Motion-Dependent Low-Order Predictive Linear Model for Patient Safety Assessment at 7T with Technically Feasible Coil Models

MultichannelMRI receivecoil based on artificial material

Author:Eugene Koreshin  Denis Burov  Pavel Seregin  

Session Type:Online Gather.town Pitches  

Session Date:Monday, 09 May 2022  

Topic:Module 24: RF Coils, Technologies & Sequences  

Session Name:RF Coils, Technologies & Sequences I  

Program Number:3235  

Room Session:5  

Institution:ITMO University  

A multinuclear 4-channel 2H loop and 4-channel 1H microstrip array coil for human head MRS/MRI at 7T

Negligible loss in double tuning when stacking 1H to 31P dipoles in an 8-channel dipole array with 24 receivers at 7T

Nested Geometrically Decoupled Triple-Tuned Volume Coil for 1H, 23Na and 31P at 4.7T

Author:Joseph Busher  Edith Valle  Steven Wright  Mary McDougall  

Session Type:Digital Poster  

Session Date:Tuesday, 10 May 2022  

Topic:Module 24: RF Coils, Technologies & Sequences  

Session Name:High-Field RF Coils & Arrays II  

Program Number:1539  

Room Session:Exhibition Hall:S8 & S9  

Institution:Texas A&M  

Noise Considerations for a Microsolenoid at 15.2T Designed for MR Microscopy

On-coil digitization with a 130nm CMOS receiver: Electromagnetic compatibility and use for a wearable knee array

Optimal control pulse design as a low power alternative to BIR4 excitation pulses

Optimization and Analysis of Shielded Loop Resonators towards Modular Coil Arrays

Optimization of the Double-Row 16-channel Transmit-only RF Array Coil for Human Brain Imaging at 9.4T.

Parallel transmission RF pulse design for simultaneous multi-slab excitation at 7 Tesla: a simulation study

Performance of Short, Gradient Modulated RF Pulses due to Asynchrony Between RF and Gradient Waveforms

Prostate imaging with Integrated Multi-modal Antenna with coupled Radiating dipoles (I-MARS) at 7T

Pulsed Selective Excitation in Multiphoton MRI

Pycoilib: a free and pedagogical tool for the calculation of self/mutual inductance of coils of arbitrary geometry in python

Rapid B1+ Mapping using a Sandwiched Train Saturated TurboFLASH Sequence at 7T

RF Coils for Evaluation of Duchenne Muscular Dystrophy Biomarkers at 4.7 T

Self-shielded and self-decoupled transmit RF array for 7T head imaging

Shielded-coaxial-cable (SCC) coils - the array configuration for maximized central SNR at 7T MRI

Simulation validation of an 8-channel parallel-transmit dipole array: including RF losses for robust correlation with experimental results

Author:Jérémie Clément  Özlem Ipek  

Session Type:Digital Poster  

Session Date:Tuesday, 10 May 2022  

Topic:Module 24: RF Coils, Technologies & Sequences  

Session Name:High-Field RF Coils & Arrays II  

Program Number:1540  

Room Session:Exhibition Hall:S8 & S9  

Institution:King's College London  

Simultaneous Multislice Imaging Using Multiphoton MRI

Simultaneous Multislice pTx for Readout-Segmented Diffusion Imaging at 7 T

Simultaneous Multi Slice using Hadamard like encoding with non-Hadamard factors

Smart MetaBox: Metamaterial arrangement for volume-homogeneous SNR enhancement

SNR and Field Strength with Small Surface Coils

SNR Evaluation with High Input Impedance Preamplifier Decoupling Performance for a 2-Layer and 32-Channel Receive Array for Brain Imaging at 7T

Studying the influence of cryogenic cooling and B0 alignment on Si PIN diode operation in active decoupling circuits

Target specific optimization of the transmit k-space trajectory stack-of-spirals and SPINS for pTx pulse design

­The Double Bent Dipole (DBD): A hybrid element designed for combined RF/B0 shimming for imaging at 10.5T

Transmit Performance of a Metamaterial Slab as a Passive RF Shimming Element for 3T MRI

Twenty-channel, Highly-stretchable, Overlapped, Receive (THOR) Array

Velocity selective arterial spin labelling using parallel transmission