A light-weight, flexible head and neck coil design for a patient-friendly MR-only Radiation Therapy workflow

Author:Cristina Cozzini  Chad Bobb  Mathias Engström  Sandeep Kaushik  Robert Molthen  Dan Rettmann  Venkat Goruganti  Wen-Yang Chiang  Florian Wiesinger  

Institution:GE Global Research  Ge Healthcare  GE Healthcare  NeoCoil  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:09:15  

Session Name:MRI Unplugged: Wireless, Portable & Flexible  

Program Number:1548  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 115  

A Novel and Efficient No-tuning Inductive-coupling Q-damping Circuit for a Low-field Portable MRI System

Author:Zhi Hua Ren  Guang Yang  Pengde Wu  Sergei Obruchkov  Robin Dykstra  Shao Ying Huang  

Institution:Sichuan University  Singapore University of Technology and Design  Victoria University of Wellington  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:09:15  

Session Name:MRI Unplugged: Wireless, Portable & Flexible  

Program Number:1544  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 111  

A Novel Ultra-Flexible High-Resolution 50-Channel RF Coil for Prostate, Rectal and Pelvis Imaging

Author:Yun-Jeong Stickle  Clyve Konrad Follante  Mark Giancola  Fraser Robb  Victor Taracila  Balint Franko  Holly Blahnik  Robert Stormont  

Institution:Ge Healthcare  GE Healthcare  Ge Healthcare  GE Healthcare  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:09:15  

Session Name:MRI Unplugged: Wireless, Portable & Flexible  

Program Number:1547  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 114  

A Transceive Inductively Coupled Coil using Dual Wireless Coils for Small Animal Imaging at 15.2T

About the MRI compatibility of fuel cells as the power source for PET detectors

Author:Nicolas Gross-Weege  Thomas Dey  Bjoern Weissler  Teresa Nolte  Johannes Ramler  Martin Müller  Detlef Stolten  Volkmar Schulz  

Institution:Forschungszentrum Julich GmbH  Philips Research Europe  RWTH Aachen University  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:09:15  

Session Name:MRI Unplugged: Wireless, Portable & Flexible  

Program Number:1539  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 106  

An Aubert Ring Aggregate Magnet Helmet for 3D Head Imaging in a Low-field Portable MRI

Author:Zhi Hua Ren  Shao Ying Huang  

Institution:Singapore University of Technology and Design  National University of Singapore  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:09:15  

Session Name:MRI Unplugged: Wireless, Portable & Flexible  

Program Number:1545  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 112  

Characterization of In-Bore 802.11ac Wi-Fi Performance

Author:Christopher Vassos  Fraser Robb  Shreyas Vasanawala  John Pauly  Greig Scott  

Institution:Ge Healthcare  GE Healthcare  Stanford University  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:09:15  

Session Name:MRI Unplugged: Wireless, Portable & Flexible  

Program Number:1543  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 110  

Clock Transmission Methods for Wireless MRI: A Study on Clock Jitter & Impact on Data Sampling

Author:Jonathan Lu  Thomas Grafendorfer  Fraser Robb  Simone Winkler  Shreyas Vasanawala  John Pauly  Greig Scott  

Institution:GE Healthcare Inc  Stanford University  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:09:15  

Session Name:MRI Unplugged: Wireless, Portable & Flexible  

Program Number:1542  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 109  

Design of a novel class of open MRI devices with nonuniform Bo, field cycling, and RF spatial encoding

Author:R. Todd Constable  Charles Rogers III  Baosong Wu  Kartiga Selvaganesan  Gigi Galiana  

Institution:Yale school of medicine  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:09:15  

Session Name:MRI Unplugged: Wireless, Portable & Flexible  

Program Number:1546  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 113  

Design of a reconfigurable endoluminal coil using MEMS switches

Harvesting Power Wirelessly from MRI Scanners

Author:Kelly Byron  Fraser Robb  Shreyas Vasanawala  John Pauly  Greig Scott  

Institution:Ge Healthcare  GE Healthcare  Stanford University  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:09:15  

Session Name:MRI Unplugged: Wireless, Portable & Flexible  

Program Number:1535  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 102  

Imaging of Stroke in Rats using a Clinical Scanner and an Inductively Coupled Specially Designed Receiver Coil

Investigation of antenna effect on non-contact monitoring of heart and respiration rate

Author:Takafumi Ohishi  

Institution:Canon Medical Systems Corporation  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:09:15  

Session Name:MRI Unplugged: Wireless, Portable & Flexible  

Program Number:1555  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 122  

Metasurface-based wireless coil to control RF magnetic field distribution inside 1.5T MR scanner.

Author:Egor Kretov  Alena Shchelokova  Alexey Slobozhanyuk  

Institution:ITMO University  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:09:15  

Session Name:MRI Unplugged: Wireless, Portable & Flexible  

Program Number:1557  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 124  

Restraint system with integrated receive array for minimizing head motion during awake marmoset imaging

Author:Kyle Gilbert  David Schaeffer  Stefan Everling  Ravi Menon  

Institution:The University of Western Ontario  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:09:15  

Session Name:MRI Unplugged: Wireless, Portable & Flexible  

Program Number:1538  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 105  

Sensitivity and Uniformity Improvement of Phased Array MR Images Using Inductive Coupling and RF Detuning Circuits

Author:Bu Park  Sunder Rajan  Brent McCright  

Institution:FDA  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:09:15  

Session Name:MRI Unplugged: Wireless, Portable & Flexible  

Program Number:1556  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 123  

Simulations of Integrated Radio-Frequency/Wireless Coil Designs for Simultaneous MR Image Acquisition and Wireless Communication

Author:Julia Bresticker  Zachary Thompson  Devin Willey  Allen Song  Dean Darnell  Trong-Kha Truong  

Institution:Duke University  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:09:15  

Session Name:MRI Unplugged: Wireless, Portable & Flexible  

Program Number:1541  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 108  

Title: Enhancement of SNR and Sensitivity of Image in MR using Left Handed Metamaterial Lens Focusing/Converging in both direction.

Author:Tejkiran Patil  Bhaskara Naik  Rajesh Harsh  

Institution:Society for Applied Microwave Electronics Engineering and Research  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:09:15  

Session Name:MRI Unplugged: Wireless, Portable & Flexible  

Program Number:1554  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 121  

Ultra-Flexible Electro-Textile 4-Channel MRI RF Coil Array for Neck MRI

Author:Daisong Zhang  Le Zhang  Ashley Prosper  Holden Wu  Yahya Rahmat-Samii  

Institution:University of California, Los Angeles  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:09:15  

Session Name:MRI Unplugged: Wireless, Portable & Flexible  

Program Number:1540  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 107  

Universal WiGig MRI receiver platform with auto-synchronised clock module and ZYNQ-based high-speed digitizer

Wireless Digital Data Transfer based on WiGig/IEEE 802.11ad with Self-Shielded Antenna Gain Enhancement for MRI

Wireless Power Transfer Compatibility and Noise Issues in MRI

Author:Kelly Byron  Fraser Robb  Shreyas Vasanawala  John Pauly  Greig Scott  

Institution:Ge Healthcare  GE Healthcare  Stanford University  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:09:15  

Session Name:MRI Unplugged: Wireless, Portable & Flexible  

Program Number:1534  

Presentation Time:09:15   

Room Number:Exhibition Hall  

Computer Number:Computer 101