Browse All

Current Filters

CLEAR FILTER x

TITLE

A 64-Channel Phased-Array Head Neck Coil for Neurovascular/fMRI at 3T

Author:Haoqin Zhu  Xiaoyu Yang  Michael Wyban  Yiping Guan  Yoshinori Hamamura  Yuji Takano  Kazuya Okamoto  

Institution:Canon Medical Research USA, Inc.  Canon Medical Systems Corporation  Quality Electrodynamics, LLC (QED)  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:09:15  

Session Name:RF: Other  

Program Number:1525  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 92  

Abdominal Diffusion-Weighted Imaging with Stretched-Exponential Model: Phantom and Clinical Studies

Amid Proton Transfer-Weighted Imaging vs. Diffusion-Weighted Imaging vs. FDG-PET/CT: Capability for Management of Solitary Pulmonary Nodules

Author:Yoshiharu Ohno  Masao Yui  Takeshi Yoshikawa  Shinichiro Seki  Katsusuke Kyotani  Takamichi Murakami  

Institution:Canon Medical Systems Corporation  Kobe University Graduate School of Medicine  Kobe University Hospital  

Session Type:Oral  

Session Date:Monday, 13 May 2019  

Session Time:13:45  

Session Name:Cutting-Edge Advances in Cancer Imaging  

Program Number:0195  

Presentation Time:14:21   

Room Number:Room 520A-F  

Computer Number:

Application of Deep Learning Reconstruction for Denoising of Compressed Sensing non-contrast coronary MRA images to achieve improved Diagnostic Confidence.

Comparison of Capabilities for Pulmonary Functional Loss Evaluation and Clinical Stage Classification between 3D Oxygen-Enhanced MRI at 3T System and Thin-Section CT in Smokers

Author:Yoshiharu Ohno  Masao Yui  Takeshi Yoshikawa  Shinichiro Seki  Katsusuke Kyotani  Takamichi Murakami  

Institution:Canon Medical Systems Corporation  Kobe University Graduate School of Medicine  Kobe University Hospital  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:14:45  

Session Name:Second Wind: Xenonphobic  

Program Number:1892  

Presentation Time:14:45   

Room Number:Exhibition Hall  

Computer Number:Computer 116  

Comparison of the Capability for Distinguishing Malignant from Benign Pulmonary Nodules among DWI with FASE Sequence at a 3T System, DWIs with EPI Sequence at 1.5T and 3T Systems and FDG-PET/CT

Author:Yoshiharu Ohno  Masao Yui  Yoshimori Kassai  Takeshi Yoshikawa  Shinichiro Seki  Katsusuke Kyotani  Takamichi Murakami  

Institution:Canon Medical Systems Corporation  Kobe University Graduate School of Medicine  Kobe University Hospital  

Session Type:Digital Poster  

Session Date:Wednesday, 15 May 2019  

Session Time:15:45  

Session Name:Lung: Proton-Based Imaging  

Program Number:4097  

Presentation Time:15:45   

Room Number:Exhibition Hall  

Computer Number:Computer 70  

Comparison of the Capability for Quantitative Distinguishing Malignant from Benign Solitary Pulmonary Nodules among actual DWI, computed DWIs with different b values and FDG-PET/CT

Comparison of Therapeutic Effect Prediction among Dynamic Perfusion Area-Detector CT, Dynamic Perfusion MR Imaging and FDG-PET/CT in Small Cell Lung Cancer Patients with Limited Disease

Author:Yoshiharu Ohno  Masao Yui  Shigeharu Ohyu  Yasuko Fujisawa  Shinichiro Seki  Takeshi Yoshikawa  Katsusuke Kyotani  Takamichi Murakami  

Institution:Canon Medical Systems Corporation  Kobe University Graduate School of Medicine  Kobe University Hospital  

Session Type:Digital Poster  

Session Date:Wednesday, 15 May 2019  

Session Time:15:45  

Session Name:Lung: Proton-Based Imaging  

Program Number:4096  

Presentation Time:15:45   

Room Number:Exhibition Hall  

Computer Number:Computer 69  

Continuously visualizing slow flow using SSFP

Author:Koichi Oshio  Masao Yui  Seiko Shimizu  Shinya Yamada  

Institution:Canon Medical Systems Corporation  Keio University School of Medicine  Toshiba Rinkan Hospital  

Session Type:Digital Poster  

Session Date:Tuesday, 14 May 2019  

Session Time:14:30  

Session Name:Novel Neuroimaging Methods  

Program Number:2974  

Presentation Time:14:30   

Room Number:Exhibition Hall  

Computer Number:Computer 156  

Convolutional Neural Networks with Aliasing Layers for Correcting Parallel Imaging and EPI Ghost Artifacts

Author:Hidenori Takeshima  

Institution:Canon Medical Systems Corporation  

Session Type:Digital Poster  

Session Date:Thursday, 16 May 2019  

Session Time:09:15  

Session Name:Machine Learning for Image Reconstruction: Breakthroughs  

Program Number:4695  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 152  

Deep Learning Based Adaptive Noise Reduction in Multi-Contrast MR Images

Author:Kensuke Shinoda  Kenzo Isogawa  Masahito Nambu  Yuichi Yamashita  Mika Kitajima  Hiroyuki Uetani  Yasuyuki Yamashita  

Institution:Canon Medical Systems Corporation  Kumamoto University  Toshiba Corporation  

Session Type:Digital Poster  

Session Date:Thursday, 16 May 2019  

Session Time:09:15  

Session Name:Machine Learning for Image Reconstruction: Breakthroughs  

Program Number:4701  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 158  

Evaluation of Variable-TE computed Diffusion Weighted Imaging Technique using Deep Learning based Noise Reduction

Author:Hiroshi Kusahara  Yuki Takai  Kensuke Shinoda  Yoshimori Kassai  

Institution:Canon Medical Systems Corporation  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:13:45  

Session Name:AI & Radiomics in Body MRI  

Program Number:1717  

Presentation Time:13:45   

Room Number:Exhibition Hall  

Computer Number:Computer 112  

Fast Acquisition and Low-delay Reconstruction of Stack-of-stars Trajectory Using Temporal Multiresolution Images and a Convolutional Neural Network

Author:Hidenori Takeshima  Hideaki Kutsuna  

Institution:Canon Medical Systems Corporation  

Session Type:Power Pitch  

Session Date:Tuesday, 14 May 2019  

Session Time:13:30  

Session Name:Pitch: Machine Learning Unleashed 1  

Program Number:0467  

Presentation Time:13:30   

Room Number:Power Pitch Theater B - Exhibition Hall  

Computer Number:

Fast Acquisition and Low-delay Reconstruction of Stack-of-stars Trajectory Using Temporal Multiresolution Images and a Convolutional Neural Network

Author:Hidenori Takeshima  Hideaki Kutsuna  

Institution:Canon Medical Systems Corporation  

Session Type:Power Pitch Poster  

Session Date:Tuesday, 14 May 2019  

Session Time:14:30  

Session Name:Poster: Machine Learning Unleashed 1  

Program Number:0467  

Presentation Time:14:30   

Room Number:Power Pitch Theater B - Exhibition Hall  

Computer Number:Plasma 18  

High-b Abdominal FASE-DWI: Phantom and Clinical Studies

Author:Takeshi Yoshikawa  Yoshiharu Ohno  Masao Yui  Yoshimori Kassai  Ryuji Shimada  Katsusuke Kyotani  Shinichiro Seki  

Institution:Canon Medical Systems Corporation  Kobe University Graduate School of Medicine  Kobe University Hospital  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:14:45  

Session Name:What Are We, Chopped Liver?  

Program Number:1800  

Presentation Time:14:45   

Room Number:Exhibition Hall  

Computer Number:Computer 23  

Impacts of different b and TE values on quality of 3T diffusion-weighted imaging of the liver using a high gradient magnetic field: feasibility of ultrahigh b value of 3000

Improved vessel delineation in whole-heart coronary MRA with sub-millimeter isotropic resolution using deep learning reconstruction compared with routine whole-heart coronary MRA

Investigation of antenna effect on non-contact monitoring of heart and respiration rate

Author:Takafumi Ohishi  

Institution:Canon Medical Systems Corporation  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:09:15  

Session Name:MRI Unplugged: Wireless, Portable & Flexible  

Program Number:1555  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 122  

T1, T2 relaxometry for tissue cell density quantification in glioma imaging: Exploration study via 11C-methionine PET and its validation via stereotactic tissue sampling

Visualizing the Myocardium in-vivo with a 3D uTE Acquisition

Author:Larry Kasuboski  Jason Ortman  Sho Tanaka  Bharath Ambale Venkatesh  Joao Lima  

Institution:Canon Medical Research USA  Canon Medical Systems Corporation  Johns Hopkins University School of Medicine  

Session Type:Digital Poster  

Session Date:Thursday, 16 May 2019  

Session Time:09:15  

Session Name:Improving Definition & Reducing Artifacts  

Program Number:4671  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 128  

Whole-Body MRI and PET/MRI at 1.5T and 3T MR System: Comparison of TNM Stage Assessment Capability with PET/CT in Non-Small Cell Carcinoma (NSCLC)

Author:Yoshiharu Ohno  Takeshi Yoshikawa  Masao Yui  Kota Aoyagi  Yoshimori Kassai  Shinichiro Seki  Katsusuke Kyotani  Takamichi Murakami  

Institution:Canon Medical Systems Corporation  Kobe University Graduate School of Medicine  Kobe University Hospital  

Session Type:Digital Poster  

Session Date:Wednesday, 15 May 2019  

Session Time:15:45  

Session Name:Lung: Proton-Based Imaging  

Program Number:4098  

Presentation Time:15:45   

Room Number:Exhibition Hall  

Computer Number:Computer 71