 16.4T. MET2 coefficients were found to shift with off-resonance saturation, showing unique tract-specific signatures across the irradiation frequency. Offset-saturation-induced (osi-) MET2 Relaxometry maps show strong contrasts between microstructurally-distinct rat spinal cord tracts. The potential of exploiting the osi-MET2 shift phenomenon to increase white matter contrast is discussed.

999
Plasma 23
Magneto-Caloric Materials as Tunable and Switchable Labels for MRI
Mladen Barbic1, Tim D Harris1, Stephen Dodd2, H Douglas Morris3, Alan P Koretsky2, Barbara Marcheschi4, Alan Huston4, and Neil R Dilley5

1Applied Physics and Instrumentation Group, HHMI-Janelia Research Campus, Ashburn, VA, United States, 2Laboratory of Functional and Molecular Imaging, NIH/NINDS, Bethesda, MD, United States, 3NIH Mouse Imaging Facility, NIH/NINDS, Bethesda, MD, United States, 4Code 5611, Optical Sciences Division, Naval Research Laboratory, Washington, DC, United States, 5Quantum Design, Inc., San Diego, CA, United States

We present the case for the use of magneto-caloric materials as tunable and switchable labels for MRI. Sharp magnetic phase transitions these materials have at typical physiological temperatures and in the presence of the large DC magnetic field values associated with MRI machines make them uniquely suitable for the development of novel MRI contrast agents. We present physical and MRI measurements of a prototypical magneto-caloric material Iron-Rhodium (FeRh) that clearly demonstrate the MR image contrast changes due to the temperature tunable magnetic state of the material in the MRI compatible magnetic field range and physiologically relevant temperature range.

1000
Plasma 24
The T1-Dispersion Curve as a Biomarker of Colorectal Cancer
Vasileios Zampetoulas1, Lionel M. Broche1, Graeme I. Murray2, and David J. Lurie1

1Aberdeen Biomedical Imaging Centre, School of Medicine, Medical Sciences & Nutrition, University of Aberdeen, AB25 2ZD, Scotland, United Kingdom, 2Department of Pathology, University of Aberdeen, AB25 2ZD, Scotland, United Kingdom

A graph of T1 versus applied magnetic field, obtained via Fast Field-Cycling (FFC) NMR relaxometry, can be used as a diagnostic tool thanks to the information it provides about molecular dynamics. In this work, FFC NMR relaxometry, extended to magnetic fields below 17 μT, was used to investigate new biomarkers of colorectal cancer. The acquired results indicated that there were significant differences in the molecular motions with correlation times 0.1-10 ms and 0.5–1.4 μs between the healthy and cancer tissues examined, showing great potential for diagnosis, staging and monitoring response to treatment.

1001
Plasma 25
Detecting regional changes in brain tissue quantitative T1 values due to hydration status
Sofia Chavez1,2

1Centre for Addiction and Mental Health (CAMH), Toronto, ON, Canada, 2Psychiatry, University of Toronto, Toronto, ON, Canada

Volumetric/morphometric changes in brain structures are often investigated as markers for disease or drug-induced effects. Brain tissue has been shown to shrink during mild dehydration which is not typically controlled for in MRI studies thus potentially confounding the results. Quantitative T1 is expected to change in response to changes in water content of tissue. Here, we show for the first time, that T1 maps, generated as we suggest, can capture regional water shifts that result from changes in hydration status. These can be used to control for water shifts in volumetric/morphometric studies and may aid in the interpretation of results.


1002
Plasma 26
In vivo whole-blood $$$T_2$$$ versus $$$HbO_2$$$ calibration by modulating blood oxygenation level in the femoral vein through intermittent cuff occlusion
Michael C Langham1, Ana E Rodríguez-Soto1, Nadav Schwartz2, and Felix W Wehrli1

1Radiology, University of Pennsylvania, Philadelphia, PA, United States, 2Obstetrics and Gynecology, University of Pennsylvania, Philadelphia, PA, United States

The relationship between whole-blood T2 and blood hemoglobin oxygen saturation (HbO2) can be modeled as $$${1\over T_{2b}}={1\over T_{2o}}+K(1-HbO_2)^2$$$, where K and T2o are determined empirically in vitro. The feasibility of estimating K and T2o in vivo is investigated with T2-prepared bSSFP at 1.5T in the superficial femoral vein (SFV) with intermittent cuff occlusion. In this manner a range of HbO2 were achieved allowing quantification of venous oxygen saturation via MR susceptometry, a method that had been validated rigorously against blood gas analysis. Initial result (K=19.6Hz, T2o=185ms) is lower than the literature value (24.6Hz, 254ms) but not unexpected because transient bSSFP signal is acquired while disturbing the T2-prepared magnetization.

1003
Plasma 27
Visualizing local mechanical properties of agar phantoms and meningioma patients using magnetic resonance rheology
Sebastian Theilenberg1, Jakob Bindl1, Anna-Lisa Kofahl1, Carsten Urbach1, and Karl Maier1

1Helmholtz-Institut für Strahlen- und Kernphysik, University of Bonn, Bonn, Germany

Magnetic resonance rheology is a novel method to create an imaging contrast based on the mechanical properties of brain tissue. It is based on a short fall of the head that creates a broadband excitation of the tissue. The resulting deflections of the tissue elements are depicted using motion sensitive phase imaging. This contribution presents measurements on agar phantoms as well as four meningioma patients to show the feasibility of the method to depict local alterations of the mechanical properties of the investigated material.

1004
Plasma 28
Early Cancer Detection Using Paramagnetic Liposome by a Novel Contrast Mechanism with Active-feedback Magnetic Resonance Imaging
Sayoni Ray1, Chao-Hsiung Hsu2, Zhao Li1, Fang-Chu Lin1, Ying-Chih Lin2, and Yung-Ya Lin1

1DEPARTMENT OF CHEMISTRY AND BIOCHEMISTRY, University Of California, Los Angeles, Los Angeles, CA, United States, 2Department of Chemistry, National Taiwan University, Taiwan

The detection of early tumors requires creating the contrast between healthy and tumor tissues that share a common morphology, making it difficult to distinguish them by relaxation-based MRI technique. Here we have exploited the small magnetic differences between the healthy and tumor tissues to develop a detection technique of early tumors using theranostic nanoparticle paramagnetic (Gd) liposome along with continuous wave (CW) irradiation in the presence of the feedback magnetic field from an active-feedback electronic device for in vivo subcutaneous glioblastoma multiforme mouse models and obtained significantly superior contrast compared to the conventional MRI technique, in agreement with spin-dynamics simulations. 

1005
Plasma 29
Analysis of magnetohydrodynamic effects in current injection induced magnetic flux density images at very high magnetic fields
Atul S Minhas1, Munish Chauhan2, and Rosalind J Sadleir2

1Centre for Pre-clinical Imaging, Department of Cellular and Molecular Physiology, University of Liverpool, Liverpool, United Kingdom, 2School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ, United States

Magnetic resonance imaging based electrical conductivity imaging of biological tissues could be highly challenging at magnetic fields of the order of 18.8T. We could see significant magnetohydrodynamic (MHD) effects in low viscosity materials at such fields. In this study, we investigated these effects using saline and agarose phantoms and explained the MHD mechanism using a fluid flow model coupled with electromagnetic field equations. Experimental and simulation results showed a correlation between the higher magnetic field and velocity. This relation changed from exponential to linear as the viscosity of material increased. The velocity was negligible for highly viscous materials such as agarose.

1006
Plasma 30
Quadrupolar jump-and-return sequence for sodium knee MRI at 7 tesla
Jae Seung Lee1, Ding Xia1, and Ravinder Regatte1

1Radiology, New York University, New York, NY, United States

Glycosaminoglycans (GAGs) is an important biomarker for the diseases related to the degradation of cartilage tissues. The GAG content in cartilage tissue is known to be well correlated with the sodium concentration. In addition, the collagenous extracellular matrices of cartilage tissues provide sodium ions with ordered environments. Recently, the so-called quadrupolar jump-and-return (QJR) sequence has been developed, which can selectively detect sodium ions in ordered environments. In this work, we demonstrate the feasibility of the QJR sequence for in vivo knee MRI by assessing its performance on the contrast modification to cartilage tissues and fluid.


Electronic Power Pitch Poster

Poster: Cutting Edge Diffusion

Exhibition Hall Thursday 14:00 - 15:00

1082
Plasma 1
Approaching free intracellular diffusion by diffusion-weighted MRS at ultra-short time scales: initial results in the rodent brain using a 1.5 T/m gradient
Clémence Ligneul1, Marco Palombo1, Julien Flament2, and Julien Valette1

1Molecular Imaging Research Center (MIRCen), Commissariat à l'Energie Atomique, Fontenay-aux-Roses, France, 2UMS 27, INSERM, Fontenay-aux-Roses, France

At ultra-short time scales, intracellular metabolites are expected to experience less restriction, so that their apparent diffusion coefficient (ADC) as measured by diffusion-weighted MRS should approach the free intracellular diffusivity in a manner which depends on small microstructural features. In this work we use a unique gradient insert capable of reaching 1.5 T/m to measure metabolite ADC in the rat brain up to 665 Hz using oscillating gradients (corresponding to 0.21-ms diffusion time in the Mitra limit), in order to approach and estimate free intracellular diffusion.

1083
Plasma 2
Accurate estimation of intra-axonal diffusivity and anisotropy of NAA in humans at 7T
Henrik Lundell1, Carson Ingo2, Tim Bjørn Dyrby1,3, and Itamar Ronen4

1Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre, Copenhagen, Denmark, 2Department of Physical Therapy and Human Movement Sciences, Northwestern University, Chicago, IL, United States, 3Department of Applied Mathematics and Computer Science, Technical University of Denmark, Kongens Lyngby, Denmark, 4C. J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, Denmark

Diffusion weighted spectroscopy offers a unique probe for tissue microstructure and recent studies demonstrate NAA diffusivity as an independent marker of axonal health. In this study we address the problem of macroscopic dispersion of fiber directions and suggest the use of high angular gradient resolution and powder averaging as an experimentally inexpensive and accurate way to solve this problem. We explore the limits of this approach in simulations and in experiments on humans at 7T.


1084
Plasma 3
Glutamate diffusion at high b-values in the rat brain in vivo under light and deep anesthesia conditions
Xi Chen1, Siddartha Moktan Tamang1, Fei Du1, and Dost Ongur1

1McLean Hospital, Belmont, MA, United States

Magnetic resonance techniques are developed to measure brain glutamate (Glu) concentrations but still not able to detect synaptic Glu release. In the currently study, in vivo diffusion-weighted MRS using low to very high b-values was performed on rat brain prefrontal cortex under both light and deep anesthesia conditions. Significant Glu diffusion and concentration changes were observed under different anesthesia levels in the absence of similar changes in NAA or creatine. The slower diffusion and lower concentration under deep anesthesia may reflect more Glu packed into synaptic vesicles with reduced mobility and NMR visibility.

1085
Plasma 4
Bias in the apparent exchange rate measurements: insight from numerical simulations
Patricia Ulloa1, Vincent Methot1, and Martin A. Koch1

1University of Lübeck, Lübeck, Germany

Using double diffusion encoding it is possible to acquire microstructural and water exchange information. Here, simulations are used to study how restriction effects influence apparent exchange measurements. The simulations indicate that at the chosen experimental parameters the restriction effect can be considerable for large pores and small mixing times, τm. In typical exchange rate experiments using clinical MR systems with τm > 40 ms, the restriction effect can probably be neglected if pores are small.

1086
Plasma 5
Microscopic anisotropy with spectrally modulated q-space trajectory encoding
Henrik Lundell1, Markus Nilsson2, Tim Bjørn Dyrby1,3, Geoff JM Parker4,5, Penny L Hubbard Cristinacce4, Fenglei Zhou4, Daniel Topgaard6, and Samo Lasic1,7

1Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre, Hvidovre, Denmark, 2Clinical Sciences Lund, Radiology, Lund University, Lund, Sweden, 34. Department of Applied Mathematics and Computer Science, Technical University of Denmark, Kongens Lyngby, Denmark, 4Centre for Imaging Sciences, The University of Manchester, Manchester, United Kingdom, 5Bioxydyn Limited, Manchester, United Kingdom, 6Division of Physical Chemistry, Department of Chemistry, Lund University, Lund, Sweden, 7CR Development AB, Lund, Sweden

Multi-dimensional diffusion encoding can, in contrast to conventional diffusion encoding, disambiguate between isotropic and anisotropic diffusional variance in multicompartment systems. This is done by varying the shape of the encoding tensor, i.e. going from measuring one projection of the diffusion tensors to measuring the trace of the diffusion tensors. Additional morphological features, such as the sizes of cells, are reflected in the diffusion spectrum. In this study we combine encoding tensors with varying spectral content and shape. This augmented protocol demonstrates distinctively different levels of microscopic fractional anisotropy (µFA) and time-dependent diffusion in phantoms and in white matter, cerebral cortex, and cerebellar cortex in a fixed monkey brain.

1087
Plasma 6
Can we detect the effect of spines, leaflets and beads on the diffusion of brain intracellular metabolites? A confrontation between high b-values and high-frequencies diffusion-weighted MRS in the mouse brain in vivo.
Marco Palombo1, Clemence Ligneul1, Edwin Hernandez-Garzon1, and Julien Valette1

1Molecular Imaging Research Center (MIRCen), Commissariat à l'Energie Atomique, Fontenay-aux-Roses, France

Prior models used to clarify which aspects of tissue microstructure mostly affect intracellular diffusion and corresponding diffusion-weighted magnetic resonance signal have focused on relatively simple geometrical descriptions of the cellular microenvironment (spheres, randomly oriented cylinders, etc...), neglecting finer morphological details which may have an important role. Neuritis may exhibit beading; some types of neurons present high density of spines; and astrocytes and macroglial cells processes present leaflets, which may all slow impact the diffusion process. Here we use numerical simulations to interpret metabolites diffusion-weighted MRS data in the mouse brain in terms of such fine secondary structures.

1088
Plasma 7
Diffusion MRI of axonal degeneration in areas of fiber crossing: Histological correspondence.
Luis Concha1, Jorge Larriva-Sahd1, Gilberto Rojas-Vite1, Ramsés Noguez-Imm1, Ricardo Coronado-Leija2, Alonso Ramírez-Manzanares2, and José Luis Marroquín2

1Institute of Neurobiology, Universidad Nacional Autonoma de Mexico, Queretaro, Mexico, 2Computer Science, Centro de Investigación en Matemáticas, Guanajuato, Mexico

The tensor model has been widely used to infer characteristics of white matter through diffusion MRI. Unfortunately, this model does not provide reliable information about crossing fiber regions. Several models have been proposed that seem to overcome the limitations of the tensor. However, biological interpretations of such models are limited by the lack of histological conformation. Using an animal model of axonal degeneration, we compare histology to data derived from two approaches (CSD and multi-tensor), in an effort to provide validation of metrics that can bring substantial and clinically useful information about crossing fiber regions.

1089
Plasma 8
Diffusion anisotropy in breast cancer tissue corresponds to spatial patterns of collagen alignment from structure tensor analysis of histology
Colleen Bailey1, Francesco Grussu2, Bernard Siow3,4, Thomy Mertzanidou1, John H Hipwell1, Julie Owen5, Patrycja Gazinska5, Sarah E Pinder5, Daniel C Alexander1, David J Hawkes1, and Eleftheria Panagiotaki1

1Centre for Medical Image Computing, University College London, London, United Kingdom, 2Institute of Neurology, University College London, London, United Kingdom, 3Centre for Advianced Biomedical Imaging, University College London, London, United Kingdom, 4Imaging, Francis Crick Insitute, London, United Kingdom, 5Breast Research Pathology, King's College London and Guy's Hospital, London, United Kingdom

Directional and anisotropy measures from a diffusion model composed of VERDICT compartments were compared with directional and anisotropy measures from structure tensor analysis of registered histology images. A significant positive correlation was found between the direction of the Zeppelin component of the diffusion model (assumed to represent the extracellular space) and the predominant direction of the structure tensor from the stroma, where the primary feature is aligned collagen. The correlation of anisotropy measures was weak, which may be due to difficulties in detecting alignment in regions with densely-packed collagen, which have nearly uniform intensity on H&E staining.

1090
Plasma 9
A 3D electron microscopy segmentation pipeline for hyper-realistic diffusion simulations
Michiel Kleinnijenhuis1, Errin Johnson2, Jeroen Mollink1,3, Saad Jbabdi1, and Karla Miller1

1Oxford Centre for Functional MRI of the Brain, University of Oxford, Oxford, United Kingdom, 2Sir William Dunn School of Pathology, University of Oxford, Oxford, United Kingdom, 3Department of Anatomy, Donders Institute for Brain, Cognition & Behaviour, Radboud University Medical Center, Nijmegen, Netherlands

Simulations of the diffusion signal can shed light on how the MR signal is generated from particular tissue microstructure. In our approach we use microscopy data to generate a realistic ground truth for investigating diffusion properties. We have developed a method to automatically segment large volumes of 3D electron microscopy data into individual axons for diffusion simulations. From these segmentations, we can also derive benchmark tissue microstructure characteristics such as axonal diameter, g-ratio and other compartment properties.

1091
Plasma 10
Rotationally invariant mapping of microstructural and orientational neuronal tissue parameters in human brain
Dmitry S Novikov1, Jelle Veraart1, Ileana O Jelescu1, and Els Fieremans1

1Radiology, NYU School of Medicine, New York, NY, United States

We develop a general framework for estimating orientational and microstructural parameters of neurites. By employing a set of rotational invariants, we analytically reveal the nontrivial topology of the parameter estimation landscape, showing that multiple branches of parameters describe the measurement almost equally well, with only one of them corresponding to the biophysical reality. A comprehensive acquisition shows that the branch choice differs for white and for gray matter. We reveal hidden degeneracies in MRI parameter estimation for neuronal tissue, provide microstructural and orientational maps in the whole brain without constraints or priors, and assess commonly used parameter constraints. 

1092
Plasma 11
Isotropic Diffusion Weighted MRI (IDWI) – a novel, efficient clinical method for quantifying orientationally-averaged features of water diffusion in tissues
Alexandru Vlad Avram1, Joelle Sarlls2, Elizabeth Hutchinson3, and Peter Basser3

1NIBIB, National Institutes of Health, Bethesda, MD, United States, 2NINDS, National Institutes of Health, Bethesda, MD, United States, 3NICHD, National Institutes of Health, Bethesda, MD, United States

We propose a novel, efficient diffusion method, called isotropic diffusion weighted MRI (IDWI), for measuring orientationally-averaged properties of tissue water diffusion, free from modulations due to anisotropy. Using efficient diffusion gradient sampling schemes, IDWI rapidly and accurately quantifies the mean apparent diffusion coefficient (mADC) over a wide range of b-values, along with other important rotation-invariant intrinsic microstructural parameters, such as the mean t-kurtosis. The ability to efficiently and effectively remove modulations due to anisotropy in images with high-b values may improve existing diffusion MRI techniques and spur the development and clinical translation of new methods with improved biological specificity.

1093
Plasma 12
Diffusion MRI differentiated acute inflammation from axonal injury but missed axonal loss
Tsen-Hsuan (Abby) Lin1, Michael Wallendorf2, Peng Sun1, and Sheng-Kwei Song1,3,4

1Radiology, Washington University School of Medicine, St. Louis, MO, United States, 2Biostatistics, Washington University School of Medicine, St. Louis, MO, United States, 3The Hope Center for Neurological Disorders, Washington University School of Medicine, St. Louis, MO, United States, 4Biomedical Engineering, Washington University in St. Louis, St. Louis, MO

Diffusion MRI with higher b-values and custom-designed diffusion schemes are critical to identify subtle and coexisting pathology in CNS. In the current study, we employed single-axial high-b diffusion-weighted imaging (DWI) and low-b diffusion basis spectrum imaging (DBSI) to assess mouse optic nerve crush acutely. The results suggested coexisting CNS pathology affected apparent diffusion coefficient (ADC), and low-b DBSI was able to reflect axon and myelin integrity as well as inflammatory edema and cellularity even before histological detection. DBSI-detected axon volume correlated with axonal loss negatively, suggesting cytotoxic-edema-associated axonal swelling might mask axonal loss acutely.

1094
Plasma 13
Three-Dimensional Multiplexed Sensitivity Encoding and Reconstruction (3D-MUSER): 3D Phase Correction for 3D Multi-shot DWI
Hing-Chiu Chang1, Edward S. Hui1,2, Xiaoxi Liu1, Pui-Wai Chiu1, and Nan-kuei Chen3,4

1Department of Diagnostic Radiology, The University of Hong Kong, Hong Kong, Hong Kong, 2The State Key Laboratory of Brain and Cognitive Sciences, The University of Hong Kong, Hong Kong, 3Department of Biomedical Engineering, University of Arizona, Tucson, AZ, United States, 4Brain Imaging and Analysis Center, Duke University Medical Center, Durham, NC, United States

3D interleaved DW-EPI with 2D multiplexed sensitivity encoding has been shown useful in achieving submillimeter DTI. Similar to other 3D DTI techniques, 2D phase variation is only considered in eliminating aliasing artifacts, thereby limiting feasible slab thickness. 3D phase correction is a potential strategy to significantly improve the image quality and feasible slab thickness of 3D DTI. To enable 3D phase correction, we develop a new reconstruction algorithm, and implement an EVI-based navigator echo for direct 3D phase measurement. Quantitative results show that the proposed algorithm can effectively eliminate aliasing artifacts and signal corruptions due to 3D inter-shot phase variations.

1095
Plasma 14
Visualizing Axonal Damage in Multiple Sclerosis Using Double Diffusion Encoding MRI in a Clinical Setting
Grant Kaijuin Yang1,2, Qiyuan Tian1,2, Christoph Leuze2, Max Wintermark2, and Jennifer McNab2

1Electrical Engineering, Stanford University, Stanford, CA, United States, 2Radiology, Stanford University, Stanford, CA, United States

Double diffusion encoding (DDE) measurements of microscopic anisotropy show promise as a method of assessing neurodegeneration. Unfortunately, DDE has yet to be demonstrated in a clinical setting due to constraints in SNR and scan time.  Here, we used an optimized gradient orientation scheme to show the first DDE measurements of microscopic anisotropy in multiple sclerosis (MS) patients. Five MS patients were scanned using a DDE sequence optimized to run in five minutes. The microscopic anisotropy maps show improved visualization of axonal damage compared to fractional anisotropy (FA) and may provide additional insight into changes in tissue microstructure.  

1096
Plasma 15
Accelerated Diffusion-Sensitized MR Imaging of the Eye and Orbit at 3.0 T and 7.0 T free of Geometric Distortions Using a Combined RARE-EPI Acquisition Technique
Katharina Paul1, Helmar Waiczies2, André Kuehne2, Till Huelnhagen1, Eva Oberacker1, Oliver Stachs3, and Thoralf Niendorf1,2,4

1Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrueck Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany, 2MRI.TOOLS GmbH, Berlin, Germany, 3Department of Ophthalmology, University of Rostock, Rostock, Germany, 4Experimental and Clinical Research Center (ECRC), a joint cooperation between the Charité Medical Faculty and the Max Delbrueck Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany

Diffusion-weighted imaging of the eye and orbit is an emerging MRI application to provide guidance during diagnostic assessment and treatment of ophthalmological diseases. RARE based diffusion-sensitized imaging (ms-RARE) provides images free of geometric distortions. Yet imaging speed, RF power deposition and artifacts by involuntary eye motion remain a concern. Combined acquisition techniques (CAT) merging RARE and EPI within one echo train offer the possibility to shorten acquisition times and relax specific absorption rate constraints. This study examines the applicability of RARE-EPI CAT for diffusion-sensitized imaging of the eye and orbit free of geometric distortions at 3.0 T and 7.0 T.


Electronic Power Pitch Poster

Poster: Emerging Neuroimaging Techniques

Exhibition Hall Thursday 14:00 - 15:00

1097
Plasma 16
Characterization of White Matter Tortuosity using High-Resolution gSlider-SMS Diffusion Imaging
Choukri Mekkaoui1, Marcel P Jackowski2, Kawin Setsompop1, Qiuyun Fan1, Ned A Ohringer1, William J Kostis3, Timothy G Reese1, Alexandra J Golby4, and Susie Y Huang1

1Harvard Medical School - Massachusetts General Hospital, Boston, MA, United States, 2University of São Paulo, São Paulo, Brazil, 3Rutgers Robert Wood Johnson Medical School, New Brunswick, NJ, United States, 4Brigham and Women's Hospital, Harvard Medical, Boston, MA, United States

Conventional tractography excludes acute directional changes. We define these acute changes as tortuosity and use it to characterize gray-white matter boundaries, as well as quantify deformation and remodeling in pathologic states. Five healthy volunteers and a brain tumor patient were scanned using the gSlider-SMS technique. Diffusion data was processed to create 3D contiguous ribbons that characterize tortuosity. Twisting angles of the 3D ribbons were compared within and between subjects, and were visually and statistically consistent. This highly informative tractographic method could be applied to evaluate tumor infiltration and adjacent brain compression, or traumatic brain injury.

1098
Plasma 17
In Vivo Characterization of an Ultrashort-T2 Component in the Brain Reveals a Chemical Shift
Peder Eric Zufall Larson1, Tanguy Boucneau2, Shuyu Tang1, Misung Han1, Peng Cao1, and Roland G Henry3

1Radiology and Biomedical Imaging, University of California - San Francisco, San Francisco, CA, United States, 2Ecole normale supérieure de Cachan, Paris, France, 3Neurology, University of California - San Francisco, San Francisco, CA, United States

A new approach for direct measurements of myelin content is to image an sub-millisecond T2 component in the brain, likely associated with myelin membrane protons .  This study characterized this ultrashort-T2 component across the whole brain using a novel relaxometry approach at ultrashort echo times (UTEs).  This component had an estimated T2* ~ 0.6-1.0 ms at 3T and ~0.2-0.4 ms at 7T, as well as an approximately -3.2 ppm frequency shift from water that has never been measured before in vivo.  This verifies that the ultrashort-T2 component primarily arises from methylene protons, as in the myelin phospholipid membranes.

1099
Plasma 18
Improved Differentiation of Low- and High-Grade Gliomas by APT Contrast Fitted from Z-Spectrum
Jiaxuan Zhang1,2, Rongwen Tain1,3, Xiaohong Joe Zhou1,4, Wenzhen Zhu2, and Kejia Cai1,5

1Center for MR Research, University of Illinois at Chicago, Chicago, IL, United States, 2Department of Radiology, Tongji Hospital, Huazhong University of Science and Technology, Wuhan, People's Republic of China, 3Department of Radiology, University of Illinois at Chicago, Chicago, IL, United States, 4Departments of Radiology, Neurosurgery, and Bioengineering, University of Illinois at Chicago, Chicago, IL, United States, 5Departments of Radiology and Bioengineering, University of Illinois at Chicago, Chicago, IL, United States

Preoperative grading is important for treatment planning in glioma patients. Amide proton transfer (APT) -weighted imaging is helpful in grading since it reflects metabolic changes associated with mobile proteins and peptides. However, the conventional APT based on asymmetrical analysis receives contaminations from semi-solid magnetization transfer asymmetry and nuclear overhauser enhancement effects. Multi-component Z-spectral fitting for the separated quantification of APT can help to remove those contaminations. In this study, we performed such fitting on Z-spectral data from glioma patients. We found that fitted APT provided higher power in differentiating low- and high- grade gliomas compared to the conventional APT quantification.

1100
Plasma 19
3T 1H PRESS (TE 68 ms) reveals elevated cerebral glucose in patients with diabetes mellitus type 2, which is associated with fasting blood glucose
Frank C.G. van Bussel1, Tamar M van Veenendaal1, Miranda T Schram2, Coen D.A. Stehouwer2, Walter H Backes1, and Jacobus F.A. Jansen1

1Radiology, Maastricht University Medical Center, Maastricht, Netherlands, 2Internal Medicine, Maastricht University Medical Center, Maastricht, Netherlands

A standard 1H PRESS sequence, with a TE of 68 ms, acquired at 3T is applied to investigate differences in cerebral glucose concentrations in type 2 diabetes mellitus (T2DM ) compared with controls with normal glucose metabolism. Subjects with T2DM (n=38) display an increased cerebral glucose level compared to controls (n=38). These levels are also associated with two blood glucose measures, fasting blood glucose (FBG) and glycated hemoglobin (HbA1c).

1101
Plasma 20
Towards opto-fMRS:  Ultra high field MRS measurement of T2* changes due to optogenetic stimulation
Jamie Near1,2, Dan Madularu1,2, Jennifer Robinson3, Chathura Kumaragamage4, Axel Mathieu2, Sylvain Williams1,2, M Natasha Rajah1,2, and Uzay Emir5

1Department of Psychiatry, McGill University, Montreal, QC, Canada, 2Centre d'Imagerie Cérébrale, Douglas Mental Health University Institute, Montreal, QC, Canada, 3Integrated Program in Neuroscience, McGill University, Montreal, QC, Canada, 4Biomedical Engineering, McGill University, Montreal, QC, Canada, 5Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom

Combining optogenetics with fMRI/fMRS (opto-fMRI/opto-fMRS) offers the unique potential to study the whole brain functional or neurochemical effects of stimulating specific neuronal populations within a given brain region.  In this study, we investigated the BOLD functional changes and neurochemical changes resulting from optogenetic stimulation of glutamatergic or GABAergic neurons in the medial septum.  Stimulation of both glutamatergic and GABAergic neurons in the medial septum resulted in prominent bold activation within the hippocampus, and in other regions.  This study represents a unique imaging investigation into the functional response to stimulation of multiple distinct neuronal populations within a single brain region.

1102
Plasma 21
Glycine, a marker of survival in paediatric brain tumours measured with non-invasive Magnetic Resonance Spectroscopy: A five-year survival analysis.
Ben Babourina-Brooks1, Sarah Kohe1, Simrandip K Gill1, Martin Wilson2, Lesley Macpherson3, Nigel P Davies4, and Andrew C Peet1,3

1University of Birmingham, Birmingham, United Kingdom, 2Birmingham University Imaging Centre, University of Birmingham, Birmingham, United Kingdom, 3Birmingham Children's Hospital NHS Foundation Trust, Birmingham, United Kingdom, 4Imaging & Medical Physics, University Hospitals Birmingham NHS Foundation Trust, Birmingham, United Kingdom

Brain tumours have a high mortality rate and are the most common solid tumour of childhood. MRS is a non-invasive imaging technique that measures tumour metabolites which can provide prognostic information to aid clinical management. The metabolite glycine is associated with proliferation and tumorigenesis through the one-carbon metabolic cycle. Glycine concentration has been shown to increase with tumour grade using short echo time MRS at 1.5T, however has not been assessed as a survival marker. This study investigates glycine as a marker of survival in paediatric brain tumours and assesses its added value compared to other established metabolite survival markers.

1103
Plasma 22
About the complementarity of gluCEST and 1H-MRS for the study of neurodegenerative diseases using animal models
Jérémy Pépin1, Clémence Ligneul1, Julien Valette1, Emmanuel Brouillet1, and Julien Flament1,2

1Molecular Imaging Research Center (MIRCen), Commissariat à l’Energie Atomique (CEA), Fontenay-aux-Roses, France, 2UMS27, INSERM, Fontenay-aux-Roses, France

Animal models of neurodegenerative diseases are useful tools to investigate neurodegenerative diseases. However, there is often a wide variety of described models for a same pathology, each model exhibiting its own characteristics. In this work, we used two mouse models of Huntington’s disease exhibiting very different alterations. Using a protocol combining gluCEST imaging and 1H-MRS, we showed that, while gluCEST may evidence alterations in unexpected brain regions, it may also be blind to disease process in certain situations where glutamate levels are preserved. This highlights the complementarity of both methods to identify relevant biomarkers of the pathology.

1104
Plasma 23
A "Glycolytic Index" for quantifying abnormal metabolism in human gliomas using multi-echo amine chemical exchange saturation transfer spin-and-gradient echo echoplanar imaging (ME-aCEST-SAGE-EPI) at 3T
Robert J Harris1, Kevin Leu, Timothy F Cloughesy, Whitney B Pope, Phioanh L Nghiemphu, Albert Lai, Linda M Liau, and Benjamin M Ellingson2

1University of California Los Angeles, Los Angeles, CA, United States, 2Radiological Sciences, University of California Los Angeles, Los Angeles, CA, United States

Abnormal metabolism is a hallmark of cancer. The current study demonstrates use of a novel imaging technique for fast, simultaneous pH- and hypoxia-weighted images using multi-echo amine chemical exchange saturation transfer spin-and-gradient-echo echoplanar imaging (ME-aCEST-SAGE-EPI).  From these data, we demonstrate use of a “glycolytic index”, quantified as the ratio of relative acidity to metabolic rate of oxygen, in estimating metabolically active tumor tissue in 15 patients with gliomas. The glycolytic index showed unique heterogeneous metabolic contrast within the tumor region, and was able to easily stratify tumor from healthy tissue when compared with other imaging techniques. 

1105
Plasma 24
Qualitative and quantitative analysis of amide proton transfer-weighted MR images at 3 Tesla of adult gliomas
Xianlong Wang1, Hao Yu2, Shanshan Jiang2, Yu Wang3, Yanyu Wang2, Ge Zhang4, Chunxiu Jiang2, Guodong Song5, Yi Zhang6, Hye-Young Heo6, Jinyuan Zhou6, and Zhibo Wen2

1Radiology, Zhujiang Hospital of Southern Medical University, Guangzhou, People's Republic of China, 2Radiology, Zhujiang Hospital of Southern Medical University, 3Pathology, Zhujiang Hospital of Southern Medical University, 4Radiology, Hainan General Hospital, 5Radiology, Beijing Hospital, 6Radiology, Johns Hopkins University

We evaluated the reliability and clinical value of amide proton transfer-weighted (APTW) MR imaging at 3 Tesla in adult gliomas. Fifty-seven patients with primary gliomas were recruited and scanned. Two radiologists evaluated the location and size of the APTW hyperintensity and enhancing areas, and measured the tumor and contralateral normal-appearing white matter (CNAWM) APTW values. The correlation between relative APTW (rAPTW) values and pathologic grades was calculated. Results showed APTW analysis had good reliability. APTW images almost showed the same compared with T1-weighted contrast-enhancing (T1W+C) images. The tumor rAPTW values had a strong positive correlation with pathologic grades.

1106
Plasma 25
Cerebral Sodium (23Na) Magnetic Resonance Imaging in Patients with Migraine
Melissa M Ong1, Alexander Schmidt1, Simon Konstandin2, Justus Benrath3, Mathias Meyer1, Lothar R Schad4, Stefan O Schoenberg1, and Stefan Haneder1,5

1Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, University of Heidelberg, Mannheim, Germany, 2University of Bremen, MR-Imaging and Spectroscopy, Faculty 01 (Physics/Electrical Engineering), Bremen, Germany, 3Clinic for Anaesthesiology and Operative Intensive Care, University Medical Center Mannheim, University of Heidelberg, Mannheim, Germany, 4Computer Assisted Clinical Medicine, University Medical Center Mannheim, University of Heidelberg, Mannheim, Germany, 5Institute of Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany

To evaluate sodium concentrations in subgroups of patients with clinically manifest migraine, 12 patients underwent a cerebral 23Na-magnetic resonance imaging examination using a dual-tuned (23Na/1H), dedicated head-coil. 23Na-sequences were reconstructed according to a T1 MP-RAGE, allowing direct cross-referencing of predetermined regions-of-interest (ROI). Significant differences in sodium concentrations could be observed for the white matter and anterior cerebrospinal fluid in patients with and without accompanying aura (p<0.05). These data suggest, that cerebral sodium concentrations may have the potential to differentiate between different subgroups of migraine. 

1107
Plasma 26
Differentiating subtypes of multiple sclerosis lesions using sodium MR imaging
Yulin Ge1, Yongxian Qian, Jean-Christophe Brisset, and Fernando E Boada

1New York University School of Medicine, New York, NY, United States

Although conventional 1H MRI is commonly used for diagnosis and monitoring disease progression in multiple sclerosis (MS), it is not specific to pathology and cell vitality, and is limited in differentiating underlying pathology in MS lesions . In this study, using sodium (23Na) MRI, we demonstrated several subtypes of MS lesions with different sodium concentration changes, which may represent various stages of demyelination and axonal injury. Such information that is not available on conventional imaging may have value in characterize early versus chronic inactive lesions in MS.

1108
Plasma 27
Imaging of the Brachial Plexus using a 3D Dixon-TSE Pulse Sequence with Blood Vessel and CSF Signal Suppression: Preliminary Experience in Children
Barbara Cervantes1, Amber L. Pokorney2, Jan S. Kirschke3, Patricia Cornejo2, Jeffrey H. Miller2, Dimitrios C. Karampinos1, and Houchun Harry Hu2

1Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universitat Munchen, Munich, Germany, 2Department of Radiology, Phoenix Children's Hospital, Phoenix, AZ, United States, 3Department of Neuroradiology, Klinikum rechts der Isar, Technische Universitat Munchen, Munich, Germany

We demonstrate the clinical feasibility and utility of a 3D Dixon TSE sequence in imaging the brachial plexus nerves in children. The employed high spatial resolution MR Neurography (MRN) technique utilizes a refocusing flip angle train to maximize nerve signal and to suppress cerebrospinal fluid signal.  Additionally, a T2-preparation with motion-sensitizing gradients was employed to suppress flowing blood signal and Dixon-based chemical-shift water-fat imaging was used to suppress fat signal in the head, neck, and chest.  We illustrate this MRN technique in delineating the brachial plexus nerves and associated pathological conditions in 25 pediatric patients (age range: 6 months-21 years).

1109
Plasma 28
Diffusion-Tensor-Imaging MR-Neurography for the detection of polyneuropathy in Type 1 diabetes
Michael Vaeggemose1, Mirko Pham2, Steffen Ringgaard3, Hatice Tankisi4, Niels Ejskjaer1, Sabine Heiland5, Per L. Poulsen6, and Henning Andersen1

1Dept. of Neurology, Aarhus University Hospital, Aarhus C, Denmark, 2Dept. of Neuroradiology, Würzburg University Hospital, Würzburg, Germany, 3MR Research Centre, Aarhus University Hospital, Aarhus N, Denmark, 4Dept. of Neurophysiology, Aarhus University Hospital, Aarhus C, Denmark, 5Heidelberg University Hospital, Heidelberg, Germany, 6Dept. of Endocrinology, Aarhus University Hospital, Aarhus C, Denmark

Diabetic peripheral neuropathy (DPN) is an irreversible complication that often remains undiagnosed until advanced stages. Thus, to prevent progression of DPN, early diagnosis is important emphasizing the need for more sensitive diagnostic techniques. Diagnosis is based on a neurological examination, nerve conduction studies, and quantitative sensory testing. Magnetic-resonance-neurography (MRN) enables microstructural nerve fascicle imaging of peripheral neuropathies (1–4). In a previous study on patients with severe DPN we found that diffusion-tensor-imaging (DTI) is a reproducible method in detection of DPN (5). Furthermore, DTI-MRN provided a more accurate group separation than by changes based on T2 or proton-density contrast. 

1110
Plasma 29
Optimal quantitative mapping of Cerabral Metabolic Rate of Oxygen (CMRO2) by combining quantitative susceptibility mapping (QSM)-based method and quantitative BOLD (qBOLD)
Junghun Cho1, Youngwook Kee2, Pascal Spincemaille2, Thanh Nguyen2, Jingwei Zhang1, and Yi Wang1,2

1Cornell University, Ithaca, NY, United States, 2Weill Cornell Medical College, New York, NY, United States

Current two CMRO2 mapping methods, QSM-based method and qBOLD, suffer from the issues in their own model assumptions, such as blood flow challenge and linear relationship assumption between cerebral blood volume (CBV) and flow (CBF) in QSM-based method and the high sensitivity to noise and recent one-compartment assumption in qBOLD. We combined these two models with regularization based on that vein blood volume fraction and vein oxygenation are shared, which removes the challenge and linear assumption in QSM method and alleviates the high noise sensitivity and one-compartment assumption issue in qBOLD. The proposed model provided more uniform OEF and CMRO2. 

1111
Plasma 30
Asynchronous Local Analysis of simultaneous BOLD ASL Multislice Acquisition (ALABAMA): Toward Whole-Brain Noninvasive Estimation of Resting-State Neuronal-Vascular Coupling
Vincent Schmithorst1, Vince Lee1, and Ashok Panigrahy1

1Radiology, Children's Hospital of Pittsburgh of UPMC, Pittsburgh, PA, United States

A method (ALABAMA) for regional estimation of the coupling between R2* fluctuations and log signal intensity (S0) (related to R2*-CBF coupling via a calibration factor) during the resting state is proposed.  The method incorporates pseudo-continuous ASL (pCASL) labeling together with simultaneous multi-slice (SMS) and double-echo EPI acquisition for fast temporal resolution.  The sequence yields robust positive ΔR2*-Δln S0 correlations in most resting-state networks, which may then be used to estimate resting-state neuronal-vascular coupling (NVC) with an additional calibration scan.  However, negative correlations were found in posterior DMN and central executive network (CEN) regions, possibly reflective of altered flow-metabolism relationships.