Browse All

Current Filters

CLEAR FILTER x

TITLE

Using the end of the feeding cable directly as a flexible antenna at 7T: the coax monopole antenna

Using the end of the feeding cable directly as a flexible antenna at 7T: the coax monopole antenna

MR thermometry of RF heating in the human brain at 7T using the harmonical initialized multi-echo model with SVD-based motion correction

MR thermometry of RF heating in the human brain at 7T using the harmonical initialized multi-echo model with SVD-based motion correction

Can fMRI metrics lateralize epileptogenic hypometabolic FDG-PET regions? A simultaneous PET/MR investigation in focal epilepsy

Assessing microstructural and microvascular abnormalities in hospitalized COVID-19 patients using intravoxel incoherent motion imaging

Higher blood flow velocity pulsatility relates to increased interstitial fluid diffusivity - a potential proxy of high perivascular fluid flow

Structural waste clearance markers in the elderly: sex differences in the relation between perivascular and parasagittal dural space volume

The effect of MultiBand acquisition on cerebral inversion recovery intravoxel incoherent motion imaging

Increased pulsatility is associated with higher blood flow in the cerebral microvasculature as assessed with 7T MRI

7T spin-echo dynamic susceptibility contrast MRI to assess cerebral microvascular perfusion

Respiratory Motion Artifact Simulation for DL application in Cardiac MR Image Quality Assessment

Data Augmentation with Simulated Images for Generalizable Brain MRI Super-Resolution

Cardiac MR Image Segmentation in the Presence of Respiratory Motion Artifacts<

Author:Yasmina Al Khalil  Sina Amirrajab  Josien Pluim  Marcel Breeuwer  Cian Scannell  

Session Type:Digital Poster  

Session Date:Wednesday, 07 June 2023  

Session Name:Segmentation II  

Program Number:3761  

Room Session:Exhibition Halls D/E  

Institution :Eindhoven University of Technology  Philips Healthcare  

31P MRSI coil combination using 23Na sensitivity information acquired with the same loop array at 7T: preliminary verification

Predicting Uncertainty of Metabolite Quantification in Magnetic Resonance Spectroscopy with Applications for Adaptive Ensembling

Evaluation of different multi-echo combinations on objective depression prognosis in an emotional face-matching task

Sparse regression-based delineation of air-motion artifacts for real-time correction of PRFS thermometry

Author:Sven Nouwens  Maarten Paulides  Maurice Heemels  

Session Type:Digital Poster  

Session Date:Thursday, 08 June 2023  

Session Name:Thermometry  

Program Number:4991  

Room Session:Exhibition Halls D/E  

Institution :Eindhoven University of Technology  Erasmus MC  

Deep Learning based drift field correction for MR Thermometry in the upper leg at 7T

Conditional VAE for Single-Voxel MRS Data Generation

Integrating intravoxel incoherent motion and diffusion tensor MRI of the brain into a single fast acquisition - a model-selection study

Multi-Channel Coil Design & Applications: Neuro

Author:Irena Zivkovic  

Session Type:Weekend Course  

Session Date:Sunday, 04 June 2023  

Session Name:Multi-Channel Transmit: From Coil to Pulse Design  

Program Number:

Room Session:717A/B  

Institution :Eindhoven University of Technology