Achieving sub-mm clinical diffusion MRI resolution by removing noise during reconstruction using random matrix theory

Author:Gregory Lemberskiy  Steven Baete  Jelle Veraart  Timothy Shepherd  Els Fieremans  Dmitry Novikov  

Institution:NYU School of Medicine  

Session Type:Oral  

Session Date:Wednesday, 15 May 2019  

Session Time:08:15  

Session Name:Diffusion MRI: Acquisition & Reconstruction  

Program Number:0770  

Presentation Time:09:03   

Room Number:Room 710B  

Computer Number:

An efficient reconstruction by combining tilted-CAIPI with eddy-current calibration for high-resolution distortion-free diffusion imaging using DIADEM

Diffusion MRI with b=1000 s/mm2 at TE < 22 ms using single-shot spiral readout and ultra-strong gradients: Implications for microstructure imaging

Author:Lars Mueller  Suryanarayana Umesh Rudrapatna  Chantal Tax  Richard Wise  Derek Jones  

Institution:Cardiff University  

Session Type:Oral  

Session Date:Wednesday, 15 May 2019  

Session Time:08:15  

Session Name:Diffusion MRI: Acquisition & Reconstruction  

Program Number:0766  

Presentation Time:08:15   

Room Number:Room 710B  

Computer Number:

Double Echo Steady State (DESS) Cones for Motion-Robust Steady-State Diffusion-Weighted Imaging

Author:Catherine Moran  Joseph Cheng  Christopher Sandino  Marcus Alley  Bruce Daniel  Michael Carl  Brian Hargreaves  

Institution:Ge Healthcare  GE Healthcare  Stanford University  

Session Type:Oral  

Session Date:Wednesday, 15 May 2019  

Session Time:08:15  

Session Name:Diffusion MRI: Acquisition & Reconstruction  

Program Number:0769  

Presentation Time:08:51   

Room Number:Room 710B  

Computer Number:

High-fidelity, high-isotropic resolution diffusion imaging through gSlider acquisition with B1+ & T1 corrections and multi-coil B0 shim array

Author:Congyu Liao  Jason Stockmann  Qiyuan Tian  Berkin Bilgic  Mary Manhard  Lawrence Wald  Kawin Setsompop  

Institution:Massachusetts General Hospital  Harvard Medical School  Harvard Medical School  

Session Type:Oral  

Session Date:Wednesday, 15 May 2019  

Session Time:08:15  

Session Name:Diffusion MRI: Acquisition & Reconstruction  

Program Number:0768  

Presentation Time:08:39   

Room Number:Room 710B  

Computer Number:

High-Resolution Diffusion MRI: In-Vivo Demonstration of the SNR Benefit of Single-Shot Spiral Acquisition vs. EPI

Author:Yoojin Lee  Bertram Wilm  Zoltan Nagy  Klaas Prüssmann  

Institution:ETH Zürich  University of Zürich  

Session Type:Oral  

Session Date:Wednesday, 15 May 2019  

Session Time:08:15  

Session Name:Diffusion MRI: Acquisition & Reconstruction  

Program Number:0767  

Presentation Time:08:27   

Room Number:Room 710B  

Computer Number:

High-Resolution Isotropic Diffusion MRI Using Simultaneous Multi-slab (SMSlab) Acquisition

Author:Erpeng Dai  Yuhsuan Wu  Hua Guo  

Institution:Tsinghua University  Tsinghua University  Stanford University  

Session Type:Oral  

Session Date:Wednesday, 15 May 2019  

Session Time:08:15  

Session Name:Diffusion MRI: Acquisition & Reconstruction  

Program Number:0774  

Presentation Time:09:51   

Room Number:Room 710B  

Computer Number:

Toward high-SNR, motion-robust diffusion MRI of the liver using optimized gradient waveforms, non-gated free-breathing acquisitions, and motion-corrected averaging

Author:Ruiqi Geng  Yuxin Zhang  Huiwen Luo  Diego Hernando  

Institution:University of Wisconsin, Madison  Vanderbilt University  

Session Type:Oral  

Session Date:Wednesday, 15 May 2019  

Session Time:08:15  

Session Name:Diffusion MRI: Acquisition & Reconstruction  

Program Number:0772  

Presentation Time:09:27   

Room Number:Room 710B  

Computer Number: