Browse All

Current Filters

CLEAR FILTER x

TITLE

Institution:

Correlating the measured fast/slow decay components of tissue sodium to the intra-/extra-cellular sodium concentrations

Author:Jinhu Xiong  William Kearney  Mathews Jacobs  Rolf Schulte  Baolian Yang  Vincent Magnotta  

Institution:Ge Healthcare  GE Healthcare  University of Iowa  

Session Type:Digital Poster  

Session Date:Thursday, 16 May 2019  

Session Time:08:15  

Session Name:Robust & Reproducible Quantitation  

Program Number:4466  

Presentation Time:08:15   

Room Number:Exhibition Hall  

Computer Number:Computer 93  

Dynamic MRI using Model-based deep learning and SToRM priors: MoDL-SToRM

Author:Sampurna Biswas  Hemant Aggarwal  Mathews Jacob  

Institution:University of Iowa  

Session Type:Oral  

Session Date:Tuesday, 14 May 2019  

Session Time:15:45  

Session Name:Machine Learning for Image Reconstruction  

Program Number:0661  

Presentation Time:16:33   

Room Number:Room 710B  

Computer Number:

Fast dynamic speech MRI at 3 Tesla using variable density spirals and constrained reconstruction

Author:Sajan Goud Lingala  Douglas Blake  Stanley Kruger  David Meyer  Eileen Finnegan  Ingo Titze  Eric Hoffman  

Institution:Shenandoah University  University of Iowa  

Session Type:Digital Poster  

Session Date:Thursday, 16 May 2019  

Session Time:13:45  

Session Name:Image Reconstruction I  

Program Number:4744  

Presentation Time:13:45   

Room Number:Exhibition Hall  

Computer Number:Computer 26  

Free breathing & Ungated Multi-Slice cardiac cine MRI using spiral-SToRM

Author:Abdul Haseeb Ahmed  Sunrita Poddar  Stanley Kruger  Prashant Nagpal  Rolf Schulte  Mathews Jacob  

Institution:Healthcare, GE  University of Iowa  University of Iowa Hospitals and Clinics  

Session Type:Digital Poster  

Session Date:Thursday, 16 May 2019  

Session Time:08:15  

Session Name:Motion Correction: Non-Brain  

Program Number:4479  

Presentation Time:08:15   

Room Number:Exhibition Hall  

Computer Number:Computer 107  

Improved MUSSELS Reconstruction for High Resolution Diffusion Weighted Imaging Using Fast Iterative Re-weighted Least Squares Algorithm

Author:Merry Mani  Hemant Aggarwal  Vincent Magnotta  Mathews Jacob  

Institution:University of Iowa  

Session Type:Digital Poster  

Session Date:Wednesday, 15 May 2019  

Session Time:08:15  

Session Name:Diffusion MRI: Image Reconstruction  

Program Number:3339  

Presentation Time:08:15   

Room Number:Exhibition Hall  

Computer Number:Computer 1  

Improved spiral dynamic MRI of vocal tract shaping at 3 Tesla using dynamic off resonance artifact correction

Author:Sajan Goud Lingala  Yongwan Lim  Stanley Kruger  Krishna Nayak  

Institution:University of Iowa  University of Southern California  

Session Type:Oral  

Session Date:Tuesday, 14 May 2019  

Session Time:08:15  

Session Name:MRI: Overcoming Our Imperfections  

Program Number:0441  

Presentation Time:08:27   

Room Number:Room 710B  

Computer Number:

Inversion Recovery Cardiac and Respiratory Self-gated Simultaneous Acquisition of Cine and LGE Images Using a Golden-angle Spiral Pulse Sequence

Author:Ruixi Zhou  Yang Yang  Daniel Weller  Abdul Ahmed  John Mugler  Mathews Jacob  Michael Salerno  

Institution:University of Iowa  University of Virginia  

Session Type:Digital Poster  

Session Date:Monday, 13 May 2019  

Session Time:16:00  

Session Name:Myocardial Function & Deformation 1  

Program Number:2118  

Presentation Time:16:00   

Room Number:Exhibition Hall  

Computer Number:Computer 168  

Multi-Shot Diffusion MRI using Deep MUSSELS

Author:Hemant K. Aggarwal  Merry P. Mani  Mathews Jacob  

Institution:University of Iowa  

Session Type:Power Pitch  

Session Date:Tuesday, 14 May 2019  

Session Time:13:30  

Session Name:Pitch: Machine Learning Unleashed 1  

Program Number:0476  

Presentation Time:13:30   

Room Number:Power Pitch Theater B - Exhibition Hall  

Computer Number:

Multi-Shot Diffusion MRI using Deep MUSSELS

Author:Hemant K. Aggarwal  Merry P. Mani  Mathews Jacob  

Institution:University of Iowa  

Session Type:Power Pitch Poster  

Session Date:Tuesday, 14 May 2019  

Session Time:14:30  

Session Name:Poster: Machine Learning Unleashed 1  

Program Number:0476  

Presentation Time:14:30   

Room Number:Power Pitch Theater B - Exhibition Hall  

Computer Number:Plasma 27  

Navigator-less Spiral SToRM for Free breathing and Ungated Cardiac CINE MRI

Author:Abdul Haseeb Ahmed  Ruixi Zhou  Yang Yang  Michael Salerno  Mathews Jacob  

Institution:University of Iowa  University of Virginia  

Session Type:Digital Poster  

Session Date:Thursday, 16 May 2019  

Session Time:08:15  

Session Name:Motion Correction: Non-Brain  

Program Number:4480  

Presentation Time:08:15   

Room Number:Exhibition Hall  

Computer Number:Computer 108  

Novel calibration-free correction of field inhomogeneity artifacts in EPI using a structured low rank method

Author:Arvind Balachandrasekaran  Merry Mani  Mathews Jacob  

Institution:University of Iowa  

Session Type:Digital Poster  

Session Date:Thursday, 16 May 2019  

Session Time:09:15  

Session Name:Artifacts, Implants & Corrections  

Program Number:4599  

Presentation Time:

Room Number:Exhibition Hall  

Computer Number:Computer 55  

SMS-MUSSELS: A Navigator-free Reconstruction for Slice-accelerated Multi-shot Diffusion Imaging

Author:Merry Mani  Mathews Jacob  Graeme McKinnon  Baolian Yang  Brian Rutt  Adam Kerr  Vincent Magnotta  

Institution:Ge Healthcare  GE Healthcare  Stanford University  University of Iowa  

Session Type:Power Pitch  

Session Date:Monday, 13 May 2019  

Session Time:16:00  

Session Name:Pitch: Diffusion MRI: Acquisition, Reconstruction & Artefact Correction  

Program Number:0233  

Presentation Time:16:00   

Room Number:Power Pitch Theater A - Exhibition Hall  

Computer Number:

SMS-MUSSELS: A Navigator-free Reconstruction for Slice-accelerated Multi-shot Diffusion Imaging

Author:Merry Mani  Mathews Jacob  Graeme McKinnon  Baolian Yang  Brian Rutt  Adam Kerr  Vincent Magnotta  

Institution:Ge Healthcare  GE Healthcare  Stanford University  University of Iowa  

Session Type:Power Pitch Poster  

Session Date:Monday, 13 May 2019  

Session Time:17:00  

Session Name:Poster: Diffusion MRI: Acquisition, Reconstruction & Artefact Correction  

Program Number:0233  

Presentation Time:17:00   

Room Number:Power Pitch Theater A - Exhibition Hall  

Computer Number:Plasma 12  

Total suicide attempts associated with distinct functional neuroimaging correlates in bipolar disorder

Author:Joseph Shaffer  Virginia Willour  Casey Johnson  Jeffrey Long  Jess Fiedorowicz  Gary Christensen  John Wemmie  Vincent Magnotta  

Institution:University of Iowa  

Session Type:Combined Educational & Scientific Session  

Session Date:Wednesday, 15 May 2019  

Session Time:08:15  

Session Name:Psychoradiology for Neuropsychiatric Disorders  

Program Number:0713  

Presentation Time:09:30   

Room Number:Room 513D-F  

Computer Number: