A Biophysical Model of Iron-Induced Relaxation in Human Substantia Nigra for Early Stage Parkinson Diagnostic

A totally balanced spin lock preparation module for accurate and artifact-free T1?-mapping

Author:Maximilian Gram  Daniel Gensler  Anton Xu  Peter Nordbeck  Wolfgang Rudolf Bauer  Peter Michael Jakob  Michael Seethaler  

Institution:University Hospital Würzburg  University of Würzburg  

Session Type:Oral  

Session Date:Thursday, 16 May 2019  

Session Time:16:00  

Session Name:Relaxometry: Measuring, Understanding & Using  

Program Number:1215  

Presentation Time:17:12   

Room Number:Room 511BCEF  

Computer Number:

Click Your Fat Away: Rapid Synthetic Knee MR Imaging with Switchable Fat and Magnetization-Transfer Contrast

Free Breathing R2* Mapping Using Three-Dimensional Self-Gating Motion-Compensated Stack-of-Radial MRI

Author:Xiaodong Zhong  Tess Armstrong  Marcel Nickel  Stephan Kannengiesser  Li Pan  Vibhas Deshpande  Holden Wu  

Institution:Siemens Healthcare GmbH  Siemens Healthcare GmbH  Siemens Healthineers  University of California Los Angeles  

Session Type:Oral  

Session Date:Thursday, 16 May 2019  

Session Time:16:00  

Session Name:Relaxometry: Measuring, Understanding & Using  

Program Number:1216  

Presentation Time:17:24   

Room Number:Room 511BCEF  

Computer Number:

Free-Breathing Water, Fat, and Iron Quantification in the Abdomen Using Radial Multi-Echo Acquisition and Respiratory-Resolved Model-Based Reconstruction

Longitudinal assessment of relaxation and magnetization transfer saturation rates during formalin fixation across fiber pathways of the human brain

Author:Tobias Streubel  Mohammad Ashtarayeh  Herbert Mushumba  Sebastian Papazoglou  Klaus Püschel  Siawoosh Mohammadi  

Institution:University Medical Center Hamburg-Eppendorf  Max Planck Institute for Human Cognitive and Brain Sciences  

Session Type:Oral  

Session Date:Thursday, 16 May 2019  

Session Time:16:00  

Session Name:Relaxometry: Measuring, Understanding & Using  

Program Number:1212  

Presentation Time:16:36   

Room Number:Room 511BCEF  

Computer Number:

Multi-Vendor Validation of Controlled Saturation Magnetization Transfer (CSMT) for VFA T1 and T2 mapping

Author:Rui Pedro A G Teixeira  Radhouene Neji  Tobias Wood  Ana Baburamani  Shaihan Malik  Jo Hajnal  

Institution:King's College London  King's College London  Siemens Healthcare Limited  

Session Type:Oral  

Session Date:Thursday, 16 May 2019  

Session Time:16:00  

Session Name:Relaxometry: Measuring, Understanding & Using  

Program Number:1209  

Presentation Time:16:00   

Room Number:Room 511BCEF  

Computer Number:

Repeatability Measurements of Magnetic Resonance Fingerprinting Metrics using ACR and ISMRM/NIST Phantoms: A Multi-Center Study